BATTERY REMOVAL / INSTALLATION
See Chapter 2 – Battery Removal, page 2.40 and Battery
Installation, page 2.41 procedures.
BATTERY OFF SEASON STORAGE
Whenever vehicle is not used for a period of three
months or more, remove the battery from the vehicle,
ensure that it's fully charged, and store it out of the sun in
a cool, dry place. Check battery voltage each month
during storage and recharge as needed to maintain a full
charge.
NOTE
Battery charge can be maintained by using a Polaris
battery tender or by charging once a month to make up
for self-discharge. Battery tenders can be left
connected to automatically charge the battery if voltage
drops below a pre-determined level.
BATTERY TESTING
Whenever a service complaint is related to either the
starting or charging systems, the battery should be
checked first.
The following are two tests which can easily be made on
a sealed Maintenance Free battery to determine its
condition: OCV Test and a Load Test.
OCV - OPEN CIRCUIT VOLTAGE TEST
Battery voltage should be checked with a digital
multitester. Readings of 12.6 volts or less require further
battery testing and charging. See the following chart and
“Load Test”.
NOTE
Maintenance Free batteries should be kept at a high
state of charge during storage. If the battery is stored or
used at a low state of charge, hard crystal sulfation will
form on the plates, reducing the efficiency and service
life of the battery.
Use a volt/ohm meter to test battery voltage.
OPEN CIRCUIT VOLTAGE
STATE OF CHARGE
VOLTAGE
100%
12.8 V and up
75% Charged
12.6 V
50% Charged
12.3 V
25% Charged
12.0 V
0% Charged
11.8 V or less
LOAD TEST
CAUTION
To prevent shock or component damage, remove spark
plug high tension leads and connect securely to engine
ground before proceeding.
A battery may indicate a full charge condition in the OCV
test, but still may not have the storage capacity
necessary to properly function in the electrical system.
For this reason, a battery capacity or load test should be
conducted
whenever
poor
battery
performance
is
encountered.
To perform this test, use a load testing device that has an
adjustable load. Apply a load of three times the ampere-
hour rating. At 14 seconds into the test, check battery
voltage. A good 12V battery will have at least 10.5 volts.
If the reading is low, charge the battery and retest.
BATTERY CONDUCTANCE ANALYZER
Conductance describes the ability of a battery to conduct
current. A conductance tester functions by sending a low
frequency AC signal through the battery and a portion of
the current response is captured, from this output a
conductance measurement is calculated. Conductance
testing is more accurate than voltage, specific gravity, or
load testing.
Authorized Polaris dealers/distributors are required to
use the conductance analyzer when testing 12V Polaris
batteries.
Polaris MDX-610P
PU-50296
Содержание RZR XP 1000 2014
Страница 4: ......
Страница 6: ......
Страница 199: ...4 9926816 R07 2014 2016 RZR XP 1000 XP4 1000 Service Manual Copyright Polaris Industries Inc 4 29 FUEL SYSTEM ...
Страница 350: ...7 46 9926816 R07 2014 2016 RZR XP 1000 XP4 1000 Service Manual Copyright Polaris Industries Inc NOTES FINAL DRIVE ...
Страница 446: ...9 38 9926816 R07 2014 2016 RZR XP 1000 XP4 1000 Service Manual Copyright Polaris Industries Inc NOTES BRAKE SYSTEM ...
Страница 474: ...10 28 9926816 R07 2014 2016 RZR XP 1000 XP4 1000 Service Manual Copyright Polaris Industries Inc NOTES BODY FRAME ...
Страница 523: ...11 9926816 R07 2014 2016 RZR XP 1000 XP4 1000 Service Manual Copyright Polaris Industries Inc 11 49 LIGHTS ELECTRICAL ...
Страница 531: ......
Страница 532: ......
Страница 533: ......
Страница 534: ......
Страница 535: ......
Страница 536: ......