Connections and circuit descriptions TX
•
The power connector is linked to power supplier via a flat cable.
•
The connectors "MW" or Output 1 / 2 are used to connect the cavity
transmission. Normally uses the output "Output 1", and only in case of
double barrier microwave using the synchronized output "Output 2".
•
The "Led insert jumpers", inserted in position 2-3, enables the power of Led
Output "and" Led VDC ", indicating the presence of their tensions. Return
after the test at rest 1-2. NB The "Output LED" has a lower light intensity of
Led VDC, when the cavity "TX" is inserted.
•
The "channel selector" allows you to select the desired channel by switching
to "ON".
NB The selected channel must be the same as that of the Circuit "Rx”.
1 2 3 4
"
channel
selector"
“Led
Output”
“Led Vd”
(power)
“Led insert
jumpers”
(Output,
Vdc)
“Power
connector”
“MW”
Connectors:
Output 1
Output 2
POLITEC s.r.l.
1
2
3
ON
“Tamper
connector”