Hardware Installation

Before  you  proceed  with  the  installation,  it  is  necessary  that  you  have  enough 
information about WAP-6200.

1. Locate  an  optimum  location  and  use  the  provided  Mounting  kit  to  tie  the  WAP-

6200 to a pole.

Note

For  secured  reason,  while  install  the  CPE  AP,  please  be  aware  for 
the electric wires around, and tighten the pole. 
Without  tighten  the  CPE  AP,  the  pole  and  the  installed  site  is  with 
electric  wire  around,  there  could  be  danger  of  being  hurt  by  falling 
or lethal injury.

2. Strongly  suggest  using  SFTP  cable  (PLANET  offers  25-meter  SFTP  cable,  please 

contact  with  local  dealer  for  more  information.)  for  waterproof  and  avoiding 
thunder  stroke,  connect  the  RJ45  cable  connector  of  the  WAP-6200  to  the 
“P+DATA OUT” port of PoE Injector.

Note

Strongly suggest using SFTP cable, for better protection of the data 
wire.  25-meter  SFTP  cable  also  available  by  order,  the  part  no  is 
WL-SFTP-25. Please contact with local dealer for more information.

 RJ45 CABLE

 BACK COVER

 FRONT COVER

 CPE SET

 POLE 1”-~1.5”

 Mouting Kit

Содержание WAP-6200

Страница 1: ...802 11g Wireless LAN Outdoor CPE AP WAP 6200 Quick Installation Guide...

Страница 2: ...Table of Contents Package Content 3 Hardware Installation 4 Web Configuration 8 Further Configuration 8...

Страница 3: ...flat panel antenna and default 200mW output power make WAP 6200 a suitable CPE solution for widely open space applications such as WISPs campuses and airports Except for 64 128 bit WEP encryption WAP...

Страница 4: ...and the installed site is with electric wire around there could be danger of being hurt by falling or lethal injury 2 Strongly suggest using SFTP cable PLANET offers 25 meter SFTP cable please contact...

Страница 5: ...ing Category 3 or higher UTP or STP cable connect the DATA IN port of PoE Injector to a 10Mbps or 10 100Mbps Ethernet hub or switch and connect the PC on the same LAN for management Note To avoid thun...

Страница 6: ...ntal distance from a tower mast or antenna to the nearest power line should be at least twice the total length of the mast antenna combination This will ensure that the mast will not contact power if...

Страница 7: ...ve ground or to one or more approved grounding rods using 1 OAWG ground wire and corrosion resistant connectors Refer to the National Electrical Code for grounding details IF A PERSON COMES IN CONTACT...

Страница 8: ...254 into the Address Field of you web browser Before configuration please make sure your PC s IP address is under the same IP range with WAP 6200 such as 192 168 1 x 3 After enter the IP address and p...

Отзывы: