000115682/151018/0 WallPro
EN - 17
• Loosen the 2 wing knobs and release the bag frame again
(refer to Fig. 6.2).
• Clean the inside of the filter unit with an industrial vacuum
cleaner.
• Install a new filter cartridge, put the washer
33
on the rod
and tighten the star knob
34
.
• Release the lid stays (B).
• Close the hopper and tighten the star knobs. Make sure to
tighten them all the way to prevent leakage.
• Close the frame and tighten the wing knobs.
• Install the dustbin.
• Turn the rotary knob (refer to Fig. 4.15C) in vertical
position to open the shut-off valve.
• Energize the unit.
• Push and hold the FILTER CLEANING button (ref. Fig. 5.1D)
for 10 seconds to reset the red LED.
• Dispose of the used filter cartridge in accordance with
federal, state or local regulations.
Fig. 6.3
A
C
B
B
D
Replacement of the filter cartridge
6.3
Emptying the dustbin
Due to the shut-off valve, it is possible to empty the dustbin
while the fan is running. Therefore, it is not necessary to
de-energize the unit.
Personal protective equipment (PPE)
Wear respiratory protection and protective
gloves when you empty the dustbin.
WARNING
Do not empty the dustbin while a filter cleaning
cycle takes place. Make sure that the blue LED
(refer to Fig. 5.1D) on the control panel is off.
To empty the dustbin, do the following.
• Option: de-energize the unit.
• Turn the rotary knob (A) in horizontal position to close the
shut-off valve.
• Loosen the quick release clamp (B) and remove the dustbin
(C).
• Empty the dustbin.
• Install the dustbin and fasten the quick release clamp.
33. The washer is supplied with the new filter cartridge
34. The star knob is attached to a rope to prevent loss
• Turn the rotary knob (A) in vertical position to open the
shut-off valve.
• If applicable: energize the unit.
• Dispose of the contents of the dustbin in accordance with
federal, state or local regulations.
Fig. 6.4
A
B
C
Emptying the dustbin
6.4
Arm adjustment
If the extraction arm, or a part of it, does not stay in the
desired position, you must adjust the friction. Refer to the
corresponding installation manual how to adjust the balance.
7
TROUBLESHOOTING
If the unit does not function (correctly), consult the checklist
below to see if you can remedy the error yourself. Should this
not be possible, contact your supplier.
WARNING
Obey the safety regulations that are written in
chapter 3 when you carry out the activities below.
Symptom
Problem
Possible
cause
Solution
The red LED
(FILTER
CLOGGED) is
on
Pressure drop
over the filter
cartridge is
too high
The pressure
setting is not
correct
Set the correct
threshold value;
ref. par. 4.9.2
No compressed
air available
Connect or repair
the compressed air
supply
Clogged filter
cartridge
Replace the filter
cartridge; ref. par.
The red LED
(FILTER
CLOGGED)
remains on,
even after
filter
replacement
Wrong status
indication
The FILTER
CLEANING
button to reset
the red LED is
not held long
enough
Push and hold the
FILTER CLEANIG
button (ref. Fig.
5.1D) for 10
seconds
The fan does
not start
The unit does
not function
No mains
voltage
Connect the mains
voltage
The mains cord
is defective
Repair or replace
the mains cord
Loose contacts
Repair the contacts
Motor defective Repair or replace
the motor
START/STOP
FAN button
(green) is
defective
Replace the green
button