REMOTE CONTROL OPERATION

 

 

 

 

 

 

 

 

 

MULIT-FUNCTION WIRELESS REMOTE CONTROL SYSTEM 

FOR OPERATING A LATCHING SOLENOID VALVE, MANUALLY OR WITH A THERMOSTAT FUCTION 

 

 

 

 

 

INTRODUCTION 

This  remote  control  system  was  developed  to  provide  a  safe,  reliable,  and  user-friendly  remote  control  system  for  gas  heating 

appliances.  The system is operated manually from the transmitter.  The system operates on radio frequencies (RF) within a 20-feet 

range using non-directional signals.  The system operates on one of 1,048,576 security codes that are programmed into the transmitter 

at the factory; the remote receiver's code must be matched to that of the transmitter prior to initial use.  

 

 

Review COMMUNICATION SAFETY under GENERAL INFORMATION section.  This safety feature shuts down 

the appliance when a potentially unsafe condition exists. 

 

 

 

TRANSMITTER 

 

This remote control SYSTEM offers the user a battery-operated remote control to 

power  a  latching  solenoid  such  as  those  used  with  gas  valves  used  in  some 

heater rated gas logs, gas fireplaces and other gas heating appliances. 

 

The  solenoid  circuit  uses  the  battery  power  from  the  receiver  to  operate  a 

solenoid.  The circuit has reversing polarity software which reverses the positive 

(+)  and  negative  (-)  output  of  the  receiver's  battery  power  to  drive  a  latching 

solenoid ON/OFF. The SYSTEM is controlled by the remote transmitter. 

 

The transmitter operates on a (2) 1.5V AAA batteries.  

 

ALKALINE batteries should always be used for longer battery life and maximum 

operational performance. Re-chargeable batteries should not be used. 

 

Before  using  the  transmitter,  install  the  (2)  AAA  transmitter  batteries  into  the 

battery  compartment.  (Use  caution  that  batteries  are  installed  in  the  proper 

direction) 

 

 

 

 

 

KEY SETTINGS 

 

 

ON      - Operates unit to on position, Manually operated solenoid ON. 

      OFF      - Operates unit to off position, Manually operated solenoid OFF. 

      MODE  - Changes unit from manual mode to thermo mode. 

      SET      - Sets temperature in thermo mode. 

 

 

 

 

 

 

 

 

 

 

 

ON

MODE

OFF

SET

1

2

3

4

 

ON

MODE

OFF

BUTTON

WALL CLIP

SLOT

BATTERY

COMPARTMENT

FRONT

BACK

OFF

SET

ON

BUTTON

MODE

BUTTON

SET

BUTTON

 

IF YOU CANNOT READ OR UNDERSTAND THESE INSTALLATION INSTRUCTIONS DO NOT 

ATTEMPT TO INSTALL OR OPERATE  

Содержание VFL2-MO24DR

Страница 1: ... do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Pr...

Страница 2: ...nob will not push in or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water BATTERY INSTRUCTIO...

Страница 3: ... supplier If pilot goes out repeat steps 3 through 7 Wait 1 minute before attempting to light pilot again If after several tries the pilot still goes out turn the gas control knob clockwise to the OFF position and call a qualified service technician 8 Turn control knob counterclockwise to the ON position 9 To use the included thermostatic remote control set receiver switch to the REMOTE position S...

Страница 4: ...r rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which reverses the positive and negative output of the receiver s battery power to drive a latching solenoid ON OFF The SYSTEM is controlled by the remote transmitter The transmitter operates on a 2 1 5V AAA...

Страница 5: ...d TEMP will show Flame icon wil appear on LCD screen in manual on mode OFF OPERATION Press the OFF key the appliance flame will shut off During this time the LCD screen will show OF after 3 seconds the LCD screen will default to display room temperature and the word TEMP will show THERMOSTAT FUNCTION SETTING DESIRED ROOM TEMPERATURE This remote control system can be thermostatically controlled whe...

Страница 6: ...itter has ON and OFF manual functions that are activated by pressing either button on the face of the transmitter When a button on the transmitter is pressed the word ON or OF will appear on the LCD screen to show while the signal is being sent Upon initial use there may be a delay of three seconds before the remote receiver will respond to the transmitter This is part of the system s design POWER...

Страница 7: ...IMPORTANT Like any piece of electronic equipment the remote receiver should be kept away from temperatures exceeding 130º F inside the receiver case Battery life is also significantly shortened if batteries are exposed to high temperatures HEARTH MOUNT The remote receiver can be placed on the fireplace hearth or under the fireplace behind the control access panel Position where the ambient tempera...

Страница 8: ...ivate the LOCK OUT feature press and hold the ON button and the MODE button at the same time for 5 seconds The letters CP will appear in the TEMP frame on the LCD screen To disengage the LOCK OUT press and hold the ON button and the MODE button at the same time for 5 seconds and the letters CP will disappear from the LCD screen and the transmitter will return to its normal operating condition To v...

Страница 9: ...erly Check battery in TRANSMITTER to ensure contacts are touching and ends of battery Bend metal contacts in for tighter fit Be sure RECEIVER and TRANSMITTER is within 20 feet operating range Clear Codes Memory in the receiver might be full if the learn button is pressed too many times If this happens it will not allow any more codes to be learned and no audible beep will be heard To clear memory ...

Страница 10: ...ATTERN Figure 29 shows a correct pilot flame pattern Figure 30 shows an incorrect pilot flame pattern The incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 30 turn heater off see To Turn Off Gas to Appliance page 24 see Troubleshooting page 34 F...

Отзывы: