24
OPERATION
1. STOP! Read the safety information as noted above.
2. Set receiver switch to “ON” position (See Fig. 26).
3. Turn control knob clockwise to the “OFF” position (See Fig. 26).
4. Wait five (5) minutes to clear out any gas. Then smell for gas, including
near the floor. If you smell gas, STOP! Follow “B” in the safety information
as noted above. If you don’t smell gas, go to the next step.
5. Push in slightly and turn control knob counterclockwise to the
“PILOT” position (See Fig. 26). Depress control knob.
6. With control knob depressed, push down on the ignitor button until the
pilot lights. The pilot's location is behind log #3 near the center of the
burner. (See Fig. 27).
7. Keep control knob depressed for (30) seconds after pilot lights. Release
control knob.
• If the control knob does not pop up when released, stop and immediately
call a qualified service technician or gas supplier.
• If pilot goes out repeat steps 3 through 7. Wait (1) minute before attempting
to light pilot again. If after several tries the pilot still goes out, turn the
gas control knob clockwise to the “OFF” position and call a qualified
service technician.
8. Turn control knob counterclockwise to the “ON” position.
9. To use the included thermostatic remote control, set receiver switch to
the “REMOTE” position (See Fig. 28). Press the ON button to turn on the
remote to ignite the main burner. Refer to the remote control instruction
manual on the next page for “MODE” and “SET” functions.
ON
OFF
REMOTE
LEARN
1. Set thermostat to the lowest setting.
2. Press the OFF button on the remote control.
3. Push in slightly and turn control knob clockwise to the “OFF” position.
Fig. 26 - Receiver
& Control Knob
ON
OFF
MODE
SET
Fig. 28 - Remote
Fig. 27 - Pilot
TO TURN OFF GAS TO APPLIANCE
LIGHTING INSTRUCTIONS
WARNING:
Any glass doors shall be completely opened while appliance is in operation.
WARNING:
The fireplace screen must be in place while the appliance is in operation.
A
LP PILOT
A
NG PILOT