SPECIAL FUNCTIONS

Boost-Function

The boost function provides a short-term

increase of the set-point, e.g. with hot

runner control, in order to clear nozzles

of “frozen” rests of material.

Start-up circuit

For temperature control, e.g. with hot

runners. High-performance heating

elements with magnesium oxide

insulation must be heated slowly, to

remove any humidity and to prevent

destruction.

Modbus Master

The KS 90-1 can be configured as

Modbus Master. This enables it to

transmit user-specified signals or

parameters cyclically to all connected

Slave controllers. For example, the

following applications are possible:

Set-point shifting relative to the

set-point adjusted in the Slave (see

picture)

matching of control parameters, limit

contacts, etc.

Limiting the output value (override

control OVC)

...

LIMIT SIGNALLING FUNCTIONS

Max., Min. or Max./Min. monitoring with

adjustable hysteresis.

Signals which can be monitored:

Process value

Control deviation

Control deviation with suppression

during start-up or set-point changes

Effective set-point

Output signal Y

Control deviation always compared to

internal setpoint SP even if SP2 or

SP.E is activated.

Functions

Input signal monitoring

Input signal monitoring with latch

(reset via front key or digital input)

Adjustable discriminator time of

0...9999 seconds

Several limit signals or alarms can be

OR-linked before being output.

Applications: Release of a brake with

motor actuators, general alarms, etc.

ALARMS

Heating current alarm

Overload and short circuit

Open circuit and short circuit

Limit value adjustable 0...9999 A

Control loop alarm

Automatic detection if there is no

response of the process to a change of

output value.

Sensor break or short circuit

Depending on selected input type, the

input signal is monitored for break and

short circuit.

MAINTENANCE MANAGER

Display of error signals, warnings, and

latched limit messages in the error list.

Signals are latched, and can be reset

manually.
Possible signals in the error list:

Sensor break, short circuit, reversed polarity
Heating current alarm
Control loop alarm
Fault during self-tuning
latched limit messages
e.g. re-calibration warning

(If the adjusted operating hours are exceeded a

message is displayed)

e.g. maintenance interval of actuator

(If the adjusted switching cycles are exceeded a

message is displayed)

Internal fault (RAM, EEPROM, ...)

OPERATION AND DISPLAY

Display

Process value: LED with 7 segments, 10,5 mm
Lower display: LED with 7 segments, 7,8 mm

Operating functions

The functions of the

Ò

-key and the

è

-key are configurable:

Function

Ò è

Remote (no front operation)

X

SP.2 (2nd setpoint)

X

Y.2 (2nd output value)

X

X

SP.E (external setpoint)

X

X

Manual operation

X

X

C.OFF (controller function off)

X

X

Lock of manual key

X

Reset of latched limits and error list

X

X

Boost

X

Parameter set ½

X

Programmer run/stop

X

Several functions can be combined e.g.

SP.2 and parameter set switch-over

(gain scheduling) with only one key.

KS 50-1

5

KS 50-1

universal

1

2

3

OK

125

126

SP.X

run

Err

Ada

F

green “OK”-LED

process value
Programm run
selftuning is active
error list
setpoint, actuating value, parameter

Enter-key
operation keys

3 yellow LEDs for the output states

second or external setpoint

ramp is active

automatic/manual-key

configurable function-key

front interface

manual operation

BluePort

Display and operation:

125

126

SP.x

run

Ada
Err

Flashing Error LED indicates active alarm

in the error list:

Содержание KS 50-1

Страница 1: ...tion start up ensure increased lifetime of high performance electrical heating elements e g hot runner moulds Plug in module KS 50 1 controllers are built as plug in modules This enables them to be re...

Страница 2: ...stored in the controller Physical measuring range 0 4500 Linearization segments 16 2 KS 50 1 96 3 78 48 1 89 min 48 1 89 10 0 4 1 1 0 0 0 4 0 4 118 4 65 45 0 6 1 77 0 0 2 125 126 SP X run Err Ada 92 0...

Страница 3: ...oint control deviation transmitter supply 13 V 22 mA OUT5 OUT6 Optocoupler as OUT1 and OUT2 OPTION All logic signals can be OR linked RELAY OUTPUTS OUT1 OUT2 Contacts 2 NO contacts with common connect...

Страница 4: ...tched off Switch over to a safe output value Switch over to a mean output value PID controller SP setpoint power on disturbance t SP St process value Start up circuit When the process is controlled to...

Страница 5: ...ection if there is no response of the process to a change of output value Sensor break or short circuit Depending on selected input type the input signal is monitored for break and short circuit MAINT...

Страница 6: ...tion 20 65 C For storage 40 70 C Humidity 75 yearly average no condensation Shock and vibration Vibration test Fc DIN 68 2 6 Frequency 10 150 Hz Unit in operation 1g or 0 075 mm Unit not in operation...

Страница 7: ...inputs outputs Forcing allows to write the analog and digital inputs and outputs via Modbus interface Adjustment of limits for operating hours and switching cycles Switch over to 60 Hz mains frequenc...

Страница 8: ...to specification 9 no manual 0 manual german D manual english E manual french F Standard 0 UL certified U DIN 3440 certified D ORDERING INFORMATION Description Order no Current converter 50A AC 9404 4...

Отзывы: