WIRELESS CONTROL CONFIGURATION
1.
To start the configuration, select
Wi-Fi CONFIG
in the menu. Time to finish the configuration is 5 minutes.
2.
Enable Wi-Fi connection in your mobile device and connect to
planika123
network (if the network is not visible on the
list, disconnect the power supply from the device for 10 seconds and start the configuration again).
3.
Open the browser in your mobile device and enter ‘
planika.net
’. A control panel will appear.
4.
Go to
SETTINGS
. Choose the connection mode (
MODE)
and security protocol (
SECURITY
). Enter the network
name (
SSID_NAME
) and password (
PASSWORD
). Accept your settings by pressing
submit
.
5.
Connect to the selected/created network in the Wi-Fi menu in your mobile device.
6.
Read the IP address (
Device IP
) in the device menu and enter it in the browser in your mobile device. A control
panel will appear.
ERRORS
The errors are accompanied by a sound signal. Press
START/STOP
to mute or turn the device OFF by pressing
.
ERROR
SOLUTION
(contact the Service Department if the solution does not eliminate the error)
TEMPERATURE TOO HIGH
Wait for
READY
.
DEVICE HIT
DEVICE TILTED
CO2 LEVEL TOO HIGH
Ventilate the room to reduce the CO
2
level. Wait for
READY
.
WARNING CLOSE THE LID
Do not fill the fuel. Close the fuel inlet lid.
CHECK THE TANK WIRE
CONNECTION
Disconnect the fuel tank wires and connect them again. (FLA 3 XL)
ERROR 01
Fuel spillage has been detected. Turn the device OFF by pressing
and disconnect the pump. Wipe the visible liquid and wait for min. 1 hour.
If the error is not eliminated, wait for min. 24 hours.
ERROR 05
The device has been moved. Eliminate the source of shock. Wait for
READY
.
ERROR 06/16/17/20
Turn the device OFF
, wait for min. 5 minutes and turn the device ON.
ERROR 15
Turn the device OFF
and level the surface on which the device is installed.
ERROR 21
Turn the device OFF
and ON. Wait for
READY
.
ERROR
02/03/04/10/16/31/32/41/51/61
Contact the Service Department.
FUEL
Use only fuels consisting of
86-96,6%
ethanol by volume. FANOLA
®
is the recommended fuel. Do not use gel, thick and
viscous fuels or fuels of improper electric conductivity. The values must be compliant with those of FANOLA
®
. Other
fuels, such as dehydrated ethanol (i.e. consisting of more than 96,6% by volume ethanol) will cause a device error and
loss of the guarantee.
Fuels consisting of 100% by volume ethanol will damage the device.
CLEANING
–
Clean with a damp cloth and delicate detergents, only when the device is turned off and cooled.
SERVICE
–
(keep the provided USB cable for servicing purposes)
www.planikafires.com/service
EN
G
L
ISH
MODE
OFF
Blocks wireless control
via Wi-Fi.
STA
Connection with via your local
network and a router
AP
Direct connection between the
device and your mobile device
(outside your local network)
SECURITY
--
Choose the security protocol used
in your local network
(usually
WPA
/
WPA2
).
Choose security protocol
WPA
(recommended) or
WEP
.
SSID_NAME
--
Enter the name of your local network.
Create a network name.
PASSWORD
--
Enter your local network password.
Create a network password