background image

WARNINGS AND IMPORTANT INFORMATION 

READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.

Failure to carefully read and follow all instructions in this manual can result in equipment malfunction, property damage, 
personal injury and/or death.

WARNINGS: 

 

WHEN IGNORED, CAN RESULT IN SERIOUS INJURY OR DEATH.

CAUTIONS: 

 

WHEN IGNORED, CAN RESULT IN MINOR INJURY OR PRODUCT DAMAGE.

SHALL/MUST/

IMPORTANT: 

  INDICATES A MANDATORY REQUIREMENT OF THIS MANUAL.

SHOULD: 

 

INDICATES A RECOMMENDED REQUIREMENT OF THIS MANUAL.

 

 

Any deviations from these instructions may, at the discretion of Rinnai, void the warranty. As a result, the  

 

 

customer and/or installer may be charged a fee for product non-warranty related call outs. Also, note that  

 

 

failure to comply with these instructions may preclude Rinnai from being able to service the unit.

DISCLAIMER: 

  This document is a guide only. Laws, regulations and industry standards can vary between States and    

  Territories.

  

 

Accordingly, this guide MUST BE read in conjunction with, and subject to, all laws, regulations and industry  

 

 

standards applicable in the State or Territory in which the products are installed. 

 

 

You MUST ensure that the installation of the products will comply with those laws, regulations and  

 

 

 

standards, and that the products recommended to customers are fit for the purpose for which they are  

  intended.

REGULATORY / INSTALLATION / SAFETY

This appliance 

SHALL BE

 installed in accordance with:

 

 

Manufacturer’s Installation Instructions.

 

 

Current AS/NZS 3000 (electrical codes).

 

 

Local Regulations and Municipal Building Codes including local OH&S requirements.

 

 

Local water authority regulations

 

 

Duct fixing regulations, EPA guidelines and AS HB276-2004 “A Guide to Good Practice”

  ALWAYS

 comply with the following precautions to avoid dangerous situations and to ensure optimum   

  performance.

  This 

appliance 

MUST BE 

installed, maintained and removed by an Authorised Person.

  DO 

NOT

 place any articles on or against this appliance

  DO 

NOT

 use or store flammable materials near this appliance

  DO 

NOT

 spray aerosols in the vicinity of this appliance while it is in operation

  DO 

NOT

 modify this appliance

 

 

This appliance is intended to be permanently connected to the water mains and 

NOT

 to be connected by a  

  hose-set.

 

 

If the supply cord is damaged, it 

MUST BE

 replaced by manufacturer, its service agent or similarly qualified  

 

 

persons in order to avoid a hazard.

 

 

This evaporative cooler is 

NOT

 intended to be installed in a BAL-12.5.to 29 area.*

 

 

This appliance is 

NOT

 intended for use by persons (including children) with reduced physical, sensory    

 

 

or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or  

 

 

instruction concerning use of the appliance by a person responsible for their safety.

 

 

Children should be supervised to ensure that they 

DO NOT

 play with the appliance.

*Except for AD Models.

Содержание Brivis AD AD66

Страница 1: ...Evaporative Cooling Operation Manual Brivis Contour Series Brivis Promina Series Brivis Advance Series Brivis AD Series...

Страница 2: ...intended REGULATORY INSTALLATION SAFETY This appliance SHALL BE installed in accordance with Manufacturer s Installation Instructions Current AS NZS 3000 electrical codes Local Regulations and Municip...

Страница 3: ...rivis Promina Series P36 P46 P56 P66 P76 Brivis Advance Series F36D F56D F76D Brivis Advance Plus F45DS F66DS F86DS Brivis AD Series AD66 AD66D AD86 AD86D Brivis AD BAL Series AD56 AD56D AD66 AD66D AD...

Страница 4: ...provided by various openings when fully opened NOTE You can also choose to have these openings only halfway open However the opening will only provide half the amount of ventilation shown and addition...

Страница 5: ...ING VENT S LOCATION Vents should be set up so the air is directed across the ceiling However they should not be restrictive and the vents should also be directed to disperse air evenly around the room...

Страница 6: ...re Wet which shows Pre Wetting cooler pads Please Wait 1 9 2 6 5 3 8 14 15 16 17 18 7 4 12 10 13 11 NETWORKER WALL CONTROL OPERATION NETWORKER WALL CONTROL OPERATION ABOUT YOUR BRIVIS NETWORKER WALL C...

Страница 7: ...in more efficient saturation of the Cooler filter pads and a cooler outlet air temperature 1 6 7 13 11 NETWORKER WALL CONTROL OPERATION AUTOMATIC PRE WET When the Cooler is turned ON with both the fan...

Страница 8: ...The message PreWetting cooler pads Please Wait will scroll across the display It will take approximately 8 minutes for the unit to complete the pre wet before the fan will turn on On days of high hum...

Страница 9: ...imer 5 Press the PROG 5 button to exit and save your setting CHECKING YOUR TIMER SETTINGS Once Timer settings are made you can review or cancel them in a number of methods The LCD screen 13 displays O...

Страница 10: ...t Brivis Service If the Cooler is still operating but the Brivis Networker is showing an error message try pushing the Key 4 17 to clear the fault If the fault persists contact Brivis Service If the C...

Страница 11: ...PIN 1 Press the FUNCTION button 2 followed immediately by Key 2 15 The screen will then display Enter Your PIN number to lock the system DO NOT ENTER NUMBERS AT THIS STAGE AND CONTINUE TO THE NEXT STE...

Страница 12: ...for the word Clock 30 beside Key 5 18 while both the Brivis Networkers are in the off position BATTERIES The Brivis Networker requires no batteries If the Brivis Networker has no screen check your 24...

Страница 13: ...ent door and or windows have been opened Refer to exhaust requirements covered in Before Operating Your Evaporative Cooler The padlock is appearing on the screen This indicates that the child proof lo...

Страница 14: ...the unit is on A All Brivis AD models use the bleed off method for tank water quality control This bleed off will continually rid the cooler of any salt or sediments and allow for the tank to be cont...

Страница 15: ...r installer in the first instance Q Can I run heating through the same ductwork as my evaporative cooler A No the differing technology between ducted heating and evaporative cooling doesn t allow the...

Страница 16: ...with your Networker wall controller a service call is required Q We have a unit with a Brivis Networker Wall Controller How is the LED screen backlight activated without changing any setting Is there...

Страница 17: ...lled 6 Normal Business Hours means 8 30am to 5 00pm Monday to Friday excluding public holidays 7 Operating Installation Instructions means the user manual or other documentation which provides detaile...

Страница 18: ...repair or replacement shall be performed during Normal Business Hours by anAuthorised Service Representative Repair by persons other than anAuthorised Service Representatives may void the Warranty 2...

Страница 19: ...ding but not limited to faulty or poor external electrical wiring incorrect or faulty power supply voltage fluctuations over voltage transients or electromagnetic interference inadequate or faulty gas...

Страница 20: ...chaser pays for the relevant freight charges in transit insurance expenses or travelling costs without written authorisation from Rinnai Rinnai will not reimburse the Purchaser for such costs 6 3 The...

Страница 21: ...ce Avenue Point Cook Victoria 3030 PO Box 6014 Point Cook Victoria 3030 Tel 03 8360 9622 03 5292 2219 Monday to Friday 9 00 am to 5 00 pm EST Saturday 9 00 am to 1 00 pm EST For further information vi...

Отзывы: