![PNI TCM2.5 Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/pni/tcm2-5/tcm2-5_manual_1569855032.webp)
Page 32 of 48
damping=
(Set Digital Damping)
Description
Enables or disables filtering of the output.
Syntax
damping=n<cr>
Output
:[Ennn]<cr><lf>
Valid Values
Input
Description
e
enable damping
d
disable damping (default setting)
Table 10: Valid
damping=
values
Example
damping=e<cr>
!enable damping
:<cr><lf>
Query Response
damping?
:damping=
Related Commands
timeconst=
(set time constant for digital damping)
ec=
(Enable Compass Data for Output Word)
Description
Enables or disables compass data for inclusion in the TCM2.5/2.6 Standard Output Word.
Syntax
ec=n<cr>
Output
:[Ennn]<cr><lf>