0000112607/010420/A ControlGo
13
In case of
one
(1) SCS system: proceed with
In the Learning Mode you “teach” the Panel about the size of
the filter system;
-
MDB: the number of filter cartridges (min. 2, max. 64)
-
SCS: the number of filter systems (1 or 2; default setting: 1)
At the same time, the Learning Mode verifies the cable
connections of the SlaveBoard(s) and the correct setting of the
DIP switches.
WARNING
You must go through the Learning Mode procedure
to make sure that all SlaveBoards of the filter
modules are correctly connected. If you fail to do
so, it can finally lead to a malfunction of the filter
cleaning system.
5.3.1 General
•
Follow the flowchart GENERAL on page 20.
In case of an MDB system:
• Proceed with paragraph 5.3.2
In case of two SCS systems:
• Proceed with paragraph 5.3.3
5.3.2 MDB
•
Follow the flowchart MDB on page 21.
5.3.3
SCS (two filter systems)
•
Follow the flowchart SCS (#2) on page 22.
6
USE
6.1
Control panel
The control panel contains the following controls and
indicators:
Fig. 6.1 (also refer to Fig. V on page 18)
A White LED | POWER ON
- LED
off: system is off
- LED blinking: system is starting up
- LED on: system is ready
B Green LED | FAN RUNNING
-
LED off: fan is off
- LED blinking: fan is ramping down
30
- LED on: fan is running
C Yellow LED | WARNING
-
LED off: no problem
- LED on
31
: the blinking pattern shows the cause of the
warning; refer to paragraph 6.3.1
D Red LED | ALARM
-
LED off: no problem
- LED on
32
: the blinking pattern shows the cause of the
alarm; refer to paragraph 6.3.2
E Main switch
F Green button | START/STOP FAN
- to start and stop the fan manually
- to reset the precoat timer (push and hold for 20 seconds)
30. Ramp down time: 60 seconds
31. The system continues to run
32. The system stops running
G Black button | FILTER CLEANING
-
to activate an additional filter cleaning cycle
- to suppress the buzzer (push and hold for 5 seconds)
33
- to reset the warning and alarm LED (push and hold for 5
seconds)
H Buzzer | acoustic signal
- together with the ALARM signal (D)
- in some cases: together with the WARNING signal (C)
I Tumbler switch 0-1 | Normal Mode / Service Mode
- normal use: Panel in Normal Mode (1)
- during service/maintenance/repair activities: put the
Panel in Service Mode (0)
34
Fig. 6.1
0 = Service Mode
1 = Normal Mode
A
B
C
D
E
F
I
G
H
Control panel
6.2
Use
6.2.1 Start/stop fan
You can start and stop the fan in two ways:
- manually by the START/STOP FAN button (ref. Fig. 6.1F)
- automatically
35
by an external signal from e.g. a welding
robot or a timer
6.2.2 Filter cleaning
The filter cleaning system can be activated in two ways:
- automatically, pressure controlled (refer to paragraph 2.2.1)
- manually by the FILTER CLEANING button (ref. Fig. 6.1G)
36
37
6.2.3 Service Mode
When you put the Panel in the Service Mode (ref. Fig. 6.1I),
the fan stops running immediately. In case the filter cleaning
system is active, it stops as well.
In the Service Mode, you can only start
38
/stop the fan and the
filter cleaning system manually. The automatic functions are
disabled.
33. You must still solve the cause of the alert
34.
In Service Mode you can only activate the fan and the filter system manually
35. Stop delay: 3 minutes for removal of after fumes, if any
36.
You cannot stop/interrupt the filter cleaning cycle
37.
You cannot activate this button during the first 40 running hours of the system
and within 40 running hours after filter replacement, to maintain the protective
layer of precoat material on the filter cartridges
38.
The filter cleaning system continues to run. Push the black button again or put
the Panel in Normal Mode to stop it.