POLITEC s.r.l. | Manual PARVIS HYBRID SMA – Ver. 1.2
15
9.
SETTINGS & FUNCTIONS
DIP SWITCHES
The board has Dip Switches to set different functions:
4 DIP SWITCH TX
1
TEST
In ON position goes in test for alignment. The TEST LED start blinking.
2
/
Not utilized
3
BEAM ON
It puts in test all TX during alignment (DIP 1 ON). Test LED fixed ON.
4
BEAM OFF
It puts OFF all TX during alignment (DIP 1 ON). Test LED fixed ON.
ON
1
2
3
4
5
6
7
8
9
10
Ex.: Function AND 1-2 with 6 beams
10 DIP SWITCHES RX
1
AND
At least 2 optical must be interrupted to give alarm
2
AND 1-2
AND function only for 1st and 2nd beam, usefull in case of growing grass
3
BEAM 3
First 3 RX are active
4
BEAM 4
First 4 RX are active
5
BEAM 5
First 5 RX are active
6
BEAM 6
all RX are active
7
S. LOW
FOG disqualification active
8
A. CRAWL
ON
- Anti crawling active. In this condition if the first beam (lower) is interrupted for
more than 2 seconds, it will generate an alarm, independently of its configuration
(i.e. AND)
9
AMK
/
10
TEST
Put in ON to activate the TEST