0000112607/010420/A ControlGo
5
4.3
Mounting
ATTENTION
Do not expose any component of ControlGo to
vibrations or heat radiation.
You must install the Panel at a clearly visible and accessible
position.
4.3.1 ControlGo/Panel
To install the Panel, do the following.
• Attach the mounting brackets (A) to the Panel with the
supplied mounting material (B).
• Install the Panel to the wall. Make sure that it is level.
ATTENTION
Before you install the Panel, make sure that the wall
is strong enough. Refer to paragraph 1.5.1 for the
weight.
Fig. 4.2
B (4x)
A (4x)
Mounting of the Panel
North America only:
• To comply with UL standard 508A, put the corresponding
sticker on the Panel.
Fig. 4.3
WARNING
Maintenance on Industrial Control
Panels shall only be performed by
trained, qualified, skilled and
authorized electricians, using
appropriate safe electrical work
practices including personal protective
equipment, approved tools, procedures
and accurate drawings of the panels
involved.
CAUTION
Risk of Electric shock
Disconnect Switch may be required to
de-energize before servicing.
AVERTISSEMENT
L'entretien des armoires industrielles
de contrôle doit être effectué
uniquement par des personnes
qualifiées, expertes et autorisés en ce
sens utilisant des méthodes de travail
appropriées et sécurisées, y compris
les équipements de protection
individuelle, les outils, les procédures
approuvées et schémas électrique des
armoires en question.
ATTENTION
Risque de tension électrique
Il pourrait être nécessaire d’installer
un interrupteur principal pour mettre
hors-tension la machine avant
d’entreprendre les travaux d’entretien.
UL compliance sticker
The bottom plate contains the following cable glands and
connectors:
A metal cable gland M20 for the mains cord
B universal cable glands M16 (6)
C bulkhead connectors
(2) for the pressure tubes
13
13. Filter pr and –
Fig. 4.4
A
B
C
Bottom plate
on page 19 gives an overview of the necessary and
optional cables that you need to install the system.
• Depending on the selected options and control equipment,
determine the number and type of cables that you need.
If the number exceeds 6 cables (excluding the mains cord),
you must install additional cable glands. In that case, do the
following.
• Loosen the pneumatic hoses (B) from the bulkhead
connectors from the inside of the Panel.
• Loosen and remove the bottom plate (C+D).
• Open the necessary number of knock-out holes
14
(A).
• Put additional cable glands M16 (E) in the bottom plate and
tighten them.
• Install the bottom plate.
• Fasten the pneumatic hoses to the bulkhead connectors.
WARNING
You must remove the bottom plate to put additional
cable glands to avoid damage to the interior parts of
the Panel.
C
B (2x)
C (6x)
D
E
A
B
C
B (2x)
C (6x)
D
E
A
B
C
B (2x)
C (6x)
D
E
A
B
Fig. 4.5 Additional cable glands (optional)
4.4
Electric connection
This chapter describes the electric connection of all
necessary and optional components to the Panel.
14. Max. 12