background image

 

 

TC-SPD2000 

DT Istr (TC-SPD2000) 05/18 – Rev 0_05/2018                                                                  

 

               

13/16

 

 

The appliance turns on and the display will show "- -" in this mode is  
emitted cold air. 
Pressing the same button, the fan heater turns off automatically after 30 sec. 
Select using the button       the desired power heat  
(     = 1000W,         = 2000W).  
While the fan heater is in operation, with the button      you can set the operating time (from a minimum of 1 h 
up to a maximum of 12 h). 
While the fan heater is operating press the button      to activate the swing, press the same button to stop it. 

1) Set the time /current day 

Press the button     once and the display will show "12", press     /     to set the hour.  
Press     again and the display will show "30", press     /      to set the minutes.  
Press a third time     to set the day of the week, always using the buttons     /     ,  
then press     to confirm. (NB. If the device is turned off or is disconnected the plug the time will reset) 

2) Set the temperature 

During operation press    /    to set the temperature (10 - 49°C) and then press     to confirm. 
After you set the temperature, the device will enter in "SMART MODE". 
If T - T environment >2°C Operates at 2000W 
If T - T environment <2°C Operates at 1000W 
If T - T environment =0°C standby mode (turns on automatically with the temperature differences) 

3) Set the weekly program 

After you have set the time/current day, press the button     , press     to scroll through the weekly days selecting 
on the display the desired day (D1-D7), press     and the display will show P1-P6 (programs), press      to set the 
turn on desired time, press     to set the torn off time desired and then press     . 

Detecting open windows 

During operation, press       , the display will show the temperature, adjust it with     /     . 
In this mode if the temperature drops of 5-10°C in less than 10 minutes the appliance will enter into standby 
mode in 30 minutes, press       again to turn on again the appliance. To turn off the mode then repress       . 

LOCATION OF THE APPLIANCE: 
Wall mounting 

The  unit  must  be  fixed  to  the  wall.  Make  sure  that  the  opening  of  the  air  inlet  is  facing  downward.  The 
appliance must be placed at a minimum height of 1.8 meters from the ground. Create two holes (same diameter 
dowels)  on  the  wall  at  the  distance  indicated  in  the  DIMA  present  inside  the  packaging  (39.8  cm).  Insert  the 
screws into the anchors and hang the fixture. 
The air outlet  grid should have a minimum clearance of 1 m,  while lateral  sides must have a free space  of at 
least 40 cm. 
WARNING: The appliance must be installed so that switches and other control devices can not be touched by a 
person who is in the bathtub or in the shower. 

 
SAFETY MEASURES

 

To  avoid  damages  and  dangerous  situations  caused  by  overheating,  the  fan  heater  is  equipped  with  a  safety 
device that stops its  operation in  case of overheating, for example, due to a total  or partial  obstruction of the 
grills. In this case, disconnect the appliance from the mains socket, wait for around 30 minutes so that it cools 
down,  and  remove  the  object  that  is  obstructing  the  grills.  At  this  point,  it  is  possible  to  start  the  appliance 
again, as described above. The appliance should operate correctly. Should the problem come up again, contact 
the nearest support centre.

 

MAINTENANCE 

 

1.

 

This appliance requires no maintenance except cleaning of its external surfaces.  

2.

 

Before cleaning the appliance, disconnect it from the mains socket and wait for it to cool down.  

3.

 

Dust the intake grill regularly, removing threads, down or any other foreign matter that might limit regular 
air circulation. 

4.

 

To clean external surfaces, use only a soft cloth moistened with water, and do not use solvents. 

5.

 

Do not throw the box, use it to store the equipment. 

6.

 

When you don’t use the appliance, store it in its original packaging and store in a dry place. 

 
INSTRUCTIONS FOR DISPOSAL 

 

Disposal of this product shall be governed by the European Community Directive 2012/19/UE on Waste 
Electrical  and  Electronic  Equipment  (WEEE).  According  to  this  regulation,  the  consumer  has  the 
obligation NOT to dispose of this product as household waste but through separate channels of collection 

Содержание TC-SPD2000

Страница 1: ...000 DT Istr TC SPD2000 05 18 Rev 0_05 2018 1 16 TERMOVENTILATORE CERAMICO SOUFFLANT CERAMIQUE CERAMIC FAN HEATER IT ISTRUZIONI PER L USO FR MODE D EMPLOI GB INSTRUTIONS MANUAL MODELLO MODELE MODEL TC...

Страница 2: ...endaggi materiali combustibili esplosivi mobilio ecc 5 L impiego sicuro comporta il rispetto di alcuni basilari accorgimenti di sicurezza tra i quali non azionare l apparecchio con le mani o piedi bag...

Страница 3: ...con quelle indicate sulla targhetta tecnica del prodotto 2 Questo apparecchio dovr essere collegato ad una presa di corrente approvata secondo le norme di sicurezza degli impianti elettrici di tipo ci...

Страница 4: ...essa aria fredda Premendo lo stesso pulsante il termoventilatore si spegne in automatico dopo 30 sec Selezionare tramite il pulsante la potenza di calore desiderata 1000W 2000W Mentre il termoventilat...

Страница 5: ...e possono limitare la normale circolazione dell aria 4 Per la pulizia delle superfici esterne utilizzare esclusivamente un panno morbido inumidito con acqua e non usare solventi 5 Non gettare la scato...

Страница 6: ...i controllo a distanza NO con controllo di avviamento adattabile NO con limitazione del tempo di funzionamento SI con termometro a globo nero NO Contatti Kemper srl Via Prampolini 1 Q 43044 Lemignano...

Страница 7: ...tions quant l utilisation de l appareil en toute s curit et qu ils comprennent bien les dangers encourus Les enfants ne doivent pas utiliser l appareil comme un jouet Le nettoyage et l entretien par l...

Страница 8: ...our d brancher l appareil s lectionner le bouton 1 et d brancher la fiche de la prise de courant MANUEL D UTILISATION Connecter l appareil une prise lectrique et appuyer sur la touche 0 I sur le c t d...

Страница 9: ...u esur les c t s l espace libre doit tre d au moins 40 cm AVERTISSEMENT L appareil doit tre install de telle sorte que les interrupteurs et les autres commandes ne peuvent pas tre touch s depuis la ba...

Страница 10: ...r ception d informations sur la temp rature de la pi ce et ou ext rieure NO Consommation d lectricit auxiliaire puissance thermique r gulable par ventilateur NO la puissance thermique nominale elmax 0...

Страница 11: ...not used and before any maintenance operation the appliance must always be unplugged 7 If the power cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualifi...

Страница 12: ...of children 7 Never connect the power cord to extensions or triple plugs Do not pull or damage the power cord Before any maintenance operations disconnect the plug from the mains socket 8 The power co...

Страница 13: ...he wall Make sure that the opening of the air inlet is facing downward The appliance must be placed at a minimum height of 1 8 meters from the ground Create two holes same diameter dowels on the wall...

Страница 14: ...eedback NO Maximum continuous heat output Pmax c 2 0 kW electronic heat charge control with room and or outdoor temperature feedback NO Auxiliary electricity consumption fan assisted heat output NO At...

Страница 15: ...TC SPD2000 DT Istr TC SPD2000 05 18 Rev 0_05 2018 15 16 Remote control Il significato del simbolo NON COPRIRE La signification du symbole est NE PAS COUVRIR The meaning of figure is DO NOT COVER...

Страница 16: ...5 2018 16 16 Importato e distribuito da Importe and distribu par Imported and distributed by KEMPER s r l Via Prampolini 1 Q 43044 Lemignano di Collecchio Parma ITALY Tel 39 0521 957111 Fax 39 0521 95...

Отзывы: