![Polaris PWK 1774CGL Скачать руководство пользователя страница 19](http://html.mh-extra.com/html/polaris/pwk-1774cgl/pwk-1774cgl_operation-manual_1571906019.webp)
19
Switch on the kettle by pressing the ON/OFF (I/O) switch keys down. The internal light will turn on. Do not turn on the kettle without a lid.
The water will start boiling.
Attention!
If you accidentally turn on the kettle without water, the protection system will turn on and the ON/OFF switch will automatically return to the OFF
position
(O)
. Before using the kettle again, remove it from the power base and let it cool for 30 minutes, then fill it with cold water.
9.
Turning-off the Kettle
When the water boils the kettle will turn off automatically. The interior lightning will turn off.
If necessary, you can turn off the kettle manually by moving the ON/OFF switch button to the upper position.
It is not recommended to boil the same water twice.
Attention!
Do not remove the kettle from the base until it turns off.
If the kettle lid or the valve is defective the automatic shutdown will not work.
Pour the water out of the kettle gradually. Remember that there is boiling water inside.
Hold the kettle by the handle only.
After turning off the heating the kettle can be used again after 15-20 seconds.
7.
CLEANING AND CARE
8.
Unplug the kettle and let it cool.
9.
Wipe the kettle outside with a damp cloth.
Never immerse the kettle, cord, plug, or power base in water.
10.
Getting rid of limescale
Due to the salt content in the water limescale forms at the bottom and around the walls of the kettle. The presence of limescale and sediment must be
checked regularly and removed in a timely manner. If your kettle boils water for too long, turns off before boiling or makes excessive noise during operation
this means that it needs to be de-scaled. The appearance of limescale depends on the water hardness. De-scale the kettle at least 1 once a month.
To clean your kettle from limescale you can use a
citric acid solution
:
Mix 25 g of citric acid with 0.5 l of hot water.
Pour the liquid into the kettle.
Leave it on for 15 minutes.
Rinse the kettle with cold water two to three times.
Repeat cleaning if necessary.
To clean your kettle from limescale you can use a
dilute solution of vinegar
.
Dilute 2/3 of water and 1/3 of 6% vinegar.
Pour this solution into the kettle so that the heating element is covered, boil 2 - 3 times with 20-minute pauses.
Rinse the kettle with clean water two-three times and wipe it with a dry cloth.
Repeat cleaning if necessary.
You can also use a
special de-scaler
suitable for metal kettles. Follow manufacturer's recommendations.
Attention!
Never use aggressive or abrasive detergents to clean the kettle.
When using a descaling powder, always add water as recommended by the powder manufacturer. Never use these products without water.
Perform all loading/unloading/washing operations only with the kettle disconnected from the grid.
11.
ilter Cleaning
Disconnect the base from the grid and remove the kettle from the base. Pour out the remaining water. Cool the kettle if it is hot.
Open the kettle lid.
Gently pull the filter towards you by the tab with the arrow, remove it from the slot and place it under a low stream of water. Use a soft brush to remove dirt (not
included). Rinse with water.
Place the cleaned filter in the grooves inside the nose (as described in Section 5 hereof).
Attention!
!
Do not remove the filter if there is hot water in the kettle.
Over time, the kettle's heating element may change colour due to intense heating. This is a normal occurrence, and the kettle can be used further.
8.
STORAGE
Electrical devices are stored in a closed, dry and clean room at an ambient temperature of no higher than 40 °C with relative humidity not higher than 70%
and no dust, acid or other vapours in the environment that negatively affect the materials of the electrical device.
9.
TRANSPORTATION
Electrical devices are transported by all means of transport in accordance with the rules for that particular type of carriage of goods in place on a particular type of
transport. When transporting the device, use the original factory packaging.
Transportation of devices should exclude the possibility of direct exposure to atmospheric precipitation and aggressive environments.
10.
SALES
Sales rules have not been established.
11.
DISPOSAL REQUIREMENTS
Waste generated during the disposal of products is subject to mandatory collection and subsequent disposal in the prescribed manner and in accordance with
applicable requirements and norms of industry normative documentation, including in accordance with Sanitary Regulations and Norms 2.1.7.1322-03 “Hygienic
Requirements for the Placement and Disposal of Production and Consumption Waste."
12.
TROUBLESHOOTING
Problem
Possible cause
Troubleshooting
The kettle turns off before the water boils
Limescale forms on the heating element
De-scale the kettle as recommended in section 5.
Cleaning and Care
The kettle does not turn on
The power outlet does not work
Connect the kettle to another outlet
The power cord is damaged
For repair or replacement, contact an authorized
service centre.
Plug the power cord into a power outlet.