0000100513/050719/C MDB GO | MDB PRO 

19

ANNEX

Fig. VI 

Exploded view

0000100297

0000100353

0000100354

0000100356

0000104642

0000102675

0000111381

0000111621

0000103150

0000102584

0000102598

0000111622 (option)

0000102666

0000102411

0000110523

0000110329

Article no.

Description

0000100297

CART-PTFE/10 / Filter cartridge

*)

0000100353

CART-C / Filter cartridge

*)

0000100354

CART-E / Filter cartridge

*)

0000100356

CART-D Premium Plus / Filter cartridge

*)

0000102315

CART-MB / Filter cartridge

*)

0000102411

Drain valve ½ inch

0000102584

Lock kit for CART filter cartridge

0000102598

Star knob M12

0000102666

Cover plate for filter cartridge CART 

0000102675

Filter cartridge holder

Article no.

Description

0000103150

Magnetic valve MDB, incl. 24V DC coil and 3 m cable

0000104642

CART-PTFE/15 / Filter cartridge

*)

0000110003

CART-D Premium / Filter cartridge

*)

0000110004

CART-D Economy / Filter cartridge

*)

0000110329

SealApplicator 1000 ml

0000110523

Spare seal set MDB

0000111621

Lid for connection of DB-80 to HOPPER

0000111381

DB-80 / Dustbin 80 litres, incl. lifting pin and handles

*)

 

Filter cartridge, incl. facemask, disposable gloves and plastic sack with seal for 

collection and disposal of the used filter cartridge

Содержание MDB GO

Страница 1: ...www plymovent com Central filter system modular MDB GO MDB PRO Installation and user manual EN...

Страница 2: ...uideline for installation use maintenance and repair of the product mentioned on the cover page of this document This publication is to be used for the standard model of the product of the type given...

Страница 3: ...iDust Bank equals to MDB The specific product type 4 6 8 etc corresponds with the number of filter cartridges Suffixes H horizontal layout V vertical layout no suffix square layout 1 INTRODUCTION 1 1...

Страница 4: ...to ISO 8573 3 class 6 Required pressure 4 5 bar 60 75 PSI Compressed air connection push in fitting in in out 12 mm Compressed air consumption 40 50 nl pulse 1 4 1 8 ft pulse Electrical data Input vol...

Страница 5: ...uctions and directions given Do not change the order of the steps to perform Always keep the manual with the product Pictograms and instructions on the product if present The pictograms warning and in...

Страница 6: ...s for persons who enter the work area Check the working environment Do not allow unauthorised persons to enter the working environment Protect the product against water and humidity Make sure the room...

Страница 7: ...V on page 18 B Air outlet module MDB OUTLET Fig 4 4 Drill a 9 mm 0 25 in hole in the two notches A of the outlet module Fig 4 2 A 2x Air outlet module 2 Note the open sides of the bars are on the outs...

Страница 8: ...g the sticky side with your fingers Make sure that you attach the seal in the centre of the frame edges and that the jigsaws fit together Peel approx 50 mm of the backing material A and stick the seal...

Страница 9: ...rry about a slight misalignment of the seal holes Fig 4 14 Start with a long seal 1046 mm Try to avoid touching the sticky side with your fingers Make sure that you attach the seal in the centre of th...

Страница 10: ...e Fig 4 16 Put the MDB FRAME A in fully horizontal position 8 The seals are extremely adhesive without the use of SealApplicator components might stick together in the wrong position and cannot be dis...

Страница 11: ...lter modules and tighten them with a flange nut B Fig 4 22 A A A A B B B B B A 4x B 5x Position of studs Fig 4 23 Multiple stack MDB system only 1 Remove the backing material of the seals horizontal v...

Страница 12: ...an end cap When you install ducting at both sides of the modules you do not need to install an end cap If applicable Put an end cap on the open side of the air inlet outlet module Fasten it with self...

Страница 13: ...hopper with the quick connect clamp B Fig 4 29 A B C D Dustbin 4 10 Electric connection For the electric connection of the filter cleaning system and the fan refer to the installation manual of the c...

Страница 14: ...s in the dustbin regularly The emptying frequency depends on the intensity of use and will be a matter of experience In the initial stage do a check on the level of contents of the dust drawer two tim...

Страница 15: ...cartridges Inverted direction of rotation of the motor of the connected fan Change the direction of rotation Pollution of the facility Filter cartridge s ripped or placed incorrectly Replace the filt...

Страница 16: ...s of the following Directives Machine Directive 2006 42 EC EMC 2014 30 EU LVD 2014 35 EU ErP Directive 2009 125 EC Alkmaar Netherlands 1 July 2019 M S J Ligthart Product Manager An installation is def...

Страница 17: ...51 5 5 15 7 5 20 PTFE 15 180 1938 5400 14400 3178 8476 MDB 16 16 PTFE 10 160 1722 4800 12800 2825 7534 5 5 18 5 7 5 25 PTFE 15 240 2583 7200 19200 4238 11301 MDB 18 18 PTFE 10 180 1938 5400 14400 3178...

Страница 18: ...4x 18x 2x 22x 26x 22x 11x MDB COVER 2 4x 18x 2x 22x 26x 22x 11x MDB COVER U 4x 18x 2x 22x 26x 22x 11x MDB INLET 315 MDB INLET 400 MDB INLET 500 4x 18x 2x 22x 26x 22x 11x MDB OUTLET 315 MDB OUTLET 400...

Страница 19: ...uence of MDB system if applicable install the MDB BM 2 module s first layer by layer from left to right one filter module at a time 1 2 3 1 2 3 4 5 6 1 2 3 2 4 6 Fig V Inlet and outlet positions Possi...

Страница 20: ...lve inch 0000102584 Lock kit for CART filter cartridge 0000102598 Star knob M12 0000102666 Cover plate for filter cartridge CART 0000102675 Filter cartridge holder Article no Description 0000103150 Ma...

Страница 21: ...www plymovent com 0000100513 050719 C MDB GO MDB PRO...

Отзывы: