72
iPORT CL-GigE External Frame Grabber User Guide
To save a configuration change to UserSet1
1.
In the
Device Control
dialog box, make the required configuration changes.
2.
Scroll to the
UserSetControl
section and change the
UserSetSelector
setting to
UserSet1
.
3.
Click
UserSetSave
.
To load the default configuration settings (one-time)
1.
In the
UserSetControl
section of the
Device Control
dialog box, select
Default
in the
UserSetSelector
box.
2.
Click the
UserSetLoad
setting and then click the
UserSetLoad
button that appears to the right.
The default settings are applied to the CL-GigE.
To specify the persistent settings that are loaded every time the CL-GigE is reset
•
In the
UserSetControl
section of the
Device Control
dialog box, select a User Set in the
UserSetDefaultSelector
box and then close the
Device Control
dialog box.
The next time the CL-GigE is reset or power cycled, the User Set that you selected is loaded.
Ensuring Configuration Settings are not Overwritten
When you choose a method to save eBUS Player and CL-GigE settings, you could overwrite previously
configured settings. You should consider the following when saving settings.
•
Each newly applied .pvcfg file overwrites all settings configured by a previously applied .pvcfg file.
•
Each newly applied .pvcfg file overwrites the settings from a previously applied User Set.
•
When you apply CL-GigE settings from a User Set, device settings configured by a previously
applied .pvcfg are overwritten.
Saving the CL-GigE XML File to your Computer
You can save the CL-GigE XML file to your computer.
To save your camera’s XML file
1.
Click
Tools
>
Save GenICam XML
.
2.
Navigate to the location in which you want to save the XML file.
3.
Click
Save
.
This allows you to view the CL-GigE’s GenICam XML file; it does not save your eBUS Player or camera
settings.