TROUBLESHOOTING GUIDE:

Should an obvious problem occur with your cooler consult the following table. If you cannot correct the problem, or if it persists, 
contact qualified service personnel.

PROBLEM / SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

Water draining from unit

Float valve out of adjustment

Adjust float to 2-1/2" water depth

Float movement obstructed

Free float from obstruction

Float valve non-functional

Replace float assembly

Dry pads

Pump intake clogged

Remove obstruction

Water pump non-functional

Replace water pump

Clogged water line

Locate and free obstruction

Pad trough clogged

Clear debris from trough

Switch non-functional

Replace switch

Wiring non-functional

Repair or replace non-functional wiring

Water turned off to cooler

Turn on water supply

No water

Fill reservoir

Motor does not start or no air 
delivery

Electrical power disconnected

Check power receptacle and cord

Defective motor

Replace motor

Defective switch

Replace switch

Inadequate air delivery

Pads plugged

Replace pads

Motor cycles on & off

Low voltage

Check voltage

Blower shaft tight or locked

Oil or replace motor

Bearing dry

Oil bearings

Pad frame(s) or air outlet grille removed

Re-install pad frame(s) or air outlet grille

Noisy operation

Blower rubbing on housing

Reposition wheel

B

lower set screws loose

Tighten set screws

Musty or unpleasant odor

Stale or stagnant water in cooler

Drain, clean, and flush reservoir

Media pads clogged or mildewed

Replace media pads

Media pads not completely wet before starting 
fan motor

Turn pump ON for several minutes prior to starting 
cooler

New pads have an odor that goes away after 
about 4-8 hours.

Drain reservoir multiple times until odor dissipates

WIRING DIAGRAM

Содержание Master Blaster MB8

Страница 1: ...te this blower fan motor with any solid state speed control device Do NOT operate this unit with pad frame s and or air outlet grille removed this may cause the fan motor to overload and damage the mo...

Страница 2: ...4 20 bolts from the parts bag to secure all 4 of the casters to their respective caster plates Apply brakes before lifting cooler upright to complete assembly 2 Master Blaster Use and Care Manual PRE...

Страница 3: ...ts The motor and or pump can restart automatically when they cool down To verify and check out the cooler installation on initial start up the following procedure should be followed Push PUMP switch t...

Страница 4: ...CAUTION Disconnect all electrical power to the cooler before attempting to install open or service your cooler CAUTION Do not allow pump to fall over and become submerged water will damage pump motor...

Страница 5: ...p cooling pads will not work and will void your warranty 5 Lay new rigid media pads into the louver panel assy paying attention to how the slit at the bottom of the pad is oriented 6 Return the rigid...

Страница 6: ...off to cooler Turn on water supply No water Fill reservoir Motor does not start or no air delivery Electrical power disconnected Check power receptacle and cord Defective motor Replace motor Defective...

Страница 7: ...73 5 SWITCH BOX ASSEMBLY 05 007 0214 5a SWITCH PUMP 05 007 0147 5b SWITCH FAN 05 007 0148 5d SWITCH COVER 05 007 0215 6 POWER SUPPLY CORD 05 007 0186 7 CASTER COMPLETE SET OF 4 05 001 0152 8 FLOAT VAL...

Страница 8: ...other rights which vary from state to state Garantia Limitada Enfriador Evaporativo Phoenix Manufacturing Inc Phoenix Arizona extiende esta garant a limitada al comprador original de este enfriador e...

Отзывы: