background image

OPERATION & SPECIFICATIONS

·

The

 ECLISSE INDOOR 

is

 

an

 

LED

 

profile

 

light

 

for

 

on-site

 

decoration

 

purpose.

·

Don't turn on the fixture if it's been through severe temperature difference like after transportation

because it might damage the light due to the environment changes. So make sure to operate the

fixture until it is in normal temperature.

·

This light should be keep away from strong shaking during any transportation or movement.

·

Don't pull up the light by only the head, or it might cause damages to the mechanical parts.

·

Don't expose the fixture in overheat, moisture or environment with too much dust when installing

it. And don't lay any power cables on the floor. Or it might cause electronic shock to the people.

·

Make sure the installation place is in good safety condition before installing the fixture.

·

Make sure to put the safety chain and check whether the screws are screwed properly when

installing the fixture.

·

Make sure the lens are in good condition. It's recommended to replace the units if there are any

damages or severe scratch.

·

Make sure the fixture is operated by qualified personnel who knows the fixture before using.

·

Keep the original packages if any second shipment is needed.

·

Don't try to change the fixtures without any instruction by the manufacturer or the appointed

repairing agencies.

·

It is not in warranty range if there are any malfunctions from not following the user manual to

operate or any illegal operation, like shock short circuit, electronic shock, lamp broke, etc.

INSTALLATIONS

For added protection mount the fixtures in areas outside walking paths, seating areas, or in areas

were the fixture might be reached by unauthorized personnel.

Before mounting the fixture to any surface, make sure that the installation area can hold a

minimum point load of 10 times the device's weight.

Fixture installation must always be secured with a secondary safety attachment, such as an

appropriate safety cable.

Never stand directly below the device when mounting, removing, or servicing the fixture.

From a ceiling, or set on a flat level surface (see illustration below). Be sure this fixture is kept at

least 0.5m (1.5 ft) away from any flammable materials (decoration etc.).

10

11

ECLISSE

 

IN

DOOR

-PL

2

00

-

I

Содержание ECLISSE INDOOR PL200-I

Страница 1: ... ECLISSE Indoor User Instructions PROFILE PL200 I ...

Страница 2: ...ke sure the power cord is never crimped or damaged by sharp edges If this would be the case replacement of the cable must be done by an authorized dealer Always disconnect from the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During initial start up some smoke or smell may arise This is a normal p...

Страница 3: ... following CE RoHS standards complying with international standard DMX512 protocol It s available independently controlled and linkable with each other for operation And it is applicable for large scale live performances theater studio nightclubs and discos The ECLISSE INDOOR adopts 1PCS 200W COB LED available for WW which features high brightness and stability Please carefully unpack it when you ...

Страница 4: ...using design 4 Metal spot cutting slots 4 kinds of dimming curve Dimming Frequency 500HZ 25000HZ optional Strobe 1 25times sec High quality optical system Glass asphericalr 1 2 DMX channels Control Protocol RDM DMX Auto run and Master Slave control system LCD with touch screen Low noise fan integrated with copper liquid cooling system Working Temperature 10 40 IP20 protection rating Specifications...

Страница 5: ... the other side to the male 3 pin XLR input of the moving head You can chain multiple Moving head together through serial linking The cable needed should be two core screened cable with XLR input and output connectors Please refer to the diagram below DMX 512 connection with DMX terminator 4 ECLISSE INDOOR PL200 I ...

Страница 6: ... is recommended to use a DMX terminator This helps in preventing corruption of the digital control signal by electrical noise The DMX terminator is simply an XLR plug with a 120 Ω resistor connected between pins 2 and 3 which is then plugged into the output XLR socket of the last fixture in the chain Please see illustrations below 2 1 3 1 2 3 1 Ground 2 Data 3 Data COMMON DMX DMX 120Ω Pin2 Pin3 EC...

Страница 7: ...to the change of temperature Can be Reverse display Multi light working in the same time When using controller to control multi lights to work in strobe the controller just send the channel data The strobe effect will be depend on each light itself And please take attention for the follow situation 1 There will be many situations make the lights are not synchronization in the beginning For example...

Страница 8: ...X Mode Axxx A stand for standard channel mode xxx stand for ID address Dxxx D stand for basic channel mode xxx stand for ID address Manual Mode S MC S stand for stand alone mode MC stand for Mixed Color 6 Reverse Display Running Status Vice Menu Button ECLISSE INDOOR PL200 I ...

Страница 9: ... Single Mode Choice Menu Operation Vice Menu description White Point Press Key of OK to choose mode Choose color temperature Quick Color Same as before Choose inner setting color Mixed Color Same as before Choose the color and strobe setting Status Menu Description Software Name of software Version Version Temperature Show the temperature of lighting fixture DMX Status With OK Slave mode with sign...

Страница 10: ...r Curve Change dimmer curve Standard Incandescent Linear Quick Over Temperature Temperature setting 45 95 Each 5 for increase or decrease Backlight Adjust the display brightness 10 100 Each 5 for increase or decrease Backlight Timeout Screen protect setting No screen protect or black screen from 0 60 second Each 5 for increase or decrease Load Factory Settings Reset ECLISSE INDOOR PL200 I ...

Страница 11: ...Standard channel mode 2CH Chann el Data Function Remark 1 0 255 Dimmer 2 0 10 No function 11 25 5 Strobe speed 255 is the fastest Basic channel mode 1CH Channel Data Function 1 0 255 Color 1 8 ECLISSE INDOOR PL200 I ...

Страница 12: ... Spectrogram CRI Ra 90 Ra 95 9 ECLISSE INDOOR PL200 I ...

Страница 13: ...ere are any damages or severe scratch Make sure the fixture is operated by qualified personnel who knows the fixture before using Keep the original packages if any second shipment is needed Don t try to change the fixtures without any instruction by the manufacturer or the appointed repairing agencies It is not in warranty range if there are any malfunctions from not following the user manual to o...

Страница 14: ...el frame Gel holder is clipped into position correctly and cannot come loose If you are not qualified or have any doubts about hanging the led profile spotlight then do NOT hang it Do not clamp the safety cable to the U bracket or clamp That is not a secondary safety point A secondary safety point is any point that will adequately hold the led profile spotlight if the C clamp or half cheesboro fai...

Страница 15: ...here The fans keep the LED cool and keep the electronics cool too Without the fan working efficiently and dust free the fixtures will fail and that will be a lot more costly than having someone vacuum the fixtures on a regular basis How often should the fans be cleaned It depends on where the fixtures are in a very dusty atmosphere once a week So check the fans on a regular basis they may not need...

Страница 16: ...Voltage LEDs IP Rating T Color Working Position CRI Housing Cooling System DMX Control DMX Channels Weight Dimension Warranty 100V 240V 50 60Hz 200W COB LED IP20 Warm White Any safe working position 90 Die casting aluminum housing design Low noise fan integrated RDM DMX Auto run and Master Slave 1 2CH Manual zoom 25 50 11 4Kgs 820 D 330 W 315 H mm 2 Year https www piu39av com pluslite lighting ...

Отзывы: