background image

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Microwave barrier for perimeter 
protection at long range. 
Installation manual . 

 

POLITEC s.r.l.

 

Содержание MANA MW 25

Страница 1: ...Microwave barrier for perimeter protection at long range Installation manual POLITEC s r l...

Страница 2: ...___________________________________________________________________ ________________________________________________________________________________ ___________________________________________________...

Страница 3: ...ms Page 8 Possible correction of incorrect positioning Page 9 Connections TX Page 10 Connections RX Page 12 Connections power supplier Page 15 Connections and descriptions cavity Tx and Rx Page 17 Con...

Страница 4: ...10 4 6 8 7 9 11 5 N Parts Quantity Description 1 1 Top Cap 2 1 Aluminium Profile 3 2 Aluminium inserts 4 1 IR cover 5 1 Parable Mana 6 1 Illuminator Mana 7 1 Cavity Tx or Rx 8 2 Handling system 9 1 P...

Страница 5: ...the cable ducting and conduit and secondly as a hold solid base to mount the beam tower Single cable pit side panel Assembled cable pit ensure that the mounting flange is uppermost Use the supplied n...

Страница 6: ...ble pit Once fully assembled the cable pit is installed ten centimeters below ground level and is embedded in concrete once correctly installed it can be covered with turf or suitable decking so that...

Страница 7: ...justments to make the beam sit perfectly vertically can be made via inserts in the top face of the cable pit flange Underscrewing the insert raises it thus raising the base of the tower on that side a...

Страница 8: ...nt sections are annulled should at the vertices of the polygon cross resulting from the installation of the various sections be installed two equipment with the same name two transmitters or two recei...

Страница 9: ...m shouldn t be placed in parallel to a metallic fence is necessary to create a corner with it Metal fences placed behind the equipment night cause distorsions to the sensitive beam especially and migh...

Страница 10: ...rted in position 2 3 enables the power of Led Output and Led VDC indicating the presence of their tensions Return after the test at rest 1 2 NB The Output LED has a lower light intensity of Led VDC wh...

Страница 11: ...11 POLITEC s r l Connections TX TO CAVITY TX 24 5 GHz CONTACT TAMPER NC POWER INFRARED BARRIER POWER SUPPLIER HEATER BATTERY 12V TO OTHER HEATERS LAND 230V LAND TRANSFORMER TX...

Страница 12: ...el selector Funciones selector Delay Led Alarm Led Channel Potentiometer Walk Test 4 3 2 1 1 Insert LED bar for Test Alignment 2 Display on LED bar signal Rx strength 3 Disconnect CAG automatic gain c...

Страница 13: ...ted channel must be the same as that of the Circuit Tx The Channel LED indicates that the channel is tuned with the transmitter The LED Alarm indicates that the system is not in alarm when there is th...

Страница 14: ...POLITEC s r l 14 Cablaggi Barriera RX TO CAVITY TX 24 5 GHz POWER INFRARED BARRIER CONTACT TAMPER NC CONTACT ALARM NC POWER SUPPLIER HEATER TO OTHER HEATERS BATTERY 12V LAND 230V LAND TRANSFORMER...

Страница 15: ...be connected to the transformer 7 8 24 VAC output to connect the heaters Power Connector Circuit Tx or Rx is to be connected with flat cable to the power connector board Tx or Rx Power Connector Circu...

Страница 16: ...board is powered by the transformer while it is off if the battery involved Jumper 0 5 A battery Insert jumper when using more than 5 Ah batteries NB Current limit for battery charging 0 5 A Without...

Страница 17: ...Rx The switch located on the cavity Tx and Rx is positioned to OFF only after installation and after giving voltage to the columns The ON position the active protection of the receiver cavity by elec...

Страница 18: ...r used must have the following characteristics Primary voltage 230 V Secondary voltage 18 o 19 V 1 A Secondary voltage 24 V 6 A Minimum power 160 VA NB Use only safety transformers with a certificate...

Страница 19: ...Alarm The outputs of the devices consist of relay contacts normally closed for reporting states and tampering alarm The contact output to alarm consists of a static relay with a range from 12V 1A Tam...

Страница 20: ...rea of diameter at half length as a function of total distance and sensitivity NB remember to adjust the sensitivity of MANA according to half width of the beams is desired As the threshold is higher...

Страница 21: ...tivity is set to the Rx circuit The recommended height for installation of a conventional type is approximately 70 cm from the center of the antenna to the ground with the sensitivity set to medium 0...

Страница 22: ...verify that LEDs output and VCC see page 10 6 Replace the two jumpers in the resting position Column Receiver After you remove the cover and shield make connections to the mains power transformer and...

Страница 23: ...n of the parabola RX Once the maximum orientate the parable TX 2 Goodness signal Turn OFF the switching of the selector functions 1 and 2 and ON the numbers 3 5 and 10 for the Voltmeter display the ga...

Страница 24: ...gh can cause false alarms conversely a too low can prevent the detection of the small intruders Turn ON the dips of the selector function Numbers 6 and 10 leaving all others to OFF In this manner is d...

Страница 25: ...di funzionamento 25 C 65 C Canali di modulazione MW 4 commutabili Modulazione ON OFF Regolazione di sensibilit Trimmer a bordo Continua Regolazione di ritardo Trimmer a bordo Continua Dimensioni Altez...

Страница 26: ...___________________________________________________________________ ________________________________________________________________________________ ___________________________________________________...

Страница 27: ...___________________________________________________________________ ________________________________________________________________________________ ___________________________________________________...

Страница 28: ...POLITEC s r l 28 POLITEC s r l Via Adda 66 68 20040 Bellusco Mi Italia Tel 39 0 39 6883019 r a Fax 39 0 39 6200471 www politecsrl it E mail info politecsrl it R 1 0...

Отзывы: