21
• Fit a Male Threaded Union to the filter valve
marked “pool” or “return”.
• If you are using a heater fit a Male Threaded Union
to the heater inlet.
[See Figure D07]
• Fit pipe between the Unions on the filter and
heater.
• On the outlet of the heater fit a Male Threaded
Union and then a Double Union Ball Valve.
[See
Figure D08]
• Fit a male threaded union into the back of the
return inlet that you have fitted into the pool wall.
[See Figure D09]
• Fit pipe between the return union and the heater
valve.
[See Figure D10]
• If you are not using any heating fit the valve just
after the filter and run pipe directly to the return
inlet union.
• When you have assembled the above pipe work
and are happy with the layout glue the joints as per
the instructions.
[See Figure D11]
• Fit a hose tail pipe fitting into the connection on the
filter valve marked “waste” or “backwash”. Use a
jubilee clip and fix the flexible backwash hose onto
the hose tail.
[See Figure D12]
• Allow the glue to set over a few hours or overnight
before allowing water into it and turning on the
pump. Refer to the Wooden Pool Operating and
Maintenance Manual.
Figure D10
Figure D11
Figure D12
Figure D07
Figure D08
Figure D09