000115682/151018/0 WallPro 

EN - 17

•  Loosen the 2 wing knobs and release the bag frame again 

(refer to Fig. 6.2).

•  Clean the inside of the filter unit with an industrial vacuum 

cleaner. 

•  Install a new filter cartridge, put the washer

33

 on the rod 

and tighten the star knob

34

•  Release the lid stays (B). 

•  Close the hopper and tighten the star knobs. Make sure to 

tighten them all the way to prevent leakage. 

•  Close the frame and tighten the wing knobs. 

•  Install the dustbin. 

•  Turn the rotary knob (refer to Fig. 4.15C) in vertical 

position to open the shut-off valve. 

•  Energize the unit. 

•  Push and hold the FILTER CLEANING button (ref. Fig. 5.1D) 

for 10 seconds to reset the red LED. 

•  Dispose of the used filter cartridge in accordance with 

federal, state or local regulations.

Fig. 6.3 

A

C

B

B

D

 Replacement of the filter cartridge

6.3 

Emptying the dustbin

Due to the shut-off valve, it is possible to empty the dustbin 

while the fan is running. Therefore, it is not necessary to 

de-energize the unit. 

Personal protective equipment (PPE)

Wear respiratory protection and protective 

gloves when you empty the dustbin.

WARNING

Do not empty the dustbin while a filter cleaning 

cycle takes place. Make sure that the blue LED 

(refer to Fig. 5.1D) on the control panel is off. 

To empty the dustbin, do the following. 

Fig. 6.4

•  Option: de-energize the unit.

•  Turn the rotary knob (A) in horizontal position to close the 

shut-off valve. 

•  Loosen the quick release clamp (B) and remove the dustbin 

(C).

•  Empty the dustbin. 

•  Install the dustbin and fasten the quick release clamp. 

33.  The washer is supplied with the new filter cartridge
34.  The star knob is attached to a rope to prevent loss

•  Turn the rotary knob (A) in vertical position to open the 

shut-off valve. 

•  If applicable: energize the unit. 

•  Dispose of the contents of the dustbin in accordance with 

federal, state or local regulations. 

Fig. 6.4 

A

B

C

Emptying the dustbin

6.4 

Arm adjustment

If the extraction arm, or a part of it, does not stay in the 

desired position, you must adjust the friction. Refer to the 

corresponding installation manual how to adjust the balance. 

TROUBLESHOOTING

If the unit does not function (correctly), consult the checklist 

below to see if you can remedy the error yourself. Should this 

not be possible, contact your supplier.

WARNING

Obey the safety regulations that are written in 

chapter 3 when you carry out the activities below. 

Symptom

Problem

Possible 

cause

Solution

The red LED 

(FILTER 

CLOGGED) is 

on 

Pressure drop 

over the filter 

cartridge is 

too high

The pressure 

setting is not 

correct

Set the correct 

threshold value; 

ref. par. 4.9.2

No compressed 

air available

Connect or repair 

the compressed air 

supply

Clogged filter 

cartridge

Replace the filter 

cartridge; ref. par. 

6.2

The red LED 

(FILTER 

CLOGGED) 

remains on, 

even after 

filter 

replacement

Wrong status 

indication

The FILTER 

CLEANING 

button to reset 

the red LED is 

not held long 

enough

Push and hold the 

FILTER CLEANIG 

button (ref. Fig. 

5.1D) for 10 

seconds 

The fan does 

not start

The unit does 

not function

No mains 

voltage

Connect the mains 

voltage

The mains cord 

is defective

Repair or replace 

the mains cord

Loose contacts

Repair the contacts

Motor defective Repair or replace 

the motor

START/STOP 

FAN button 

(green) is 

defective

Replace the green 

button

Содержание WALLPRO

Страница 1: ...www plymovent com EN Stationary filter unit EN Installation and user manual WALLPRO...

Страница 2: ...of this document This publication is to be used for the standard model of the product of the type given on the cover page Thus the manufacturer cannot be held responsible for any damage resulting fro...

Страница 3: ...e 3 1 Introduction 3 2 Product description 4 3 Safety instructions 5 4 Installation 6 5 Use 14 6 Maintenance 15 7 Troubleshooting 17 8 Spare parts 18 9 Electrical diagram 18 10 Disposal 18 CE declarat...

Страница 4: ...product name serial number You can find these data on the identification plate 1 INTRODUCTION 1 1 Identification of the product The identification plate contains among other things the following data...

Страница 5: ...A 160 2x KUA 200 n a n a 2 x 1000 m h 2 x 1450 m h WallPro Basic 1 inlet left or right 2 inlets left and right 1250 m h n a 2100 m h 2 x 1550 m h 1 For fan type FUA 3000 2 For fan type FUA 4700 Silenc...

Страница 6: ...ations User manual Everyone working on or with the product must be familiar with the contents of this manual and must strictly observe the instructions therein The management should instruct the perso...

Страница 7: ...icient approved fire extinguishers suitable for fire classes ABC Do not leave any tools or other objects in or on the unit The welding current return circuit between the workpiece and the welding mach...

Страница 8: ...m s 160 Arm diameter 160 mm 200 Arm diameter 200 mm 3 Arm length 3 m 4 Arm length 4 m DM Direct mount EM External mount 11 The UL certification applies to the control box 12 For connection with the co...

Страница 9: ...embly Make sure that the non return valve can fully open In case of a LL 5 5 24 Manual on off switch on the hood incl LED working light option Install the cable gland M16 nut M16 C If not Install the...

Страница 10: ...3 3 Fig 4 6 Mounting of the arm bracket In case of WallPro Double DM If applicable Do the same procedure for the other arm bracket In case of EM Recommended installation height of the arm bracket at...

Страница 11: ...s coupling Connect the air hoses22 in the connectors and B C 21 You do not need these four bolts anymore The other two bolts remain unused but must stay in the inlet flange 22 The different colours si...

Страница 12: ...emove the blind plug C from the nearest left or right 24 cable gland B just below the indicator panel Feed the cable through the cable gland B inside the unit Tighten the cable gland 24 In case of a W...

Страница 13: ...gurations with an imperial duct size 6 in or 8 in 28 160 mm 6 in or 200 mm 8 in depending on the inlet diameter 4 8 1 Dustbin extension set option For easy maintenance you can install the dustbin on t...

Страница 14: ...e Power Thermal relay Range Setting Single FUA 3000 230 V 2 HP 4 0 6 3 A 5 2 A 460 V 2 HP 2 2 3 2 A 2 4 A 575 V 2 HP 1 7 2 4 A 2 1 A PowerPlus FUA 4700 230 V 3 HP 7 5 10 5 A 8 8 A Double 460 V 3 HP 4...

Страница 15: ...paragraph 1 3 Fig 4 23 A B Fan outlet transition 4 11 Commissioning checklist Check Ref par OK 1 Are all cables correctly installed 4 9 1 2 Are the air hoses and correctly installed 4 9 1 3 Is the dir...

Страница 16: ...filter cartridge refer to paragraph 6 2 To prevent unnecessary filter replacement make sure that compressed air is available and connected the pressure setting is correct refer to paragraph 4 9 2 5 3...

Страница 17: ...replace the filter cartridge Personal protective equipment PPE Wear respiratory protection and protective gloves when you replace the filter cartridge WARNING Do not replace the filter cartridge whil...

Страница 18: ...The washer is supplied with the new filter cartridge 34 The star knob is attached to a rope to prevent loss Turn the rotary knob A in vertical position to open the shut off valve If applicable energi...

Страница 19: ...ue button Dust leakage from the hopper Sealing is insufficient The adhesive rubber strip is damaged or worn Replace the adhesive rubber strip The star knobs of the hopper are not fully tightended Full...

Страница 20: ...ibility that the product WallPro which this declaration refers to is in accordance with the conditions of the following Directives Machine Directive 2006 42 EC EMC 2014 30 EU LVD 2014 35 EU ErP Direct...

Страница 21: ...Dimens es FR Dimensions PL Wymiary A B C E D F G H WallPro mm inch A 700 27 6 B Single 1991 78 4 Basic Single PowerPlus 2059 81 1 Basic PowerPlus Double C 1236 48 7 D 975 38 4 E 764 30 1 F 123 4 8 G K...

Страница 22: ...orking range Max distance Max angle Mounting position E Wall mounting F On a stanchion or similar NL Werkbereik Max afstand Max hoek E Wandmontage F DE Bereich E F FR Port e E F ES Alcance de trabajo...

Страница 23: ...SET 5 SET 5 SET 5 SET 5 SET 1 Wall bracket 2x Bolt M10x30 2x Locknut M10 4x Washer M10 SET 2 Side panel 1x Screw plug M16 1x Nut M16 1x Cable gland M16 24x Bolt M6x16 24x Sealing washer M6 SET 3 Reinf...

Страница 24: ...d e d installation E configuration des trous ES Altura de instalaci n recomendada E dise o de agujeros IT Altezza di installazione raccommandata E disposizione dei fori PT PL Zalecana wysoko monta u E...

Страница 25: ...83 0040900010 0000117119 0000118185 0000117120 0000117546 0000117872 0000117875 0000117871 0000117900 0000118194 EN Exploded view filter unit WallPro NL Exploded view filterunit WallPro DE Explosionsz...

Страница 26: ...alve 160 mm NRV 160 Terugslagklep 160 mm NRV 160 R ckschlagklappe 160 mm WallPro FR Pi ces d tach es ES Piezas de recambio IT Pezzi di ricambio 0000100306 FUA 3000 IEC 400V 3ph 50Hz FUA 3000 IEC 400V...

Страница 27: ...Exploded view control box 0000102289 0000117869 0000117868 CE 0000118192 UL 0000101413 CE UL 0000102287 0000102288 0000117133 0000117134 0040900200 0000117870 0000117120 0000117873 0000117874 00001179...

Страница 28: ...mbar sticker schaal 60Hz Differenzdruckschalter 6 50 mbar Aufkleber Skala 60Hz 0040900200 Thermal relay NTR 4 0 6 3 A Thermisch relais NTR 4 0 6 3 A Thermisches Relai NTR 4 0 6 3 A Control box FR Pi c...

Страница 29: ...www plymovent com 000115682 151018 0 WallPro...

Отзывы: