9926816 R07 - 2014-2016
RZR
XP 1000 / XP4 1000 Service Manual
© Copyright Polaris Industries Inc.
4.45
COMPONENT
CONDITION
SPN
FMI
P-CODE
EPS Power Save Condition
EPS: Key On, Engine Off, 5 Minute
Power Save/Timeout
520231
31
C1071
Idle Air Control Valve (IAC)
M17; IAC Stepper Pin 3
Driver Circuit Short to B+
520268
3
P1519
Driver Circuit Grounded
4
P1518
Driver Circuit Open / Grounded
5
P1515
Mechanical System Not
Responding
7
P1559
Out Of Calibration
13
P1302
Idle Air Control Valve (IAC)
M17; IAC Stepper Pin 4
Driver Circuit Short to B+
520269
3
P1529
Driver Circuit Grounded
4
P1528
Driver Circuit Open / Grounded
5
P1525
Mechanical System Not
Responding
7
P1579
Out Of Calibration
13
P1303
Idle Air Control Valve (IAC)
M17; IAC Stepper Pin 6
Driver Circuit Short to B+
520270
3
P1539
Driver Circuit Grounded
4
P1538
Driver Circuit Open / Grounded
5
P1535
Mechanical System Not
Responding
7
P1589
Out Of Calibration
13
P1304
Idle Air Control Valve (IAC)
M17; IAC Stepper Pin 1
Driver Circuit Short to B+
520271
3
P1509
Driver Circuit Grounded
4
P1508
Driver Circuit Open / Grounded
5
P1505
Mechanical System Not
Responding
7
P1549
Out Of Calibration
13
P1301
Accelerator Position / Brake
Position Interaction
Condition Exists
520275
31
P150A
Throttle Position Sensor
(1 or 2 Indeterminable)
Position Sensor Correlation Fault
520276
2
P150C
Neither Position Sensor Passed
Test
12
P150B
Throttle Body Control - Power
Stage
Not Plausible
520277
2
P151A
Voltage Above Normal
3
P150D
Voltage Below Normal
4
P150E
Signal Error
8
P151B
Deactivated power stages due to
5V sensor supply error
31
P153F
Throttle Body Control - Return
Spring Check Failed
Condition Exists
520278
31
P151C
Throttle Body Control -
Adaptation Aborted
Condition Exists
520279
31
P151D
Throttle Body Control - Limp
Home Position Check Failed
Condition Exists
520280
31
P151E
Throttle Body Control -
Mechanical Stop Adaptation
Failure
Condition Exists
520281
31
P152A
Throttle Body Control -
Repeated Adaptation Failed
Condition Exists
520282
31
P152B
Содержание RZR XP 1000 2014
Страница 4: ......
Страница 6: ......
Страница 199: ...4 9926816 R07 2014 2016 RZR XP 1000 XP4 1000 Service Manual Copyright Polaris Industries Inc 4 29 FUEL SYSTEM ...
Страница 350: ...7 46 9926816 R07 2014 2016 RZR XP 1000 XP4 1000 Service Manual Copyright Polaris Industries Inc NOTES FINAL DRIVE ...
Страница 446: ...9 38 9926816 R07 2014 2016 RZR XP 1000 XP4 1000 Service Manual Copyright Polaris Industries Inc NOTES BRAKE SYSTEM ...
Страница 474: ...10 28 9926816 R07 2014 2016 RZR XP 1000 XP4 1000 Service Manual Copyright Polaris Industries Inc NOTES BODY FRAME ...
Страница 523: ...11 9926816 R07 2014 2016 RZR XP 1000 XP4 1000 Service Manual Copyright Polaris Industries Inc 11 49 LIGHTS ELECTRICAL ...
Страница 531: ......
Страница 532: ......
Страница 533: ......
Страница 534: ......
Страница 535: ......
Страница 536: ......