User’s Manual of MGSD-10080F
46
2.3 Cabling
10/100/1000Base-T and 100Base-FX / 1000Base-SX/LX
All 10/100/1000Base-T ports come with Auto-Negotiation capability. They automatically support 1000Base-T, 100Base-TX
and 10Base-T networks. Users only need to plug a working network device into one of the 10/100/1000Base-T ports, and
then turn on the
Managed Switch
. The port will automatically runs in 10Mbps, 20Mbps, 100Mbps or 200Mbps and
1000Mbps or 2000Mbps after the negotiation with the connected device.
The
Managed Switch
has eight SFP interfaces that support 100/1000Mbps dual speed mode (Optional multi-mode/
single-mode 100Base-FX/1000Base-SX/LX SFP module)
Cabling
Each 10/100/1000Base-T port uses RJ-45 sockets -- similar to phone jacks -- for connection of unshielded twisted-pair
cable (UTP). The IEEE 802.3/802.3u 802.3ab Fast/Gigabit Ethernet standard requires Category 5 UTP for 100Mbps
100Base-TX. 10Base-T networks can use Cat.3, 4, 5 or 1000Base-T use 5/5e/6 UTP (see table below). Maximum distance
is 100meters (328 feet). The 100Base-FX/1000Base-SX/LX SFP slot is used as LC connector with optional SFP module.
Please see table below and know more about the cable specifications.
Port Type
Cable Type
Connector
10Base-T
Cat 3, 4, 5, 2-pair
RJ-45
100Base-TX
Cat.5 UTP, 2-pair
RJ-45
1000Base-T
Cat.5/5e/6 UTP, 2-pair
RJ-45
100Base-FX
50 / 125µm or 62.5 / 125µm multi-mode 9 / 125µm single-mode LC (multi/single mode)
1000Base-SX/LX 50 / 125µm or 62.5 / 125µm multi-mode 9 / 125µm single-mode LC (multi/single mode)
Any Ethernet devices like hubs/PCs can be connected to the
Managed Switch
by using straight-through wires. The two
10/100/1000Mbps ports are auto-MDI/MDI-X, which can be used on straight-through or crossover cable.
Содержание MGSD-10080F
Страница 1: ...User s Manual of MGSD 10080F 1 ...
Страница 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Страница 173: ...User s Manual of MGSD 10080F 173 Figure 4 8 2 Multicast Flooding Figure 4 8 3 IGMP Snooping Multicast Stream Control ...
Страница 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Страница 358: ...User s Manual of MGSD 10080F 358 ...
Страница 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Страница 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Страница 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Страница 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...