Plymovent SPARKSHIELD Скачать руководство пользователя страница 10

0507061510/010921/C SparkShield 

9

ANNEX

Fig. II 

Pressure drop

PRESSURE DROP & WORKING RANGE

SparkShield-

250

400

500

630

10

16

20

24

Pressure drop
Working range
(max. 800 Pa / 3 in. WG)

0

200

400

600

800

1000

1200

1400

0

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000

Volume d’air (m

3

/h)

Pert

e de charge 

(Pa

)

Pert

e de charge 

(pouces colo

nne d’eau

)

500 1000 1500 2000

1

2

3

4

5

2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000

Volume d’air (pc/min.)

0

200

400

600

800

1000

1200

1400

0

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000

Cantidad de aire (m

3

/h)

Caída de presió

(Pa

)

0

200

400

600

800

1000

1200

1400

0

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000

Luftflöde (m

3

/h)

Tryckfall 

(Pa

)

Caída de presió

(pulgadas columna de agua

)

500 1000 1500 2000

1

2

3

4

5

2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000

Cantidad de aire (pies cúbicos/min.)

0

200

400

600

800

1000

1200

1400

0

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000

Luchtstroom (m

3

/h)

Drukval 

(Pa

)

0

200

400

600

800

1000

1200

1400

0

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000

Luftvolumen (m

3

/h)

Druckverlust

 (

Pa

)

0

0

1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 13000 14000  

16000  

18000  

  20000 

 22000

Airflow (m³/h)

200

400

600

800

1000

1200

1400

P

ressure

 dr

o

p

 (

Pa

)

P

ressure

 dr

o

p

 (

in. WG

)

1

2

3

4

5

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000

9000

10000

11000

12000

13000

14000

24000

Airflow (CFM)

Airflow (m³/h)

24000

2000

0

4000

6000

8000

10000

12000

14000

20000

22000

16000

18000

26000

28000

30000

32000

34000

36000

38000

40000

200

400

600

800

1000

1200

1400

P

ressure

 dr

o

p

 (

Pa

)

1

2

3

4

5

0

500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500 8000

9000

10000

11000

12000

13000

14000

Airflow (CFM)

SparkShield-250 | 10

SparkShield-400 | 16

SparkShield-500 | 20

SparkShield-630 | 24

Fig. III 

Mounting instructions | airflow direction

Airflow direction

Fig. IV 

Mounting instructions | duct installation

Perpendicular without bend(s)

Содержание SPARKSHIELD

Страница 1: ...www plymovent com Cyclonic spark arrester SPARKSHIELD Installation and user manual EN...

Страница 2: ...e and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given on the cover page Thus the manufacturer...

Страница 3: ...the supplier of the product He will always be willing to help you Make sure you have the following specifications at hand product name serial number 1 INTRODUCTION 1 1 General description The SparkShi...

Страница 4: ...F G H A B C D E F G H Fig 2 1 Main components 2 2 Operation The SparkShield consists of a horizontally mounted in line spark arrester with dustbin underneath Due to their weight sparks and other debr...

Страница 5: ...d by the manufacturer inclusive of his directions in the sales brochure In case of doubt it is the use which can be deduced from the construction the model and the function of the technical product wh...

Страница 6: ...min 6 Duct imperial size inch Place a reducer metric imperial 10 16 20 24 in A in both duct ends and fasten them with self tapping screws min 6 Lift the spark arrester C in line with the duct and moun...

Страница 7: ...ied with the inspection hatches Insert the hatches in the cut outs Turn the handles 90 to fasten them and make the ducts airtight Refer to the mounting instruction supplied with the inspection hatches...

Страница 8: ...cover is provided with a flexible hose to facilitate replacement of the dustbin To replace the dustbin do the following Turn off the connected extraction fan Without shut off valve Loosen the quick co...

Страница 9: ...13 1 1 1 12 1 1 1 11 1 10 1 9 1 D B G B A C E F B G H D B A C E F SparkShield 250 10 400 16 500 20 630 24 mm inch mm inch mm inch mm inch A 500 19 710 28 900 35 1125 44 B 250 9 400 15 500 19 630 24 C...

Страница 10: ...000 10000 11000 12000 13000 14000 16000 18000 20000 22000 Airflow m h 200 400 600 800 1000 1200 1400 Pressure drop Pa Pressure drop in WG 1 2 3 4 5 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 550...

Страница 11: ...10 5 0000103074 SparkTwist 0000103081 0000103082 0000103083 0000103084 0690020040 0690020050 Article no Description 9824000300 DB 13 Dustbin 13 litres 9824000310 DB 13 Dustbin 13 litres 5 pcs 98240004...

Страница 12: ...www plymovent com 0507061510 010921 C SparkShield...

Отзывы: