DP-20 WEB GUIDE CONTROLLER USER MANUAL
9
9-3
EEPROM WRITE
fault (007). An error was detected while writting to
the EEPROM. Press the ENTER key to exit the fault screen. Repeat
the last performed procedure. If the fault persists, the unit must be
repaired.
WATCHDOG RESET
fault (008). An unexpected watchdog reset was
detected. XX at the left end of line 1 is a code that indicates the
source of the fault. Press the ENTER key to exit the fault screen and
continue using the unit. If the fault persists, the unit must be repaired.
EXTERNAL DAC
fault (009). This fault may occur during Sensor
Calibration. Press the ENTER key to exit the fault screen. Repeat the
last performed procedure. If the fault persists, the unit must be
repaired.
MEMORY ALLOC.
fault (010). This indicates that a Memory
Allocation error has occurred. Press the ENTER key to exit the fault
screen. Cycle the power to the unit. If the fault persists, the unit must
be repaired.
EEPROM BUSY
fault (011). This fault indicates that the EEPROM
was busy when a memory write was attempted. Press the ENTER
key to exit the fault screen. Repeat the last performed procedure. If
the fault persists, the unit must be repaired.
3A.0.007
<<< FAULT >>>
EEPROM WRITE
PRESS èéê
XX 3A.0.008
<<< FAULT >>>
WATCHDOG RESET
PRESS èéê
3A.0.009
<<< FAULT >>>
EXTERNAL DAC
PRESS èéê
3A.0.010
<<< FAULT >>>
MEMORY ALLOC.
PRESS èéê
3A.0.011
<<< FAULT >>>
EEPROM BUSY
PRESS èéê
Return Shipment Instructions
If it is necessary to return the Polaris DP-20 to Fife Corporation for service, care must be taken
to properly package the unit to prevent damage during shipment. Pay particular attention to the
power receptacle on the rear panel of the unit. If the rubber cover for the power receptacle was
kept from the original receipt of the unit, place it over the power receptacle to protect the
protruding pins. If the rubber cover is not available, place sufficient packing material around the
power receptacle to protect it during shipment.
06-05-2007
DP-20 WEB GUIDE CONTROLLER
Figure Sheet 1-862-D
Содержание DP-20
Страница 2: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...
Страница 4: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...
Страница 8: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...
Страница 22: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...
Страница 58: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...
Страница 60: ...06 05 2007 DP 20 WEB GUIDE CONTROLLER Figure Sheet 1 862 D THIS PAGE INTENTIONALY LEFT BLANK ...