2.1 Product Description 

The PLANET Gigabit Ethernet Switch is an 8-Port 10/100/1000Mbps Web Smart Gigabit Ethernet Switch with 
non-blocking wire-speed performance. With 16Gbps internal switching fabric, the Gigabit Ethernet Switch can handle 
extremely large amounts of data transmission in a secure topology linking to a backbone or high-power servers. The 
Gigabit Ethernet Switch could recognize up to 8K MAC Address table. The Gigabit Ethernet Switch offers wire-speed 
packet transfer performance without risk of packet loss. The high data throughput, it can provide the most convenient for 
user to upgrade their network to Gigabit environment. 

 

2.1.1 Product Overview 

PLANET Gigabit Ethernet Switch is a Web Smart Gigabit Ethernet Switch with 8 RJ-45 10/100/1000Mbps ports for 
high-speed network connectivity. The Gigabit Ethernet Switch can also automatically identify and determine the correct 
transmission speed and half/full duplex mode of the attached devices with its 8 ports.  The Gigabit port can handle large 
amounts of data transmission in a secure topology linking to a backbone or high-power servers.

 

The Gigabit Ethernet Switch also supports store-and-forward forwarding scheme to ensure low latency and high data 
integrity, eliminates unnecessary traffic and relieves congestion on critical network paths. With an intelligent address 
recognition algorithm, the Gigabit Ethernet Switch could recognize up to 8K different MAC address and enables filtering 
and forwarding at full wire speed.  

 

 

 

 

 

Содержание GDS-800S

Страница 1: ...User s Manual GSD 800S GSD 802S 8 Port Gigabit Web Smart Ethernet Switch GSD 802PS 8 Port Gigabit Web Smart PoE Switch...

Страница 2: ...we would appreciate your comments and suggestions FCC Warning This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These...

Страница 3: ...g the SFP transceiver 10 3 SWITCH MANAGEMENT 12 3 1 OVERVIEW 12 3 2 MANAGEMENT METHODS 12 3 2 1 Web Management 12 3 2 2 Login the Switch 13 4 CONFIGURATION 14 4 1 MAIN MENU 14 4 2 SYSTEM 16 4 2 1 Syst...

Страница 4: ...Factory Reset 62 4 12 3 Firmware Upgrade 63 4 12 4 Configuration Upload 64 4 12 5 Ping 66 4 12 6 Cable Diagnostics 67 4 12 7 Web Smart Function 69 4 13 STATUS 73 4 13 1 Port Statistics 73 4 13 2 LACP...

Страница 5: ...product in case there is a need to return it to us for repair How to Use This Manual This Web Smart Gigabit Ethernet Switch User Manual is structured as follows Section 2 Installation It explains the...

Страница 6: ...e z 9K Jumbo Frame support at all speed 10 100 1000 Mbps Layer 2 Switching z Support port based and 802 1q VLAN function up to 64 VLAN groups z 802 1w Rapid Spanning Tree protocol support z Link Aggre...

Страница 7: ...ull duplex Dimensions mm W x D x H 217 x 135 x 43 5 1U height 330 x 155 x 43 5 1U height Weight 1 1kg 1 2kg 1 8 kg Power Requirement 100 240V AC 50 60 Hz Power Consumption 13 2 Watts maximum 41 4 BTU...

Страница 8: ...02 3x IEEE 802 3af Ethernet Fast Ethernet Gigabit Ethernet Gigabit Ethernet 1000Base SX LX Tagged VLAN Rapid Spanning Tree Port Based Authentication Link Aggregation Control Protocol Full Duplex flow...

Страница 9: ...out risk of packet loss The high data throughput it can provide the most convenient for user to upgrade their network to Gigabit environment 2 1 1 Product Overview PLANET Gigabit Ethernet Switch is a...

Страница 10: ...el 2 1 3 LED Indicators LED of GSD 800S GSD 802S LED Color Function PWR Green Lights to indicate that the Switch is powered on 1000 LNK ACT Green Lights to indicate that the Switch is successfully con...

Страница 11: ...cessfully connecting to the network at 10 100Mbps Blinks to indicate the Switch is receiving or sending data Figure 2 5 PLANET GSD 802PS LED panel Notice To press and release the RESET button The Giga...

Страница 12: ...steps Step1 Attach the rubber feet to the recessed areas on the bottom of the Gigabit Ethernet Switch Step2 Place the Gigabit Ethernet Switch on a desktop or shelf near an AC power source Step3 Keep...

Страница 13: ...to each side of the Gigabit Ethernet Switch with supplied screws attached to the package Figure 2 8 shows how to attach brackets to one side of the Gigabit Ethernet Switch Figure 2 8 Attach brackets...

Страница 14: ...ode and multi mode SFP transceiver The following list of approved PLANET SFP transceivers is correct at the time of publication MGB SX SFP 1000Base SX SFP transceiver MGB LX SFP 1000Base LX SFP transc...

Страница 15: ...e fiber NICs or Media Converters set the Link mode to 1000 Force is needed Remove the transceiver module 1 Make sure there is no network activity by consult or check with the network administrator Or...

Страница 16: ...ities including System Port Configuration Port Mirroring Storm Control VLANs Rapid Spanning Tree Link Aggregation IGMP Snooping Quality of Service 802 1X Management POE Configuration GSD 802PS Only MA...

Страница 17: ...e manager PC should be set at 192 168 0 x where x is a number between 2 and 254 and the default subnet mask is 255 255 255 0 Use Internet Explorer 5 0 or above Web browser Enter IP address http 192 16...

Страница 18: ...be the same to GSD 800S 4 1 Main Menu After a successful login the main screen appears the main screen displays the Switch status The screen in Figure 4 1 appears Figure 4 1 Web Main screen As listed...

Страница 19: ...ng the packet level to classify the packets priority 802 1X Management Specify ports with network access control MAC Address Dynamic Address Table Static MAC Address Tools Reboot Factory Reset Firmwar...

Страница 20: ...the device H W Version The current hardware versions running on the device Active IP Address The current IP Address of the device The IP Address could be manual assigned or get via DHCP server Active...

Страница 21: ...appears Figure 4 3 Misc Configuration screen The page includes the following configurable data DHCP Enable Choose what the switch should do following power up transmit a DHCP request or manual settin...

Страница 22: ...tion where the trap to be sent SNMP Read Community Functions as a password and used to authenticate the access right of the device The Read Community is restricted to read only for all MIBs except the...

Страница 23: ...eader CRC and payload Draw the menu bar to select the mode Disable The default maximum frame size is 1518 4096 Kbytes Set the maximum frame size to 4096 Bytes 9600 Kbytes Set the maximum frame size to...

Страница 24: ...bled on Full Duplex mode or Backpressure is enabled on Half Duplex mode Disable No flow control or backpressure function on no matter Full Duplex or Half Duplex mode Port Description Can key in the de...

Страница 25: ...owing configurable data Destination Port Use this option to select the port for monitored traffic This is the port that your network analyzer would be connected to such as NAI Sniffer Pro or Ethereal...

Страница 26: ...to decide if the packet is dropped by the Switch or delivered IEEE 802 1Q VLANs IEEE 802 1Q tagged VLAN are implemented on the Switch 802 1Q VLAN require tagging which enables them to span the entire...

Страница 27: ...with the specify VLAN ID Once the Add button be pressed The page will be redirect to have the VLAN member assign page Modify To modify an existence VLAN Group adds new member ports or remove ports fr...

Страница 28: ...istence VLAN Group Refer to the following steps 1 To modify the members of an existence VLAN Group check the VLAN Group ID and press Modify button The ID VLAN Setup screen will pop out 2 To add remove...

Страница 29: ...D 802S GSD 802PS Figure 4 9 VLAN Group member modify and delete VLAN Group screen Notice Once the VLAN Group be deleted the Ports with the PVID set to this VLAN Group have to re configure the PVID Or...

Страница 30: ...ly be broadcast among other members of the same VLAN group Note all unselected ports are treated as belonging to the default system VLAN If port based VLAN are enabled then VLAN tagging feature is ign...

Страница 31: ...ived on this port are accepted and assigned the value of the Port VLAN ID for this port Tagged only untagged frames or priority tagged frames received on this port are discarded With either option VLA...

Страница 32: ...rt 3 VLAN Group 3 3 Port 4 Port 5 Port 6 Table 4 1 VLAN and Port Configuration The scenario described as follow Untagged packet entering VALN 2 1 While PC 1 transmit an untagged packet enters Port 1 t...

Страница 33: ...ed packet 3 While the packet leaves Port 6 it will keep as a tagged packet with VLAN Tag 3 Notice At this example VLAN Group 1 just set as default VLAN but only focus on VLAN 2 and VLAN 3 traffic flow...

Страница 34: ...Port 6 from VLAN 1 membership since the Port 1 Port 6 had been assigned to VLAN 2 and VLAN 3 Figure 4 14 Remove specify ports from VLAN 1 member Notice It s import to remove the VLAN members from VLAN...

Страница 35: ...port Port 1 Port 2 and Port 3 PVID 2 Port 4 Port 5 and Port 6 PVID 3 Port 7 Port 8 PVID 1 4 Enable VLAN Tag for specific ports Link Type Port 3 VLAN 2 and Port 6 VLAN 3 The Per Port VLAN configuration...

Страница 36: ...all need to access with the same server The screen in Figure 4 16 appear This section will show you how to configure the port for the server that could be accessed by both VLAN 2 and VLAN 3 Figure 4 1...

Страница 37: ...as a Public Area that overlapping with both VLAN 2 members and VLAN 3 members Figure 4 18 VLAN 1 The public area member assign 4 Setup Port 7 with PVID 1 at VLAN per Port Configuration page The scree...

Страница 38: ...tches within the same VLAN group The screen in Figure 20 appears Figure 4 20 802 1Q Trunking with other VLAN aware device About the VLAN ports connect to the hosts please refer to 4 5 3 1 and 4 5 3 2...

Страница 39: ...SD 802S GSD 802PS Figure 4 22 Add VLAN Trunk port to each VLAN 3 Repeat Step 1 and 2 setup the VLAN Trunk port at the partner switch 4 To add more VLANs to join the VLAN trunk repeat Step 2 to assign...

Страница 40: ...ing tree without creating forwarding loops The devices support the following Spanning Tree protocols Compatiable Spanning Tree Protocol STP Provides a single path between end stations avoiding and eli...

Страница 41: ...conds a root bridge waits between configuration messages Value Range 1 10 The default is 2 seconds Max Age Specifies the device Maximum Age Time The Maximum Age Time indicates the amount of time in se...

Страница 42: ...g RSTP properties to individual ports The screen in Figure 4 25 appears Figure 4 25 RSTP Port Configuration The page includes the following fields Port Indicate port 1 to port 24 Edge Indicates whethe...

Страница 43: ...ure 1 Click Status RSTP Status 2 The RSTP VLAN Bridge Overview and RSTP Port Status screen is displayed as in Figure 4 26 Figure 4 26 RSTP Status screen RSTP VLAN Bridge Overview The information of th...

Страница 44: ...ears Figure 4 28 RSTP Status screen The page includes the following fields Port Group Port or Link Aggregation group on which Rapid STP is enabled VLAN Id Port or Link Aggregation interfaces associate...

Страница 45: ...MAC addresses Learning The port is currently in the learning mode The port cannot forward traffic however it can learn new MAC addresses Forwarding The port is currently in the forwarding mode The po...

Страница 46: ...evant links Aggregated Links are treated by the system as a single logical port Specifically the Aggregated Link has similar port attributes to a non aggregated port including auto negotiation speed D...

Страница 47: ...switch model the maximum number of ports are as follow A port can be assigned to only one Trunk Group 4 7 2 LACP Link Aggregation Control Protocol LACP LACP LAG negotiate Aggregated Port links with ot...

Страница 48: ...value will also be the identify ID to the linked LACP switch The default setting is Auto Notice When using a port link aggregation note that The ports that can be assigned to the same link aggregation...

Страница 49: ...n Overview Table The LACP Aggregation Overview Table lists the active LACP ports and mapped Group It also indicates the Partner Port number of the other LACP aware switches The screen in Figure 4 32 a...

Страница 50: ...s The page includes the following fields Port Indicate port 1 to port 8 Protocol Active Indicate the LCAP protocol is enable or not on the port Yes LACP is enabled and active on the port No LACP is no...

Страница 51: ...value Router Ports The Router Ports check box fields for attaching ports to a device that is attached to a neighboring Multicast router switch Once IGMP Snooping is enabled Multicast packets are forwa...

Страница 52: ...outer can check using IGMP to see if there is at least one member of a multicast group on a given subnet work If there are no members on a sub network packets will not be forwarded to that sub network...

Страница 53: ...enabled but might be at the initiation status or there re already other Querier exist Queries transmitted Statistics of IGMP Query packets transmitted from the VLAN Only the IGMP Querying Enabled be...

Страница 54: ...ssigns ports to a specific Multicast service address group To open Multicast Group Tables screen perform the folling 1 Click Status Multicast Group Table 2 The Multicast Group Table screen is displaye...

Страница 55: ...throughput for multimedia applications such as video conferencing or voice over IP by minimizing delay and jitter Improve performance for specific types of traffic and preserve performance as the amou...

Страница 56: ...gs allow customization of packet priority in order to facilitate delivery of data traffic that might be affected by latency problems The IEEE 802 1p Priority specification uses 8 priority levels to cl...

Страница 57: ...able All Low Priority mapping all 802 1p tagged packets to Queue 0 All Normal Priority mapping all 802 1p tagged packets to Queue 1 All Medium Priority mapping all 802 1p tagged packets to Queue 2 All...

Страница 58: ...llows customization of DSCP to Traffic classifiers Total 5 selections for the Prioritize Traffic Custom Manual mapping the DSCP to the 4 level queues Setup at the next table All Low Priority mapping a...

Страница 59: ...would have to be authenticated by RADIUS server If the client is authorized Switch would be notified to open up a communication port to be used for the client There are 2 Extensive Authentication Prot...

Страница 60: ...length This section is to control the access of the switch includes the user access and management control The 802 1X Management page contains links to the following topics RADIUS Server Configuration...

Страница 61: ...ver being added RADIUS UDP Port The UDP port used by this server The valid range is 0 65535 The default UDP Port No is 1812 RADIUS Secret Indicates if the shared secret for this server has been config...

Страница 62: ...ts the options for control mode The control mode is only set if the link status of the port is link up The options are Auto The authenticator PAE sets the controlled port mode to reflect the outcome o...

Страница 63: ...d This select field allows the user to enable or disable reauthentication of the supplicant for the specified port If Enabled be checked reauthentication will occur Otherwise reauthentication will not...

Страница 64: ...pdated within a given time You specify that time by entering a value for the Address Ageing Timeout You may enter any number of seconds between 0 and 65535 IEEE 802 1D recommends a default of 300 seco...

Страница 65: ...n The configable filelds includes the following items VID The VLAN ID attached to the MAC Address Ports Specifies the port numbers for which the table is queried MAC Address Input the MAC address entr...

Страница 66: ...reset the Gigabit Ethernet Switch back to the factory default mode Be aware that the entire configuration will be reset expect the IP address of the Gigabit Ethernet Switch Once the Factory Reset item...

Страница 67: ...he firmware then click Upload the Software Upload Progress would show the file upload status Figure 4 51 Firmware Upgrade screen 5 Once the software be loaded to the system successfully The following...

Страница 68: ...e existed configuration file to the Switch The configuration file had been saved at the local machine already Configuration Download Download the current configuration file of the switch to the local...

Страница 69: ...status 3 After down the main screen appears Transfer Completed Configuration Download 1 Press the Download button to save the current configuration in manager workstation The following screens in Fig...

Страница 70: ...rable data Figure 4 57 Ping function screen The Ping Parameters includes the following fields Target IP Address Enter the IP address of the station you want the switch to ping The initial value is bla...

Страница 71: ...100BASE TX or 10BASE T the Cable Diagnostics cause the link to drop while the diagnostics are running After the diagnostics are finished the link is reestablished And the following functions are avail...

Страница 72: ...short has occurred in the cable With 10 100BASE link the status of Pair C and Pair D will be Short Abnormal termination An improper termination be detected Proper termination of Cat5 cable requires a...

Страница 73: ...ears Figure 4 60 Web Smart Function Web Page screen The available options are shown as below 1 PC 2 PC VoIP 3 Switch 4 Router 5 AP 6 Server 7 Printer 8 Guest 9 Other The screen in Figure 4 61 appears...

Страница 74: ...D 800S GSD 802S GSD 802PS 3 After setup completed press Apply to save current configuration the screen in Figure 4 62 appears Figure 4 61 Web Smart Function Web Page screen Figure 4 62 Web Smart Funct...

Страница 75: ...s below 1 Choose a device and check Apply for all ports from options of Select a port function the screen in Figure 4 63appears 2 Check any port then all port will be select the screen in Figure 4 64...

Страница 76: ...User s Manual of GSD 800S GSD 802S GSD 802PS Figure 4 64 Web Smart Function Web Page screen Figure 4 65 Web Smart Function Web Page screen...

Страница 77: ...gure 4 66 Port Statistics Overview screen The page includes the following fields Port The Port number Receive Packets Number of packets received on the port Include the Unicast packets Receive Octets...

Страница 78: ...for more detail 4 13 4 IGMP Snooping Status The IGMP Snooping page display the current IGMP Status and the statistics of received Query report packets Please refer to Chapter 4 8 2 at page 53 for more...

Страница 79: ...User s Manual of GSD 800S GSD 802S GSD 802PS Figure 4 68 Login screen...

Страница 80: ...sumption is monitored by measuring voltage and current The input power consumption is equal to the system s aggregated power consumption The power management concept allows all ports to be active and...

Страница 81: ...p side the orange port icon shows that the port is connected to PDs with PoE output For more detail status about the usage of each PoE port the Delivering Power and Current mA columns shows the curren...

Страница 82: ...then this packet will be filtered There by increasing the network throughput and availability 5 4 Store and Forward Store and Forward is one type of packet forwarding techniques A Store and Forward E...

Страница 83: ...nformation received from IGMP is then used to determine if multicast packets should be forwarded to a given sub network or not The router can check using IGMP to see if there is at least one member of...

Страница 84: ...roup members on the network The Time to Live TTL field of query messages is set to 1 so that the queries will not be forwarded to other sub networks IGMP version 2 introduces some enhancements such as...

Страница 85: ...Ethernet Switch is set to full duplex and the partner is set to half duplex then the performance will be poor 100Base TX port link LED is lit but the traffic is irregular Solution Check that the atta...

Страница 86: ...BI_DC Implicit implementation of the crossover function within a twisted pair cable or at a wiring panel while not expressly forbidden is beyond the scope of this standard A 2 10 100Mbps 10 100Base T...

Страница 87: ...cable and each wire is color coded The following shows the pin allocation and color of straight cable and crossover cable connection Figure A 1 Straight Through and Crossover Cable Please make sure yo...