background image

 

 

- 7 - 

4. 

The  connecting  device,  including  any  network  adapter  is  well  installed  and 
functioning. 

5. 

Confirm  the  connection  distance  is  implemented  within  the  scope  of  operative 
without interference. 

2.2 Rear Panel 

The  rear  panel  of  the  switch  indicates  an  AC  inlet  power  socket,  which  accepts  input 
power from 100 to 240VAC, 50-60Hz, one RS-232 console port for setting up the switch 
via a connection to a terminal or PC using a terminal emulation program, and two slide-in 
slots for installing additional modules. 

25

26

CONSOLE

9600, 8, N, 1

100~240V AC

50 / 60Hz

 

WGSW-2403 Switch rear panel 

Slide-in slots 

The  two  slide-in  slots  on  the  rear  panel  are  reserved  for  following  optional  gigabit 
modules. They can provide fat pipes for up linking to backbone or connecting to servers. 

1000Base-SX

WGSW-D1SX

TX

RX

 

1000BASE-SX : WGSW-D1SX 

 

1000Base-LX

WGSW-D1LX

TX

RX

 

1000BASE-LX : WGSW-D1LX 

1000Base-T

WGSW-D1GT

 

1000BASE-T : WGSW-D1GT 

 

The following is the gigabit module operation and cabling required: 

Media 

Speed 

Duplex Mode  Wiring 

Distance 

10Mbps 

Full / Half 

Category 3,4,5 UTP/STP 

100m 

100Mbps 

Full / Half   

Category 5 UTP/STP 

100m 

1000BASE-T 

1000Mbps 

Full 

Category 5 UTP/STP 

100m 

62.5/125 

µ

m MMF 

220m 

1000BASE-SX 

1000Mbps 

Full 

50/125 

µ

m MMF 

500m 

62.5/125 

µ

m MMF 

550m 

50/125 

µ

m MMF 

550m 

1000BASE-LX 

1000Mbps 

Full 

9/125 

µ

m SMF 

10km 

NOTE:

 MMF-multimode fiber, SMF 

 Single mode fiber 

Содержание WGSW-2403

Страница 1: ...24 port 3 slot Stackable Ethernet Switch WGSW 2403 User s Manual...

Страница 2: ...improvements to this User s Manual and or to the products described in this User s Manual at any time without notice If you find information in this manual that is incorrect misleading or incomplete w...

Страница 3: ...IAL CABLE 11 3 2 TELNET 11 3 3 MAIN MENU 12 CHAPTER 4 WEB MANAGEMENT 15 4 1 START A WEB BROWSER SESSION 15 4 2 STACK MAIN PAGE 16 4 3 SWITCH MAIN PAGE 17 4 4 DEVICE CONFIGURATION 20 4 5 TOPOLOGY INFO...

Страница 4: ...bus traffic is separated from the network ports ensuring heavy network loading does not affect management tasks Upto 208 Ethernet ports can be managed by a single IP address The WGSW 2403 can also be...

Страница 5: ...cket Buffer Memory 384K Bytes LEDs System PWR Master Status Per port Speed LNK ACT FDX COL Port Module LNK ACT Stack LNK Cables 10Base T 2 pair UTP Cat 3 4 5 up to 100m 100Base TX 2 pair UTP Cat 5 up...

Страница 6: ...1p QoS RFC 768 UDP RFC 783 TFTP RFC 791 IP RFC 792 ICMP RFC 826 ARP RFC 854 Telnet RFC 2068 HTTP RFC 2236 IGMPv2 Network Management RFC 1157 SNMP v1 v2 RFC 1123 MIB 2 RFC 1493 Bridge MIB Enterprise p...

Страница 7: ...X COL PWR LNK ACT 25 26 LNK ACT FDX COL LNK ACT FDX COL MASTER STATUS 24 port Stackable Ethernet Switch 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 LNK IN OUT STACK Switch ID RESET...

Страница 8: ...e normal Cat 5 or better cable with RJ 45 connector to stack Only straight through UTP STP cable can be used There is no Duplex Mode issue and the maximum distance between first and last switch is 800...

Страница 9: ...apability that is the port can connect either the PC or hub without crossover cable adjustment Wiring for 10 100Mbps Fiber Optic Copper Following are the summaries of cabling required Media Speed Wiri...

Страница 10: ...panel Slide in slots The two slide in slots on the rear panel are reserved for following optional gigabit modules They can provide fat pipes for up linking to backbone or connecting to servers 1000Bas...

Страница 11: ...uired device it means it will not work till it is powered If your networks should active all the time please consider using UPS Uninterrupted Power Supply for your device It will prevent you from netw...

Страница 12: ...t surface with the front facing toward you 3 Locate a mounting bracket over the mounting holes on one side of the unit 4 Insert the screws and fully tighten with a suitable screwdriver 5 Repeat the tw...

Страница 13: ...of the cable in the IN port and the other end to the OUT port of next device Repeat the step for every device in the stack cluster then ending at last switch NOTE Before management stacking be sure o...

Страница 14: ...ection to the device Windows Hyper Terminal program may be a good choice It can be accessed from the Start menu Click START then Programs Accessories and then Hyper Terminal MS DOS based terminal prog...

Страница 15: ...able on telnet and web management interface admin admin can do any configuration except changing password The default password of admin is admin guest guest can view the whole switch information only...

Страница 16: ...r delete the community name IP address and aging time of the trap receivers Up to 5 receivers are supported 5 Management Features Control Enable or disable web telnet and SNMP management function of t...

Страница 17: ...the password of root admin and guest account Only root account has the right to enter this menu 1 System Restart Restart the switch Two options are available cold start and warm start 2 Default Factor...

Страница 18: ...ly install it Note Usually the newer Java TM Virtual Machine is not backward compatible JVM version 1 3 1 is strongly recommended to ensure properly operation The default network configurations are as...

Страница 19: ...g Hardware characteristic Device Name Up time Master and Slave relationship Also by mouse clicking listed items can enter for further operation System Configuration If you are managing a Master or a S...

Страница 20: ...hat Apply applies settings right away but saves the values in the system memory Every time when switch reboots system obtains system parameters from Non volatile Memory you Saved before but not system...

Страница 21: ...ed tool to detect the remote host or IP address exists or not Moreover network status also can be known by the ratio of packets Reply and Loss Telnet By simply clicking the Telnet button the Telnet pr...

Страница 22: ...erver IP field 3 Enter file name in File Name field Click Start button to download the code and system update with it automatically Local File Transfer 1 Select Device ID and Local File Transfer radio...

Страница 23: ...lay Port Status Port Link Down Black Port is not connected or attached device shuts down Port Link Up Green Port links up and working correctly Port Link Up Amber Port links up but in blocking mode Po...

Страница 24: ...become system parameters automatically 4 5 Topology Info This page displays information about the switch es such as Device ID Hardware version Boot Up version POST version Runtime version Firmware ve...

Страница 25: ...Click the Name column of the port Enter a name for identification like Richard and press Enter 2 Leave the Admin column Enable value to make the port to be in operation or Disable to pause it 3 Select...

Страница 26: ...k Duplicate button the dialogue screen appears 1 Select Source Port for example Port 1 2 Select Target Port click All for select all for example Port 2 3 4 5 3 Select the port attributes you want to d...

Страница 27: ...retrieve packets from the local packet buffer fast enough to transmit them onto the network RX Good Frame Types RX Bytes Number of bytes received in good and bad frames RX frames Number of good and b...

Страница 28: ...try of Community String and IP Address is for authentication to login to the SNMP agent for configuration Moreover the community capacity can up to 3 sets and only by the way of specified IP address h...

Страница 29: ...name for authentication in the Community String field ex administrator 2 Enter the IP address in the IP address field you allow to access from ex 192 168 1 22 3 Enter a expiry time for this entry wil...

Страница 30: ...he switch support 2 VLAN type 802 1Q VLAN and Port Group VLAN 802 1Q VLAN Before enabling 802 1Q VLAN pay attention to w All ports are default to VLAN 1 and assigned PVID 1 w Though you can configure...

Страница 31: ...his screen is used to Add Remove member ports of a VLAN To add member port 1 Click the VLAN ID combo box and select a VLAN you want new ports to join in 2 Select ports press Shift Ctrl key for selecti...

Страница 32: ...will not allow until you change it 4 Automatically a port will join the VLAN of its PVID and if the VLAN does not exist system will create it To Enable Disable Ingress Filtering When one packet comes...

Страница 33: ...to make switches join leave multicast group and interacts switches to optimize the network performance by monitoring the IGMP packets and forward to the ports containing multicast hosts or switches T...

Страница 34: ...4 12 STA The Spanning Tree Algorithm STA outlined in IEEE 802 1D can avoid network looping but coexist with linking backup This feature permits STA aware switches interact with each other This can en...

Страница 35: ...to this bridge However it is only required to be unique Root Port The port number of the port which offers the lowest cost path from this bridge to the root bridge Max Age 6 40 sec The maximum age of...

Страница 36: ...A compliant network Priority 1 65535 Priority is a decisive key for selecting root device root port and designated port The smaller number the higher priority The device with the highest priority beco...

Страница 37: ...90 recommends that the default value of this parameter be in inverse proportion to the speed of the attached LAN Fast Forward The device omits from the 4 steps Blocking Listening Learning Forwarding t...

Страница 38: ...acket 5 1 Send 5 high priority packets then 1 low priority packet 6 1 Send 6 high priority packets then 1 low priority packet 7 1 Send 7 high priority packets then 1 low priority packet 4 14 Address T...

Страница 39: ...Static Address table To remove a static address 1 Click the static address in the MAC address table of the port 2 Click Remove button to remove it from MAC address table 4 15 Mirror Port mirror is us...

Страница 40: ...37...

Страница 41: ...d device s power are on or not 2 The connecting cable is good and with correct type 3 The cable is firmly seated in its connectors in the switch and in the associated device 4 The connecting device in...

Страница 42: ...BI_DB BI_DA 4 BI_DC BI_DD 5 BI_DC BI_DD 6 BI_DB BI_DA 7 BI_DD BI_DC 8 BI_DD BI_DC Implicit implementation of the crossover function within a twisted pair cable or at a wiring panel while not expressly...

Страница 43: ...40 A 3 RJ 45 cable pin assignment 21 3 6 1 2 3 6 21 3 6 EM WGSW2403...

Отзывы: