12
INSTALLATION
FIREPLACE CLEARANCES
CAUTION: If you install the fireplace in a home garage
• fireplace pilot and burner must be at least 18" above floor.
• locate fireplace where moving vehicle will not hit it.
For convenience and efficiency, install fireplace
• where there is easy access for operation, inspection and service
• in coldest part of room
• If this appliance is to be installed directly on carpeting, tile or other combsutible material, other than
wood flooring, the appliance must be installed on a metal or wood panel extending the full width and
depth of the appliance.
An optional blower kit is available from your retailer. See Accessories, page 36. If planning to use
blower, follow instructions provided with blower for power source.
Minimum Clearances For Side Combustible Material, Side Wall and Ceiling
A. Clearances from the side of the fireplace cabinet to any combustible material and wall should
follow diagram in Figure 6.
B. Clearances from the top of the fireplace opening to the ceiling should not be less than 36".
6’’
Either
Side
Min.
36’’
Fig. 6 - Minimum Clearance to
Combustible Material
Min.
36''
36''
6''
Either
Side
6''
• This firebox is only for use with the mantel provided.