Auto Sync System
This seldom needs adjusting after the initial setup if the rest of the system is well
maintained.
Note: Do not adjust the Auto Sync components to compensate for problems elsewhere in
the CAFS system.
Before you make any adjustments, make sure the oil level in the sump is correct, the
air and oil filters are not overdue for servicing, the oil is not overdue for changing, the
compressor is not overheating, the oil cooler strainer is clean, and the air lines do not
have leaks.
Always start by adjusting UNLOAD mode, then FIXED, then AUTO.
A common problem is unauthorized adjustment of the balance valve in an attempt to
improve performance. If unauthorized adjustments to the Auto Sync are a problem we
suggest placing a seal over the adjustment points. This will let maintenance personnel
know if the system has been tampered with.
Auto Sync
1. UNLOAD Mode
1. Set the controls on the Auto Sync control panel to FIXED and UNLOAD. (UNLOAD for
electric valves)
Manual Valve Control
Electric Valve Control
2. Close all air discharges.
3. Locate the Air Inlet Trim Valve (AITV), near the air inlet on the compressor.
Содержание 120-60-DS
Страница 30: ...CAFS DS Series Installation Guide Page 30 of 40 Modules 120 60 DS Top Side Front...
Страница 31: ...CAFS DS Series Installation Guide Page 31 of 40 120 60 DS Mounting Tab Spacing 120 60 DS Mounting Tabs...
Страница 32: ...CAFS DS Series Installation Guide Page 32 of 40 250 120 DS...
Страница 33: ...CAFS DS Series Installation Guide Page 33 of 40 250 120 DS Mounting Tab Spacing 250 120 DS Mounting Tabs...
Страница 34: ...CAFS DS Series Installation Guide Page 34 of 40 Schematics Basic Compressed Air Foam System CAFS Schematic...
Страница 36: ...CAFS DS Series Installation Guide Page 36 of 40 120 60 Hydraulic Flow...
Страница 37: ...CAFS DS Series Installation Guide Page 37 of 40 Auto Sync Wiring Schematic electric...
Страница 38: ...CAFS DS Series Installation Guide Page 38 of 40 Auto Sync Air Schematic electric...
Страница 39: ...CAFS DS Series Installation Guide Page 39 of 40 Auto Sync Air Schematic manual...