   CAUTION:

This cooler is designed for connection to 120 volt AC, 60 Hz 
(cycle) power only. NOTE: Improper voltage will void the pump 
and/or motor warranties and may cause serious personal injury 
or property damage. 

This cooler is equipped with a power cord having equipment 
grounding conductor and grounding plug. Do NOT attempt to 
defeat this safety device by removing the grounding pin.

Master Blaster Use and Care Manual   3

OPERATING INSTRUCTIONS

Guidelines and location

 

Always make sure that the roll-around unit is operated on a solid, 
level surface strong enough to hold its weight (unit can weigh 270 
lbs when full). Make sure the two locking casters have been locked 
to prevent the cooler from accidentally moving while in use. Use 
caution when rolling the unit to avoid splashing or spilling of water. 
Unless the move is for a short distance, it is best to drain the unit, 
move it and then refill it in its new location.

 

Controls

 

Rocker-type control switches are used

 

to select the operating

 

mode of the

 

cooler. These switches control fan

 

speed (FAN-HIGH/

OFF/LOW) and the

 

pump operation (

PUMP

-ON/OFF). 

To eliminate a rush of warm air when

 

starting the cooler, be sure to 

turn the

 

pump on for a few minutes

 

before turning on the blower 

motor (FAN) in low or high speed.

GENERAL INSPECTION

Pre-Start-up Inspection Checklist

 

Before start-up of the cooler motor and pump for the first time, or 
at the beginning of each cooling season, make sure all connections 
and adjustments have been made. 

Cooler is on a level surface, casters locked to prevent unnessary

movement (prevent spillage).

√ Power supply cord is plugged into a GFCI protected receptacle;

cord is secure from accidental damage.

√ Drain and float valve installed.
√ Water hose connected securely without leaks.
√ Water faucet or supply is turned on.
√ Float adjusted for proper water level.
√ Pad frames and air outlet grille correctly installed.
√ Pump impeller turns freely. Remove impeller cover (see

"Cleaning Pump"), and check rotation.

√ Blower wheel, shaft, pulley and motor sheave set bolts/screws

are snug.

√ Motor sheave/Blower pulley alignment is okay; belt tension is

okay.

   

CAUTION:

Never operate unit with pad frame(s) and/or air outlet grille 
removed. This will result in an overloaded condition and may 
damage the fan motor. The motor and pump have an internal 
automatic thermal overload switch that will shut the motor and/
or the pump off if it overheats! The motor and/or pump can 
restart automatically when they cool down. 

To verify and check out the cooler installation on initial start-up, the 
following procedure should be followed. 

Push “

PUMP

” switch to ON position (pump on).

Verify that pump starts and pads are evenly wet.

Push “FAN” switch to LOW position (low speed on).

Observe that motor starts and runs. Check high-speed function by

turning “FAN” switch to HIGH (high speed on).

When switching from Low to Hi speed you should pause in center

position (OFF) for 2 seconds to extend motor life.

NOTE: When new, the glue in the media pad may emit an odor. 
Flushing the pad and draining the water prior to first use can 
reduce or eliminate the odor.  Turn the pump on (do not turn on 
the fan) and run for approx. 30 minutes making sure the pad is 
soaked.  Remove standpipe & cap and drain the water out of the 
cooler.  Refill and run the pump again for another 30 minutes.   
The odor should diminish and go away.  If not, drain and flush 
until the od

o

r is gone.

Cabinet Inspection Checklist

 

After initial start-up and during periodic inspections, check for and/
or observe the following: Refer to the Troubleshooting Chart on 
page 6 if necessary. 

Leaks from water lines, pad frames, cabinet, etc.

Observe cooler pads for uneven wetting.

Confirm water level setting is correct.

Verify full, even flow in water distribution system.

Blower wheel / motor rotates freely.

Check that set screws on blower wheel are tight.

Check motor mounting and cabinet hardware.

Regular maintenance and periodic inspection is the key to long and

 

successful service of your Master Blaster cooler. The cooler should

 

receive major servicing at least once a year, more often if conditions

 

require (dusty environment, constant use, poor water quality, etc.) For

 

maximum cooling efficiency, long life and appearance, every two

 

months during operation, the cooler should be inspected and 
cleaned. 

NOTE: Do Not Undercoat the Water Reservoir 

Your cooler's water reservoir is finished with our Peblar XT® 
appliance-type finish. It is so hard that asphalt-type cooler water 
pan under-coatings will not stick to it. Undercoating will break free, 
clogging the pump and water distribution system. 

NOTE:

 Do not use cooler cleaners, cooler treatments, anodes or 

other chemical additives in this evaporative cooler. Use of any 
additives or water treatment other than the bleed-off will void your 
warranty and may impair the life of the cooler. 

Before starting any maintenance operation, thoroughly 
read all operating and maintenance instructions and 
observe all cautions and warnings.

MAINTENANCE SCHEDULE

START-UP CHECKLIST

Содержание Master Blaster MB8

Страница 1: ...te this blower fan motor with any solid state speed control device Do NOT operate this unit with pad frame s and or air outlet grille removed this may cause the fan motor to overload and damage the mo...

Страница 2: ...4 20 bolts from the parts bag to secure all 4 of the casters to their respective caster plates Apply brakes before lifting cooler upright to complete assembly 2 Master Blaster Use and Care Manual PRE...

Страница 3: ...ts The motor and or pump can restart automatically when they cool down To verify and check out the cooler installation on initial start up the following procedure should be followed Push PUMP switch t...

Страница 4: ...CAUTION Disconnect all electrical power to the cooler before attempting to install open or service your cooler CAUTION Do not allow pump to fall over and become submerged water will damage pump motor...

Страница 5: ...p cooling pads will not work and will void your warranty 5 Lay new rigid media pads into the louver panel assy paying attention to how the slit at the bottom of the pad is oriented 6 Return the rigid...

Страница 6: ...off to cooler Turn on water supply No water Fill reservoir Motor does not start or no air delivery Electrical power disconnected Check power receptacle and cord Defective motor Replace motor Defective...

Страница 7: ...73 5 SWITCH BOX ASSEMBLY 05 007 0214 5a SWITCH PUMP 05 007 0147 5b SWITCH FAN 05 007 0148 5d SWITCH COVER 05 007 0215 6 POWER SUPPLY CORD 05 007 0186 7 CASTER COMPLETE SET OF 4 05 001 0152 8 FLOAT VAL...

Страница 8: ...other rights which vary from state to state Garantia Limitada Enfriador Evaporativo Phoenix Manufacturing Inc Phoenix Arizona extiende esta garant a limitada al comprador original de este enfriador e...

Отзывы: