11.4
BATTERY & ELECTRICAL SYSTEMS
CONVENTIONAL BATTERY
NOTE: Do not service the battery unless it will be
put into regular service within 30 days.
Battery Preparation
1.
Fill battery with electrolyte to the upper level marks on the
case.
2.
Set battery aside and allow it to cool and stabilize for at least
30 minutes.
3.
Add electrolyte to bring the level back to the upper level
mark on the case.
NOTE: This is the last time electrolyte is added.
After charging the battery, only add distilled water.
4.
Charge battery at 1/10 of its amp/hour rating. Example:1/
10 of 9 amp battery =.9 amps, 1/10 of 14 amp battery = 1.4
amps, 1/10 of 18 amp battery = 1.8 amps (recommended
charging rates).
5.
Check specific gravity of each cell with a hydrometer to
ensure each has a reading of 1.270 or higher.
6.
Install vent covers.
Specifications
Refilling a Conventional Battery
The normal charge/discharge cycle of a battery causes the cells
to give off gases. These gases, hydrogen and oxygen, are the
components of water. Because of the loss of these gases and the
lowering of the electrolyte level, it will be necessary to add pure,
clean distilled water to bring the fluid to the proper level. After
filling, charge the battery to raise the specific gravity to 1.270 or
greater.
FRESH PACK BATTERY
NOTE: Do not service the battery unless it will be
put into regular service within 30 days.
Battery Preparation
Some models are equipped with a fresh pack battery. These
batteries require filling with electrolyte and a full charge prior to
service.
1.
Fill battery with electrolyte to the upper level marks on the
case.
2.
Set battery aside and allow it to cool and stabilize for at least
30 minutes.
3.
Add electrolyte to bring the level back to the upper level
mark on the case.
NOTE: This is the last time that electrolyte should
be added.
4.
Charge battery at 1/10 of its amp/hour rating. Example:1/
10 of 9 amp battery =.9 amps, 1/10 of 14 amp battery = 1.4
amps, 1/10 of 18 amp battery = 1.8 amps (recommended
charging rates).
5.
Check specific gravity of each cell with a hydrometer to
ensure each has a reading of 1.270 or higher.
6.
Install vent cover.
NOTE: Once the vent cover is installed, the battery
is sealed. Do not remove the cover.
Specifications
Battery PN 4140006
Battery Type
YB14A-A2 - Conventional
Nominal Capacity
12Vdc / 14AH
Electrolyte Volume
30.4oz.
CCA @ 0F (-18C)
195 AMPS
Charging Current
1.4 AMPS
Battery PN 4140005
Battery Type
Y50-N18L-A - Conventional
Nominal Capacity
12Vdc / 20AH
Electrolyte Volume
47.3oz.
Charging Current
2 AMPS
Battery PN 4011092 (4010905)
Battery Type
YTX14AH-BS-Fresh Pack
Nominal Capacity
12Vdc / 12AH
Electrolyte Volume
22.3oz.
Specific Gravity
1.320
CCA @ 0F (-18C)
210 AMPS
Charging Current
1.2 AMPS
Содержание 340 LX 2007
Страница 4: ......
Страница 40: ...NOTES MODEL SPECIFICATIONS 1 36...
Страница 51: ...2 11 GENERAL 2 SPECIAL TOOLS Special Tools...
Страница 52: ...2 12 GENERAL...
Страница 53: ...2 13 GENERAL 2...
Страница 54: ...2 14 GENERAL...
Страница 80: ...NOTES MAINTENANCE 3 26...
Страница 91: ...4 11 FUEL DELIVERY 4 Throttle Opening Vs Fuel Flow VM only...
Страница 104: ...NOTES FUEL DELIVERY 4 24...
Страница 114: ...5 10 ENGINE 500 600 Touring WideTrak LX Touring WideTrak...
Страница 146: ...NOTES ENGINE 5 42...
Страница 170: ...NOTES CLUTCHING 6 24...
Страница 214: ...NOTES FRONT SUSPENSION STEERING 8 20...
Страница 259: ...10 11 CHASSIS HOOD 10...
Страница 260: ...NOTES CHASSIS HOOD 10 12...
Страница 272: ...11 12 BATTERY ELECTRICAL SYSTEMS ELECTRIC START GEN II EDGE System Schematic...
Страница 276: ...11 16 BATTERY ELECTRICAL SYSTEMS ELECTRIC START IQ CARBURETED CFI System Schematic 600 HO Carbureted...
Страница 277: ...11 17 BATTERY ELECTRICAL SYSTEMS 11 System Schematic 600 700 CFI...
Страница 286: ...11 26 BATTERY ELECTRICAL SYSTEMS Chassis Relay...
Страница 288: ...11 28 BATTERY ELECTRICAL SYSTEMS Vehicle Speed Sensor...
Страница 293: ...11 33 BATTERY ELECTRICAL SYSTEMS 11 CFI Power System CFI Ignition Injection Power...
Страница 294: ...11 34 BATTERY ELECTRICAL SYSTEMS CFI Crank Position System CFI Safety Stop System...
Страница 295: ...11 35 BATTERY ELECTRICAL SYSTEMS 11 CFI Full Load Fuel Injectors CFI Part Load Fuel Injectors...
Страница 296: ...11 36 BATTERY ELECTRICAL SYSTEMS CFI Chassis Power CFI Ignition Coils...
Страница 297: ...11 37 BATTERY ELECTRICAL SYSTEMS 11 CFI TBAP Sensor CFI TPS Engine Temp Sensors...
Страница 298: ...11 38 BATTERY ELECTRICAL SYSTEMS CFI Exhaust Solenoid CFI Knock Sensor...
Страница 299: ...11 39 BATTERY ELECTRICAL SYSTEMS 11 CFI Fuel Pump CFI Diagnostic Connections...
Страница 300: ...11 40 BATTERY ELECTRICAL SYSTEMS CFI MFD Circuits CFI MFD Power Circuits...
Страница 301: ...11 41 BATTERY ELECTRICAL SYSTEMS 11 CFI Fuel Level Circuit CFI Vehicle Speed Circuit...
Страница 302: ...11 42 BATTERY ELECTRICAL SYSTEMS CFI Mode Set Switch CFI PERC Switch...
Страница 318: ...12 1 Wiring Diagrams 2007 340 550 GEN II EDGE Models...
Страница 319: ...12 2 Wiring Diagrams 2007 Wide Trak...
Страница 320: ...12 3 Wiring Diagrams 2007 500 XCSP...
Страница 321: ...12 4 Wiring Diagrams 2007 600 HO Carbureted 1 of 2...
Страница 322: ...12 5 Wiring Diagrams 2007 600 HO Carbureted 2 of 2...
Страница 323: ...12 6 Wiring Diagrams 2007 600 HO Carbureted Hood Harness...
Страница 324: ...12 7 Wiring Diagrams 2007 600 700 CFI 1 of 2...
Страница 325: ...12 8 Wiring Diagrams 2007 600 700 CFI 2 of 2...
Страница 327: ...12 10 Wiring Diagrams...