PREFACE

Using this manual

This manual is intended to be used as a work of reference for 

professional, well trained and authorised users to be able to 

safely install, use, maintain and repair the product mentioned 

on the cover of this document. 

Pictograms and symbols

The following pictograms and symbols are used in this manual:

TIP

Suggestions and recommendations to simplify 

carrying out tasks and actions.

ATTENTION

A remark with additional information for the user. A 

remark brings possible problems to the user’s 

attention.

CAUTION!

Procedures, if not carried out with the necessary 

caution, could damage the product, the workshop or 

the environment. 

WARNING!

Procedures which, if not carried out with the 

necessary caution, may damage the product or 

cause serious personal injury. 

CAUTION!

Risk of electric shok. 

WARNING!

Fire hazard! Important warning to prevent fire. 

WARNING!

Explosion hazard! Important warning to prevent 

explosions. 

Personal protective equipment (PPE)

Instruction to use respiratory protection when you 

do service, maintenance and repair jobs, as well as 

during functional testing. We recommend to use a 

half-face respirator according to EN 149:2001 + 

A1:2009, classe FFP3 (Directive 89/686/EEC).

Personal protective equipment (PPE)

Instruction to use protective gloves when you do 

service, maintenance and repair jobs.

Text indicators

Listings indicated by “-” (hyphen) concern enumerations. 

Listings indicated by “•” (bullet point) describe steps to 

perform. 

Service and technical support

For information about specific adjustments, maintenance or 

repair jobs which are not dealt with in this manual, please 

contact the supplier of the product. He will always be willing to 

help you. Make sure you have the following specifications at 

hand:

 

- product name

 

- serial number

You can find these data on the identification plate.

Product indications

 

- MultiDust Bank equals to: MDB

 

- The specific product type (4/6/8 etc.) corresponds with the 

number of filter cartridges 

 

- Suffixes: 

 

- H: horizontal layout

 

- V: vertical layout

 

- no suffix: square layout

INTRODUCTION

1.1 

Identification of the product

The identification plate contains, among other 

things, the following data:

 

- product name

 

- serial number

 

- supply voltage and frequency

 

- power consumption

1.2 

General description

The MDB is a central filter system that consists of modular 

components. The position of the air inlet and air outlet 

modules is variable. Dust collection in a dustbin underneath 

each stack of filter modules.

Filter cartridges, extraction fan and control equipment are not 

included and must be selected and ordered separately. 

1.3 

Product combinations

1.3.1  Filter cartridges

To operate the system, selection of filter cartridges is required. 

The following types are available:

Filter:
type

surface

material

CART-D:

Premium Plus

15 m²

BiCo spunbond polyester

Premium

15 m²

spunbond polyester

Economy

15 m²

cellulose

CART-C

15 m²

BiCo spunbond polyester, 

antistatic

CART-E

15 m²

BiCo spunbond pol PTFE 

impregnation

CART-PTFE

10 m²

BiCo spunbond pol PTFE 

membrane

15 m²

CART-MB

10,7 m²

cellulose with polypropylene 

microfiber overlay, 

electrostatically charged

The specific product type (MDB-4, MDB-12, etc.) corresponds 

with the required number of filter cartridges. 

Precoat

To enhance the efficiency and lifespan of the filter cartridges, it 

is strongly recommended to add precoat material (PRECO-N). 

This applies to all types of filter cartridges, except for CART-

PTFE and CART-MB. 

Dosing per filter cartridge: 500 g (1.1 lbs.).

1.3.2  Extraction fan

The required capacity of the extraction fan depends on the size 

of the MDB system, the required filter performance and the 

permitted air flow through the filter cartridges.

Table I on page 16 gives an overview of the minimum and 

maximum airflow per MDB type, as well as the minimum and 

maximum motor power of the fan. 

1.3.3  Control equipment

There are two ways to control the filter cleaning system of the 

MDB and the connected fan. 

Содержание MDB GO

Страница 1: ...www plymovent com Central filter system modular MDB GO MDB PRO Installation and user manual EN...

Страница 2: ...uideline for installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given...

Страница 3: ...iDust Bank equals to MDB The specific product type 4 6 8 etc corresponds with the number of filter cartridges Suffixes H horizontal layout V vertical layout no suffix square layout 1 INTRODUCTION 1 1...

Страница 4: ...to ISO 8573 3 class 6 Required pressure 4 5 bar 60 75 PSI Compressed air connection push in fitting in in out 12 mm Compressed air consumption 40 50 nl pulse 1 4 1 8 ft pulse Electrical data Input vol...

Страница 5: ...uctions and directions given Do not change the order of the steps to perform Always keep the manual with the product Pictograms and instructions on the product if present The pictograms warning and in...

Страница 6: ...s for persons who enter the work area Check the working environment Do not allow unauthorised persons to enter the working environment Protect the product against water and humidity Make sure the room...

Страница 7: ...V on page 18 B Air outlet module MDB OUTLET Fig 4 4 Drill a 9 mm 0 25 in hole in the two notches A of the outlet module Fig 4 2 A 2x Air outlet module 2 Note the open sides of the bars are on the outs...

Страница 8: ...g the sticky side with your fingers Make sure that you attach the seal in the centre of the frame edges and that the jigsaws fit together Peel approx 50 mm of the backing material A and stick the seal...

Страница 9: ...rry about a slight misalignment of the seal holes Fig 4 14 Start with a long seal 1046 mm Try to avoid touching the sticky side with your fingers Make sure that you attach the seal in the centre of th...

Страница 10: ...e Fig 4 16 Put the MDB FRAME A in fully horizontal position 8 The seals are extremely adhesive without the use of SealApplicator components might stick together in the wrong position and cannot be dis...

Страница 11: ...lter modules and tighten them with a flange nut B Fig 4 22 A A A A B B B B B A 4x B 5x Position of studs Fig 4 23 Multiple stack MDB system only 1 Remove the backing material of the seals horizontal v...

Страница 12: ...an end cap When you install ducting at both sides of the modules you do not need to install an end cap If applicable Put an end cap on the open side of the air inlet outlet module Fasten it with self...

Страница 13: ...hopper with the quick connect clamp B Fig 4 29 A B C D Dustbin 4 10 Electric connection For the electric connection of the filter cleaning system and the fan refer to the installation manual of the c...

Страница 14: ...s in the dustbin regularly The emptying frequency depends on the intensity of use and will be a matter of experience In the initial stage do a check on the level of contents of the dust drawer two tim...

Страница 15: ...cartridges Inverted direction of rotation of the motor of the connected fan Change the direction of rotation Pollution of the facility Filter cartridge s ripped or placed incorrectly Replace the filt...

Страница 16: ...s of the following Directives Machine Directive 2006 42 EC EMC 2014 30 EU LVD 2014 35 EU ErP Directive 2009 125 EC Alkmaar Netherlands 1 July 2019 M S J Ligthart Product Manager An installation is def...

Страница 17: ...51 5 5 15 7 5 20 PTFE 15 180 1938 5400 14400 3178 8476 MDB 16 16 PTFE 10 160 1722 4800 12800 2825 7534 5 5 18 5 7 5 25 PTFE 15 240 2583 7200 19200 4238 11301 MDB 18 18 PTFE 10 180 1938 5400 14400 3178...

Страница 18: ...4x 18x 2x 22x 26x 22x 11x MDB COVER 2 4x 18x 2x 22x 26x 22x 11x MDB COVER U 4x 18x 2x 22x 26x 22x 11x MDB INLET 315 MDB INLET 400 MDB INLET 500 4x 18x 2x 22x 26x 22x 11x MDB OUTLET 315 MDB OUTLET 400...

Страница 19: ...uence of MDB system if applicable install the MDB BM 2 module s first layer by layer from left to right one filter module at a time 1 2 3 1 2 3 4 5 6 1 2 3 2 4 6 Fig V Inlet and outlet positions Possi...

Страница 20: ...lve inch 0000102584 Lock kit for CART filter cartridge 0000102598 Star knob M12 0000102666 Cover plate for filter cartridge CART 0000102675 Filter cartridge holder Article no Description 0000103150 Ma...

Страница 21: ...www plymovent com 0000100513 050719 C MDB GO MDB PRO...

Отзывы: