![Plymovent SPARKSHIELD Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/plymovent/sparkshield/sparkshield_installation-and-user-manual_1569296008.webp)
0507061510/010921/C SparkShield
7
SparkShield-250 | 400 | 500 | 10 | 16 | 20:
• Support the spark arrester, preferably with straps.
• Demount the entire spark arrester by loosening the duct
clamps at both sides and bring it down.
• Disassemble the spark arrester.
• Clean the SparkTwist and the inlet + outlet of the housing
(inside).
• Assemble and install the spark arrester in reverse order.
SparkShield-630 | 24:
The spark arrester has a hatch for inspection and service
purposes on each side of the housing.
• Open the front hatch (A).
Fig. 5.1
A
Inspection and service hatch
• Remove the cotter pin from the axle.
Fig. 5.2 Cotter pin
• Move the SparkTwist (A) to the hatch.
•
Turn the SparkTwist (B) sectionwise and clean it.
Fig. 5.3
A
B
Move + clean
• Move the SparkTwist back to the inlet.
• Attach it with the cotter pin.
• Close the hatch and fasten the draw latches.
5.3
Replacement of the dustbin
ATTENTION
The dustbins are disposable. To guarantee a
dust-free procedure we recommend not to empty
the dustbin but to dispose it of and to install a new
one.
The dustbin cover is provided with a flexible hose to facilitate
replacement of the dustbin.
To replace the dustbin, do the following.
•
Turn off the connected extraction fan.
Without shut-off valve:
• Loosen the quick connect coupling (ref. Fig. 4.2C) and take
the dustbin away.
• Close the dustbin with the lid that is supplied with the new
dustbin.
• Install a new dustbin and connect it in reverse order.
• Turn on the extraction fan.
• Dispose of the used dustbin in accordance with state or
local regulations.
With shut-off valve:
•
Put the handle in horizontal position to close the shut-off
valve (ref. Fig. 2.3B).
• Loosen the quick connect coupling (ref. Fig. 4.2C) and take
the dustbin away.
• Close the dustbin with the lid that is supplied with the new
dustbin.
• Place a new dustbin and connect it in reverse order.
•
Put the handle in vertical position to open the shut-off
valve (ref. Fig. 2.3A).
• Dispose of the used dustbin in accordance with state or
local regulations.
WARNING
Make sure that the handle of the shut-off valve is in
vertical position (=open) during use.
6
SPARE PARTS
The following spare parts are available for the filter
unit;
- refer to exploded view Fig. VI on page 10
7
DISPOSAL
After life of the product, dispose of it in accordance
with federal, state or local regulations.