background image

LM/USA/CAN/11/13

To change wire

1.

Unbolt the counterweight tube.

2.

Loosen both jubilee clips and push the hose together in the middle of the telescopic tube.

3.

Detach the counterweight.

4.

Unscrew the bolt holding the hood attachment to the telescopic tube, and remove the
hood attachment carefully. Push the telescopic section together until the old wire comes
through at the lower end.

5.

Put the upper end of the new wire through the eye of the old wire. Pull at the upper end
of the old wire until the new wire at the top of the tube. Pull the new wire at the top until
the eye at the lower end is in line with the hole for the bolt. Push the hood attachment
onto the telescopic tube very carefully and fasten the bolt.

6.

Tie the new wire to the counterweight as before.

7.

Mount the new wire as shown on picture.

8.

Re-position the counterweight tube and the hose.

Содержание Junior LM-2

Страница 1: ...Product manual Junior LM 2 THIS MANUAL SHOULD BE HANDED OVER AND KEPT BY THE SERVICE DEPARTMENT AFTER THE INSTALLATION Thank you for buying a PlymoVent product Before you unpack and put it into operat...

Страница 2: ...g assisted vertical movement Flexible working radius due to the telescopic operation Small and compact Ideal for confined working areas and low ceiling heights The one and only benchwork extractor Wid...

Страница 3: ...tanchion PA 110 or PA 220 Ceiling mounted LM 2 with stanchion PA 110 or PA 220 and separate fan Floor mounted LM 2 with stanchion PA 220 and separate fan The following aspects affect the pressure loss...

Страница 4: ...it and one central fan Recommended fan per no of arms FS 2100 2 4 arms FS 3000 3 6 arms FS 4700 4 8 arms FA 6000 4 8 arms As every working place is unique the above recommendations are only applicable...

Страница 5: ...ith quick fit coupling Flexible and adjustable 4 92 diameter Length 3 3 ft Prod No FSL 1 Extension Hose 6 30 extension hose with quick fit coupling for connection to the fume extraction arm PVC coated...

Страница 6: ...USA CAN 6 13 BSAB no T0 31 Ser no LM MA Date Sept 97 Replace Jan 95 MOUNTING INSTRUCTION JUNIOR LM 2 Pos no DESCRIPTION A Wall mounting bracket B Counterweight C LM 2 D Hood collar E Hood F Spigot G F...

Страница 7: ...SA CAN 7 13 10 mm 17 mm 6 mm Mounting instructions 1 Bolt mounting bracket to wall 2 Attach arm to mounting bracket 3 Mount counter weight 1 and tube over counter weight 2 4 Adjust to the desired fric...

Страница 8: ...LM USA CAN 8 13 5 Pull over the rubber seal 6 Fix flexible hose in place using jubilee clips as supplied...

Страница 9: ...LM USA CAN 9 13 For individual fan For central system 7 Mount spigot 160 mm 6 3...

Страница 10: ...justments must be made to the friction collar This is done by either loosening or tightening the screw Use an allen key B If the hood will not stay in the required position 1 Loosen the hose at B 2 Ad...

Страница 11: ...ther until the old wire comes through at the lower end 5 Put the upper end of the new wire through the eye of the old wire Pull at the upper end of the old wire until the new wire at the top of the tu...

Страница 12: ...LM USA CAN 12 13 BSAB no T0 31 Ser no LM RR Date Sept 97 Replace Jan 95 SPARE PART DRAWING JUNIOR LM 2...

Страница 13: ...RD GUIDE AXLE CEN PART 6 961 920 1 LOCK WASHER 7 509653 LEGO 1 LM 2 WALL MOUNTING BRKT PART 8 964 213 1 COUNTERWEIGHT CORD LM 2 9 972 398 1 RUBBER COLLAR KUA LM 2 10 951 939 1 WASHER 21x36x3 FZB 11 50...

Отзывы: