background image

LM/USA/CAN/5/13

Spiral Cable

Extendable up to 3 m. To be used when installing
switch assembly for PlymoVent LM-2 and
Extractor Cranes ”Plymoth

®

”.

Prod. no: SK-300

Complementary Products and Accessories

Fan
Prod
no.

Airflow

CFM

Freeblowing

Motor
HP/Phase

Airflow CFM
at the hood of
the LM-2

825
825

1060
1300

1300

2000

2840

3540

FUA-1300
FUA-1301
FUA-1800
FUA-2100

FUA-2101

FS-3000

FS-4700

FA-6000

1/2 HP, 3 phase
1/2 HP, 1 phase
3/4 HP, 3 phase
1 HP, 3 phase

1 HP, 1 phase

1.5 HP, 3 phase

3 HP, 3 phase

7.5 HP, 3 phase

1 LM = 590
1 LM = 590
1 LM = 740
1 LM = 825
2 LM = 380 ea

1 LM = 825
2 LM = 380 ea

2 LM = 765 ea
3 LM = 500 ea

3 LM = 765 ea
4 LM = 560 ea

4 LM = 765 ea
5 LM = 620 ea

F S

F U A

NOTE: ALL FANS MUST BE FITTED WITH RELEVANT
MOTOR OVERLOAD (NOT INCLUDED).

Stanchion

Accessory for ceiling, floor
or wall mounting of LM-2.
Length: 3.6 ft. 

Prod No: PA-110.

Length: 7.2 ft. 

Prod No: PA-220.

Halogen Lamp Cartridge

To be fitted in the hood. Consists of 20W/24V
halogen lamp, switch assembly and 32.8 ft cable.
Must be complemented with
transformer TR-24 or starter SA-24.

Prod No. SK-20/24

Transformer

115 VAC-24V/sec. Transformer for
halogen lamp cartridge HL-20/24.

Prod No. TR-24

Control Unit

For automatic start or stop of a central fan up
to 5 HP in a system with several extractors.
To be used in conjunction with the Energy
Saver or Automatic Damper. Line supply:
115 thru 460 VAC.

Prod No. M-1000

Starter

For manual start/stop of the fan up to 5 HP via a
switch in the hood. Complete with switch assembly
and 32.8 ft cable. Built-in contactor must be fitted
with relevant fan-motor overload (not included).
Line supply: 115 thru 460 VAC.

Prod No. SA-24/75

 includes 75 VA/24V

transformer for halogen lamp on one workstation.

Semi-rigid Extension Hose

For all extraction arms 6.30" in diameter. Connects
with quick-fit coupling. Flexible and adjustable,
4.92 diameter. Length 3.3 ft.

Prod No. FSL-1

Extension Hose

Ø 6.30" extension hose with quick-fit coupling for
connection to the fume extraction arm. PVC
coated woven glassfibre with inner steel spiral
support.
Hood with double magnetic foot and handle
for easy positioning.

Prod No. SLE-20

, 6.6 ft in length

Prod No. SLE-30

, 9.8 ft in length

Electrostatic Filters

Clean the air so efficiently (up to 99.9%) that
you may recirculate the already heated air into
the workshop. Huge energy savings. Also
excellent for filtering oilmist. Are available
in sizes up to 2950 CFM.

For more information, see technical data
for oilmist and Electrostatic Filters (EF/EFO).

Fans FUA

FUA fans are attached directly to the LM-2 mounting
bracket. Available in three sizes with freeblowing air
volumes of 825, 1060 and 1300 CFM. A unique
anti-spark impeller made from aluminium gives
maximum security. For wall- or ceiling mounted,
choose "FS"-fan stand models 1300, 1800 or
2100. In a system with more than one
extractor, we recommend the wall
mounted FS-3000, 4700 or FA-6000.

Automatic Damper

Fully automatic motor driven damper for fitting
to Ø 6.30" duct. Adjustable overrun period
between 7 seconds and 6 minutes, to cap-
ture after-fume. Inductive sensor clamp
with 16.4 ft of cable is included as stan-
dard. Line supply: 115 thru 460 VAC.
Also includes switch assembly (S-100)
for manual control from the hood.

Prod No. ASE-12

Energy Saver

For autom. start/stop of fan. Adjustable overrun
period of between 7 sec. - 6 min. Incl. inductive
sensor clamp with 16.4 ft of cable. Built-in contac-
tor for up to 5 HP fan must be fitted with relevant
fan-motor overload (not included).
Line supply: 115 thru 460 VAC.

Prod No. ES-90-005

 Incl. 75 VA/24V

transformer. For one arm with light and one fan.

* Other voltages are available

* Other voltages are available

* Other voltages are available

* Other voltages are available

* Other voltages are available

* Other voltages are available

Содержание Junior LM-2

Страница 1: ...Product manual Junior LM 2 THIS MANUAL SHOULD BE HANDED OVER AND KEPT BY THE SERVICE DEPARTMENT AFTER THE INSTALLATION Thank you for buying a PlymoVent product Before you unpack and put it into operat...

Страница 2: ...g assisted vertical movement Flexible working radius due to the telescopic operation Small and compact Ideal for confined working areas and low ceiling heights The one and only benchwork extractor Wid...

Страница 3: ...tanchion PA 110 or PA 220 Ceiling mounted LM 2 with stanchion PA 110 or PA 220 and separate fan Floor mounted LM 2 with stanchion PA 220 and separate fan The following aspects affect the pressure loss...

Страница 4: ...it and one central fan Recommended fan per no of arms FS 2100 2 4 arms FS 3000 3 6 arms FS 4700 4 8 arms FA 6000 4 8 arms As every working place is unique the above recommendations are only applicable...

Страница 5: ...ith quick fit coupling Flexible and adjustable 4 92 diameter Length 3 3 ft Prod No FSL 1 Extension Hose 6 30 extension hose with quick fit coupling for connection to the fume extraction arm PVC coated...

Страница 6: ...USA CAN 6 13 BSAB no T0 31 Ser no LM MA Date Sept 97 Replace Jan 95 MOUNTING INSTRUCTION JUNIOR LM 2 Pos no DESCRIPTION A Wall mounting bracket B Counterweight C LM 2 D Hood collar E Hood F Spigot G F...

Страница 7: ...SA CAN 7 13 10 mm 17 mm 6 mm Mounting instructions 1 Bolt mounting bracket to wall 2 Attach arm to mounting bracket 3 Mount counter weight 1 and tube over counter weight 2 4 Adjust to the desired fric...

Страница 8: ...LM USA CAN 8 13 5 Pull over the rubber seal 6 Fix flexible hose in place using jubilee clips as supplied...

Страница 9: ...LM USA CAN 9 13 For individual fan For central system 7 Mount spigot 160 mm 6 3...

Страница 10: ...justments must be made to the friction collar This is done by either loosening or tightening the screw Use an allen key B If the hood will not stay in the required position 1 Loosen the hose at B 2 Ad...

Страница 11: ...ther until the old wire comes through at the lower end 5 Put the upper end of the new wire through the eye of the old wire Pull at the upper end of the old wire until the new wire at the top of the tu...

Страница 12: ...LM USA CAN 12 13 BSAB no T0 31 Ser no LM RR Date Sept 97 Replace Jan 95 SPARE PART DRAWING JUNIOR LM 2...

Страница 13: ...RD GUIDE AXLE CEN PART 6 961 920 1 LOCK WASHER 7 509653 LEGO 1 LM 2 WALL MOUNTING BRKT PART 8 964 213 1 COUNTERWEIGHT CORD LM 2 9 972 398 1 RUBBER COLLAR KUA LM 2 10 951 939 1 WASHER 21x36x3 FZB 11 50...