Troubleshooting
If your POLAR appliance develops a fault, please check the following table before making a call to the Helpline or your POLAR dealer.
Technical Specifications
Electrical Wiring
.
The plug is to be connected to a suitable mains socket.
POLAR appliances are wired as follows:
•
Live wire (coloured brown) to terminal marked L
•
Neutral wire (coloured blue) to terminal marked N
•
Earth wire (coloured green/yellow) to terminal marked E
All POLAR appliances must be earthed, using a dedicated earthing circuit.
If in doubt consult a qualified electrician.
Electrical isolation points must be kept clear of any obstructions. In the event of any emergency disconnection being required they must be readily accessible.
Fault
Probable Cause
Action
The appliance is not working
The unit is not switched on
Check the unit is plugged in correctly and switched on
Plug and lead are damaged
Call POLAR agent or qualified Technician
Fuse in the plug has blown
Replace the fuse
Power supply
Check power supply
Internal wiring fault
Call POLAR agent or qualified Technician
The appliance turns on, but the
temperature is too high/low
Too much ice on the evaporator
Defrost the appliance
Condenser blocked with dust
Clean condenser with hose attachement of vacuum
Doors are not shut properly
Check doors are shut and seals are not damaged
Appliance is located near a heat source or air flow to
the condenser is being interrupted
Move the refrigerator to a more suitable location
Ambient temperature is too high
Increase ventilation or move appliance to a cooler position
Unsuitable foodstuffs are being stored in the
appliance
Remove any excessive hot foodstuffs or blockages to the fan
Appliance is overloaded
Reduce the amount of food stored in the appliance
The appliance is leaking water
The appliance is not properly levelled
Adjust the screw feet to level the appliance (if applicable)
The discharge outlet is blocked
Clear the discharge outlet
Movement of water to the drain is obstructed
Clear the floor of the appliance (if applicable)
The water container is damaged
Call POLAR agent or qualified Technician
The drip tray is overflowing
Empty the drip tray (if applicable)
The appliance is unusually loud
The safety band has not been removed
Remove the safety band
Loose nut/screw
Check and tighten all nuts and screws
The appliance has not been installed in a level or
stable position
Check installation position and change if necessary
Model
Voltage
Power
Current
Temperature
Range
Capacity
(litres)
Refrigerant
Dimensions
H x W x D (mm)
Weight
(kg)
DL893-A
220-240V 50Hz
380
2.3A
-2°C to 10°C
600
R134a 300g
2010 x 680 x 850
145
DL894-A
220-240V 50Hz
600
2.8A
-15°C to -22°C
600
R404a 360g
2010 x 680 x 850
148
DL895-A
220-240V 50Hz
700
3.3A
-2°C to 10°C
1200
R134a 320g
2010 x 1340 x 850
195
DL896-A
220-240V 50Hz
700
3.3A
-15°C to -22°C
1200
R404a 450g
2010 x 1340 x 850
198
DL897-A
220-240V 50Hz
700
3.3A
-15°C to -22°C
1200
R404a 450g
2010 x 1340 x 850
198
DL898-A
220-240V 50Hz
700
3.3A
-2°C to 10°C
1200
R134a 320g
2010 x 1340 x 850
195
DL899-A
220-240V 50Hz
380
2.3A
-2°C to 10°C
600
R134a 300g
2010 x 680 x 850
145
CK480-A
220-240V 50Hz
600
2.8A
-15°C to -22°C
600
R404a 360g
2010 x 680 x 850
148
Содержание DL893-A