SQF-3-39
Replacement
Adjustment
29 November 2006
POWER REQUIREMENTS
3.7 POWER REQUIREMENTS
3.7.1 TAPPING THE TRANSFORMER
Purpose
To be able to change the Transformer setting.
Removal
1. Remove Front Cover (
3.1.1 ).
Adjustment
1. Measure the wall outlet voltage.
2. Tap the Transformer to the appropriate setting according to the label on the
Transformer by moving cable [A].
NOTE:
Do not move cable [B].
Replacement
1. Reverse the removal procedure.
[A]
[B]
Transformer in picture tapped for 230V