User’s Manual of MGSD-10080F
141
1.
While
[PC-1]
transmit an
untagged
packet enters
Port-1
, the Managed Switch will tag it with a
VLAN Tag=2
.
[PC-2]
and
[PC-3]
will receive the packet through
Port-2
and
Port-3
.
2.
[PC-4],[PC-5] and [PC-6] received no packet.
3.
While the packet leaves
Port-2
, it will be stripped away it tag becoming an
untagged
packet.
4.
While the packet leaves
Port-3
, it will keep as a
tagged
packet with
VLAN Tag=2
.
Tagged packet entering VLAN 2
5.
While
[PC-3]
transmit
V
a
tagged
packet with
VLAN Tag=2
enters
Port-3
,
[PC-1]
and
[PC-2]
will receive the packet
through
Port-1
and
Port-2
.
6.
While the packet leaves
Port-1
and
Port-2
, it will be stripped away it tag becoming an
untagged
packet.
Untagged packet entering VLAN 3
1.
While
[PC-4]
transmits an
untagged
packet enters
Port-4
, the switch will tag it with a
VLAN Tag=3
.
[PC-5]
and
[PC-6]
will receive the packet through
Port-5
and
Port-6
.
2.
While the packet leaves
Port-5
, it will be stripped away it tag becoming an
untagged
packet.
3.
While the packet leaves
Port-6
, it will keep as a
tagged
packet with
VLAN Tag=3
.
For this example, VLAN Group 1 is set as default VLAN, but only focuses on VLAN 2 and VLAN 3
traffic flow.
Setup steps
1. Create VLAN Group
Set VLAN Group 1 = Default-VLAN with VID (VLAN ID) =1
Add two VLANs – VLAN 2 and VLAN 3
VLAN Group 2 with VID=
2
VLAN Group 3 with VID=
3
2. Assign VLAN Member :
VLAN 2 : Port-1,Port-2 and Port-3
VLAN 3 : Port-4, Port-5 and Port-6
VLAN 1 : All other ports – Port-7~Port-24
3. Remove VLAN Member for VLAN 1:
Remember to remove the Port 1 – Port 6 from VLAN 1 membership, since the Port 1 – Port 6 have to be assigned to
VLAN 2 and VLAN 3.
Содержание MGSD-10080F
Страница 1: ...User s Manual of MGSD 10080F 1 ...
Страница 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Страница 173: ...User s Manual of MGSD 10080F 173 Figure 4 8 2 Multicast Flooding Figure 4 8 3 IGMP Snooping Multicast Stream Control ...
Страница 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Страница 358: ...User s Manual of MGSD 10080F 358 ...
Страница 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Страница 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Страница 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Страница 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...