If  optimal  emission  temperature  causes 
excessive  heating  up  of  the  boiler,  it  is  best 
to  store  the  surplus  energy  in  a  thermal 
buffer. If the central heating system does not 
feature a thermal buffer, you such find such 
preset  emission  temperature  at  which  the 
temperature  of  water  in  the  boiler  is  at  the 
desired  level.  If  it  is  too  hot  in  a  room, 
decrease  the  preset  emission  temperature, 
and  increase  it  in  the  opposite  case.  The 
preset boiler temperature is in this method of 
secondary importance, it prevents exceeding 
undesirable  temperature  of  the  boiler.  It  is 
recommended 

to 

preset 

the 

boiler 

temperature  as  10°C  higher  than  the 
expected  boiler  temperature  after  the 
emission temperature settles. After the boiler 
reaches  the  preset  temperature,  the 
regulator  switches  to  the  SUPERVISION 
mode.  

 

High  emission temperature, even if 
the  fan  rotates  slowly,  can  mean 
that the boiler is contaminated – in 
such case, it should be cleaned.

 

Before enabling  this mode for the first time, 
it  is  recommended  to  program  the  regulator 
in accordance with point 11.9 

 

Caution: 

the 

regulator 

will 

automatically 

switch 

from 

regulation mode 3 to mode 1, if the 
emission  sensor  is  damaged  or  if 
the  emission  temperature  exceeds 
the  emission  sensor  measuring 
capacity.  Therefore,  it  is  important 
to  set  proper  parameters  for  the 
regulator  to  operate  in  mode  1, 
without causing any danger. 

7.8

 

SUPERVISION 

The  regulator  switches  to  the  SUPERVISION 
mode in the following circumstances: 
a)

 

In the case of CLASSIC and PID 
EMISSION modes of regulation – if the 
boiler temperature exceeds the preset 
boiler temperature,

 

  

b)

 

In the case of PID mode of regulation – if 
the boiler temperature exceeds the 
preset boiler temperature by 

+

10°C. 

In the SUPERVISION mode the fan is enabled 
cyclically  for  short  periods,  in  order  to 
prevent  the  fire  from  going  out  and  to 
remove accumulated combustible gases from 

the  boiler  furnace  chamber.  The  fan  is 
enabled  for 

blow-off  time 

at  every 

blow-off 

interval. 

These  times  must  be  selected  in 

such a way that the boiler furnace did not go 
out  and,  at  the  same  time,  to  prevent  the 
boiler temperature from increasing. 

 

Incorrect  selection  of  blow-off 
parameters  can  cause  boiler 
overheating. 

7.9

 

Settings for hot utility water 

The device  regulates the temperature of the 
hot  utility  water  tank,  provided  that  a  hot 
utility 

water 

temperature 

sensor 

is 

connected.  Using  the 

hot  utility  water  mode  

parameter 

, the user can: 

 

set the hot utility water priority (

HUW 

mode

 =1) – the central heating pump 

is  disabled  to  fill  the  hot  utility  water 
tank faster  

 

set  simultaneous  operation  of  central 

heating  and  hot  utility  water  pump 
(

HUW mode

 = 2),  

 

enable the SUMMER function (

HUW

 

mode = 3), 

 

disable tank filling (

HUW

 mode =4), 

 

If the hot utility water sensor is 
disconnected, the 

hot utility water 

mode 

user parameter cannot be 

changed.

 

7.10

 

Enabling the SUMMER function 

In  order  to  enable  the  SUMMER  function, 
which allows to fill the hot utility water tank 
in the summer without the need of warming 
the  central  heating  system,  set  the 
parameter 

hot utility water mode 

= 3. 

 

Do  not  enable  the  SUMMER  function  if 
the 

hot 

utility 

water 

pump 

is 

disconnected.  

 

The  SUMMER  function  cannot  be 
enabled  if  the  hot  utility  water  sensor  is 
disconnected.

 

 

The  SUMMER  function  can  be  enabled 
only after making sure that the boiler will 
not overheat. If the SUMMER function is 
enabled,  the  heat  consumption  is  much 
lower, because the central heating pump 
is inactive. The method of decreasing the 
boiler  overheating  is  described  in  point 

Содержание ecoMAX 200 W

Страница 1: ...oiler regulator ecoMAX 200 W FOR SOLID FUEL BOILERS WITH A FAN OPERATION AND MAINTENANCE MANUAL ISSUE 1 3 APPLICABLE TO SOFTWARE 10 034 10 035 10 036 2010 04 14 Dzia Zintegrowanego Systemu Zarz dzania...

Страница 2: ......

Страница 3: ...1 CONNECTING TEMPERATURE LIMITER STB 20 11 12 CONNECTING ADDITIONAL THERMAL PROTECTION 20 11 13 SMOOTH FAN START 20 12 Service settings 21 12 1 CENTRAL HEATING PUMP ACTIVATION TEMPERATURE N0 21 12 2 B...

Страница 4: ...erature limiter Therefore it cannot be used instead of a safety temperature limiter The value of the programmable parameters should be selected appropriately to the parameters of the given boiler and...

Страница 5: ...rtable temperature in the heated rooms 3 Information about documentation The regulator manual is a supplement for the boiler manual In particular except for this manual the boiler manual should also b...

Страница 6: ......

Страница 7: ...REGULATOR INSTRUCTION MANUAL ecoMAX 200 W...

Страница 8: ...ng the preset boiler temperature due to hot utility water heating 10 signal decreasing the preset boiler temperature due to operation of the room thermostat 11 service menu symbol 12 hot utility water...

Страница 9: ...l the arrow is in the boiler regulation mode position Use or buttons to set value The method is based on the T1 boiler indication and consists in decreasing of the airflow power from Maximum revolutio...

Страница 10: ...the PID EMISSION mode Moreover after equipping the regulator with an emission sensor it is possible to enable very fast detection of fuel shortage This provides additional saving of heat energy resul...

Страница 11: ...temperature exceeds the preset boiler temperature by 10 C In the SUPERVISION mode the fan is enabled cyclically for short periods in order to prevent the fire from going out and to remove accumulated...

Страница 12: ...e regulator outputs The window shown at Drawing 5 appears and the central heating pump symbol flashes first Drawing 5 Manual control Press START and STOP to change the status of the given output START...

Страница 13: ...REGULATOR INSTALLATION AND SERVICE SETTINGS MANUAL ecoMAX 200 W...

Страница 14: ...d by the regulator where 1 ecoMAX 200 regulator 2 central heating pump 3 hot utility water pump 4 fan 5 room thermostat 6 hot utility water tank 7 central heating system 8 chimney duct 9 boiler T1 boi...

Страница 15: ...of 15 60 C During transport the device cannot be exposed to vibrations greater than those typical of normal road transport 11 Regulator installation 11 1 Environmental conditions Due to the risk of ex...

Страница 16: ...ermal conditions and safety issues a safe distance between active parts of the terminals and the conductive metal elements of the enclosure must be kept Drawing 10 Metal elements of the regulator encl...

Страница 17: ...d with an arrow Drawing 12 Diagram of electric connections with external devices where T1 boiler temperature sensors type CT4 T2 hot utility water temperature sensors type CT4 T3 emission temperature...

Страница 18: ...at least 0 5mm2 Total length of the sensor leads cannot exceed 15 m The boiler temperature sensor CT4 should be fitted in the thermometric pipe situated in the boiler shell Hot utility water temperatu...

Страница 19: ...be filled via hot utility water pump select the hot utility water pump operation mode acc to point 7 9 11 10 Connecting room thermostat To make the boiler more economical and the temperature in the h...

Страница 20: ...l order It cuts off the fan power supply Sensor of the additional thermal protection which operates on low safe voltage should be placed in the thermometric pipe of the water jacket You should provide...

Страница 21: ...eating pump is activated This protects the boiler against retting caused by its being cooled down by hot water returning from the system Disabling the central heating pump on its own does not guarante...

Страница 22: ...e in the heated rooms will drop and the boiler will reach the preset temperature faster and switch to the SUPERVISION mode Yet too long a blockade of the central heating pump will cause the system to...

Страница 23: ...the hot utility water pump when the central heating pump is disabled In order to cool the boiler down operation of the hot utility water pump can be extended by the time r4 Extending hot utility wate...

Страница 24: ...he cases of power supply failure the regulator will resume the operation mode in which it was before the failure 13 Firmware WARNING Values of the following parameters can be modified only by qualifie...

Страница 25: ...threshold Thanks to this a momentary exceeding of the boiler temperature will not cause stoppage of the boiler Before the boiler reaches the P0 temperature the regulator will attempt to drop the exces...

Страница 26: ...temperature limiter STB input jumper is on terminals 1 2 the jumper should be placed only if no temperature limiter is connected check if the additional thermal protection sensor input jumper is on te...