SQF-4-5
T
rouble-
shooting
12 February 2007
FAULT CODE DESCRIPTION
SQF-010
Fault code SQF-010, indicates that the Roller motor (SQF-M4) has a short circuit.
Initial Actions
Check Fuse F2 on the Squarefolder Transformer.
Procedure
Disconnect the motor plug M4. Run the Diagnostics again.
Fault code SQF-012 (Open circuit) is displayed?
Y
N
Disconnect plug D.P2 from PCB ”D”. Check wires for Short circuit across the leads of the Orange wire M4 to
D.P2-12 (violet) and the Violet wire M4 to D.P2-3 (orange).
Is there Short circuit?
Y
N
Replace PCB ”D”.
Replace wire Harness.
Replace motor SQF-M4.
SQF-011
Fault code SQF-011, indicates that the Roller motor (SQF-M4) has an Open circuit.
Initial Actions
Check Fuse F2 on the Squarefolder Transformer.
Procedure
Disconnect the motor plug M4. Disconnect plug D.P2.
Is there Continuity and no Short circuit?
Y
N
Replace wire Harness.
1. Replace motor SQF-M4.
2. Replace PCB ”D”.
Содержание SQF-200 SquareFolder
Страница 2: ...SQUAREFOLDER SQF 200 SERVICE MANUAL 12 February 2007 Subject to change ...
Страница 3: ...Page intentionally blank ...
Страница 7: ...Page intentionally blank ...
Страница 9: ...Page intentionally blank ...
Страница 14: ...SQF 3 5 Replacement Adjustment 29 November 2006 E F G Top view Outfeed cover slightly tilted ...
Страница 23: ...Page intentionally blank ...
Страница 39: ...Page intentionally blank ...
Страница 45: ...Page intentionally blank ...
Страница 47: ...Page intentionally blank ...
Страница 49: ...Page intentionally blank ...
Страница 61: ...Page intentionally blank ...
Страница 63: ...Page intentionally blank ...
Страница 65: ...Page intentionally blank ...
Страница 67: ...Page intentionally blank ...
Страница 69: ...Page intentionally blank ...
Страница 83: ...Page intentionally blank ...
Страница 84: ...SQF Wir 1 29 November 2006 Wiring WIRING Squarefolder See pocket at rear of manual for wiring diagrams ...