background image

24

OPERATION

1. STOP! Read the safety information as noted above.

2. Set receiver switch to “ON” position (See Fig. 26).

3. Turn control knob clockwise         to the “OFF” position (See Fig. 26).

4. Wait five (5) minutes to clear out any gas. Then smell for gas, including 

    near the floor. If you smell gas, STOP! Follow “B” in the safety information

    as noted above. If you don’t smell gas, go to the next step.

5. Push in slightly and turn control knob counterclockwise         to the 

    “PILOT” position (See Fig. 26). Depress control knob.

6. With control knob depressed, push down on the ignitor button until the  

    pilot lights. The pilot's location is behind log #3 near the center of the 

    burner.  (See Fig. 27).

7. Keep control knob depressed for (30) seconds after pilot lights. Release 

    control knob.

• If the control knob does not pop up when released, stop and immediately 

call a qualified service technician or gas supplier.

• If pilot goes out repeat steps 3 through 7. Wait (1) minute before attempting 

to light pilot again. If after several tries the pilot still goes out, turn the

gas control knob clockwise         to the “OFF” position and call a qualified 

service technician.

8. Turn control knob counterclockwise         to the “ON” position.

9. To use the included thermostatic remote control, set receiver switch to 

    the “REMOTE” position (See Fig. 28). Press the ON button to turn on the

    remote to ignite the main burner. Refer to the remote control instruction 

    manual on the next page for “MODE” and “SET” functions.

ON

OFF

REMOTE

LEARN

1. Set thermostat to the lowest setting.

2. Press the OFF button on the remote control.

3. Push in slightly and turn control knob clockwise         to the “OFF” position.

Fig. 26 - Receiver

& Control Knob

ON

OFF

MODE

SET

Fig. 28 - Remote

Fig. 27 - Pilot

TO TURN OFF GAS TO APPLIANCE

LIGHTING INSTRUCTIONS

  

   WARNING: 

Any glass doors shall be completely opened while appliance is in operation.

  

   WARNING: 

The fireplace screen must be in place while the appliance is in operation. 

 

 

A

LP PILOT

 

A

NG PILOT

Содержание VFL2-MO24DR

Страница 1: ... do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Pr...

Страница 2: ...nob will not push in or turn by hand don t try to repair it call a qualified service technician Forced or attempted repair may result in fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water BATTERY INSTRUCTIO...

Страница 3: ... supplier If pilot goes out repeat steps 3 through 7 Wait 1 minute before attempting to light pilot again If after several tries the pilot still goes out turn the gas control knob clockwise to the OFF position and call a qualified service technician 8 Turn control knob counterclockwise to the ON position 9 To use the included thermostatic remote control set receiver switch to the REMOTE position S...

Страница 4: ...r rated gas logs gas fireplaces and other gas heating appliances The solenoid circuit uses the battery power from the receiver to operate a solenoid The circuit has reversing polarity software which reverses the positive and negative output of the receiver s battery power to drive a latching solenoid ON OFF The SYSTEM is controlled by the remote transmitter The transmitter operates on a 2 1 5V AAA...

Страница 5: ...d TEMP will show Flame icon wil appear on LCD screen in manual on mode OFF OPERATION Press the OFF key the appliance flame will shut off During this time the LCD screen will show OF after 3 seconds the LCD screen will default to display room temperature and the word TEMP will show THERMOSTAT FUNCTION SETTING DESIRED ROOM TEMPERATURE This remote control system can be thermostatically controlled whe...

Страница 6: ...itter has ON and OFF manual functions that are activated by pressing either button on the face of the transmitter When a button on the transmitter is pressed the word ON or OF will appear on the LCD screen to show while the signal is being sent Upon initial use there may be a delay of three seconds before the remote receiver will respond to the transmitter This is part of the system s design POWER...

Страница 7: ...IMPORTANT Like any piece of electronic equipment the remote receiver should be kept away from temperatures exceeding 130º F inside the receiver case Battery life is also significantly shortened if batteries are exposed to high temperatures HEARTH MOUNT The remote receiver can be placed on the fireplace hearth or under the fireplace behind the control access panel Position where the ambient tempera...

Страница 8: ...ivate the LOCK OUT feature press and hold the ON button and the MODE button at the same time for 5 seconds The letters CP will appear in the TEMP frame on the LCD screen To disengage the LOCK OUT press and hold the ON button and the MODE button at the same time for 5 seconds and the letters CP will disappear from the LCD screen and the transmitter will return to its normal operating condition To v...

Страница 9: ...erly Check battery in TRANSMITTER to ensure contacts are touching and ends of battery Bend metal contacts in for tighter fit Be sure RECEIVER and TRANSMITTER is within 20 feet operating range Clear Codes Memory in the receiver might be full if the learn button is pressed too many times If this happens it will not allow any more codes to be learned and no audible beep will be heard To clear memory ...

Страница 10: ...ATTERN Figure 29 shows a correct pilot flame pattern Figure 30 shows an incorrect pilot flame pattern The incorrect pilot flame is not touching the thermocouple This will cause the thermocouple to cool When the thermocouple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 30 turn heater off see To Turn Off Gas to Appliance page 24 see Troubleshooting page 34 F...

Отзывы: