CelloTrack LTE Plus Overview
CelloTrack LTE Plus Overview.docx Page 20 of 39
Copyright © 2019 by Pointer Telocation, Ltd.
4.3
User Features
4.3.1
Activation
When the unit is not active, upon pressing the front button for 5 seconds (long press),
the unit is activated. The SYS LED lights for 5 seconds in
Green
, to indicate the user
that the unit is active. The COMM LED performs 10 GSM/GPS indication cycles, and
then is shut off.
Note that after battery replacement, the unit shall be automatically activated, i.e. with
no need of activation by button as described above. After automatic activation, the
SYS LED behaves as described above.
------------------------------------------------------------------------------------------------
NOTE:
Consecutive presses are ignored, if started before the SYS LED indication of
the previous press/sequence ended.
------------------------------------------------------------------------------------------------
4.3.2
De-Activation
When the unit is active, upon pressing the front button for 5 seconds (long press), the
unit is de-activated. The SYS LED shall light for 5 seconds in
Red
, to indicate the user
that the unit is not active. In the case of enabled logged or distress events, the de-
activation is postponed until the events are transmitted (or until Modem Max On Time
expiration). In the postpone time, the SYS LED shall blink (200msec on every 1
second) in
Red
.
------------------------------------------------------------------------------------------------
NOTE:
Consecutive presses are ignored, if started before the SYS LED indication of
the previous press/sequence ended.
------------------------------------------------------------------------------------------------
4.3.3
Panic/Distress
When the unit is active, upon pressing the front button for a period of between 0 and 5
seconds (short press), a panic/distress press is recognized. The SYS LED then reflects
the battery SOH (State of Health):
If the SOH is above the preprogrammed minimum - the SYS LED lights for 2
seconds in
Green
.
If the SOH is below (or equal to) the preprogrammed minimum - the SYS LED
lights for 2 seconds in
Red
.
------------------------------------------------------------------------------------------------
NOTE:
Consecutive presses are ignored, if started before the SYS LED indication of
the previous press/sequence ended.
------------------------------------------------------------------------------------------------
4.3.4
Battery Status Manual Check
A maintenance operator can manually check the battery status.
For doing it, when the unit is active, the maintenance operator will perform
panic/distress press the front button for a period of between 0 and 5 seconds (short
press). The SYS LED shall than reflect the battery SOH (State of Health):
If the SOH is above the preprogrammed minimum - the SYS LED lights for 2
seconds in
Green
.