User’s Manual of MGSD-10080F
349
R-APS messages.
The period of the guard timer can be configured in 10 ms steps between 10 ms
and 2 seconds, with a default value of 500 ms
•
WTR Time
The Wait To Restore timing value to be used in revertive switching.
The period of the WTR time can be configured by the operator in 1 minute steps
between 5 and 12 minutes with a default value of 5 minutes.
•
Hold Off Time
The timing value to be used to make persistent check on Signal Fail before
switching.
The range of the hold off timer is 0 to 10 seconds in steps of 100 ms
•
Version
ERPS Protocol Version - v1 or v2
•
Revertive
In Revertive mode, after the conditions causing a protection switch has cleared,
the traffic channel is restored to the working transport entity, i.e., blocked on the
RPL.
In Non-Revertive mode, the traffic channel continues to use the RPL, if it is not
failed, after a protection switch condition has cleared.
•
VLAN Config
VLAN configuration of the Protection Group. Click on the "VLAN Config" link to
configure VLANs for this protection group.
PRL Configuration:
Object
Description
•
PRL Role
It can be either RPL owner or RPL Neighbour.
•
PRL Port
This allows to select the east port or west port as the RPL block.
•
Clear
If the owner has to be changed, then the clear check box allows to clear the RPL
owner for that ERPS ring.
Instance Command:
Object
Description
•
Command
Administrative command. A port can be administratively configured to be in either
manual switch or forced switch state.
•
Port
Port selection - Port0 or Port1 of the protection Group on which the command is
applied.
Instance State:
Object
Description
Содержание MGSD-10080F
Страница 1: ...User s Manual of MGSD 10080F 1 ...
Страница 43: ...User s Manual of MGSD 10080F 43 Figure 2 8 Wires DO0 and DO1 to Open Detector ...
Страница 173: ...User s Manual of MGSD 10080F 173 Figure 4 8 2 Multicast Flooding Figure 4 8 3 IGMP Snooping Multicast Stream Control ...
Страница 276: ...User s Manual of MGSD 10080F 276 Figure 4 11 15 Windows 2003 AD Server Setting Path ...
Страница 358: ...User s Manual of MGSD 10080F 358 ...
Страница 488: ...User s Manual of MGSD 10080F 488 Example Disable SMAC mode MGSD 10080F Aggr mode smac disable ...
Страница 554: ...User s Manual of MGSD 10080F 554 Activate the alternate firmware image Syntax Firmware Swap ...
Страница 603: ...User s Manual of MGSD 10080F 603 SMTP Test ...
Страница 616: ...User s Manual of MGSD 10080F 616 Syntax Show STP ...