manualshive.com logo in svg
background image

 

 

 

 

 

User’s Manual of UPOE-800G / UPOE-1600G

 

 

  

 

 

Содержание UPOE-1600G

Страница 1: ...User s Manual of UPOE 800G UPOE 1600G 1 ...

Страница 2: ...es These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the Instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is l...

Страница 3: ...B 19 2 2 1 Desktop Installation 19 2 2 2 Rack Mounting 20 2 2 3 Network Application Installation 22 2 2 4 Power over Ethernet Powered Device 23 3 Management 24 3 1 OVERVIEW 24 3 2 REQUIREMENTS 24 3 3 MANAGEMENT METHOD 25 3 3 1 Web Management 25 3 3 2 PLANET Smart Discovery Utility 26 4 WEB CONFIGURATION 28 4 1 MAIN MENU 28 4 2 WEB PANEL 29 4 3 SYSTEM 29 4 3 1 System Information 30 4 3 2 IP Configu...

Страница 4: ...le 48 4 5 3 PoE Alive Check Configuration 52 4 5 4 PoE Status 54 5 Power Over Ethernet Overview 55 6 The PoE Provision Process 57 6 1 LINE DETECTION 57 6 2 CLASSIFICATION 57 6 3 START UP 58 6 4 OPERATION 58 6 5 POWER DISCONNECTION SCENARIOS 58 APPENDIX A 60 A 1 MDI SETTINGS 60 A 2 POWER DEVICE CLASSIFICATION VALUES 60 A 3 DATA OUT POE INJECTOR RJ45 PORT PIN ASSIGNMENTS 61 ...

Страница 5: ...ltra PoE Managed Injector Hub and carefully unpack it The box should contain the following items The UPOE 800G or UPOE 1600G x 1 Quick Installation Guide x 1 Power Cord x 1 Rubber Feet x 4 19 Rack mounting Brackets x 2 If any of these are missing or damaged please contact your dealer immediately if possible retain the carton including the original packing material and use them again to repack the ...

Страница 6: ...mall businesses and enterprises Quick and Easy PoE Network Deployment The Ultra PoE Managed Injector Hub is installed between a regular Ethernet Switch and the PDs There are totally 16 32 RJ45 STP ports on the front panel of the Ultra PoE Managed Injector Hub of which the 8 16 ports are on the lower stack functioned as Data input while the other 8 16 ports are on the upper stack functioned as PoE ...

Страница 7: ... point of sale POS and information kiosks Remote digital signage display Friendly Web Management Interface To efficiently manage the powered devices the Ultra PoE Managed Injector Hub provides simple Web management interface in which administrators can control the system and PoE functions for powered devices It can automatically detect the power status of each port and show messages on its Web man...

Страница 8: ...ime via ping action through the uplinked Ethernet switch Once the PD stops working and responding the Ultra PoE Managed Injector Hub will recycle the PoE port power and bring the PD back to work It also will greatly enhance the network reliability in that the PoE port will reset the PD power thus reducing administrator s management burden PoE Schedule for Energy Saving Under the trend of energy sa...

Страница 9: ...f various powered devices consuming stable PoE power the Ultra PoE Managed Injector Hub provides three different PoE power output modes for selection 60W UPOE PoE Power Output Mode Pins 1 2 3 6 Pins 4 5 7 8 30W End span PoE Power Output Mode Pins 1 2 3 6 30W Mid span PoE Power Output Mode Pins 4 5 7 8 9 ...

Страница 10: ... front panel of the UPOE 800G has four green LEDs indicating 100W 200W 300W and 400W of PoE power usage The front panel of the UPOE 1600G also has four green LEDs indicating 150W 300W 450W and 600W of PoE power usage PoE Usage Monitoring Via the power usage chart in the web management interface the Ultra PoE Managed Injector Hub enables the administrator to monitor the status of the power usage of...

Страница 11: ...l is structured as follows Section 2 Installation It explains the functions of Ultra PoE Managed Injector Hub and how to physically install the Ultra PoE Managed Injector Hub Section 3 Management It contains information about the software function of the Ultra PoE Managed Injector Hub Section 4 Web Configuration The section explains how to manage the Ultra PoE Managed Injector Hub through Web inte...

Страница 12: ...ower over Ethernet end span mid span PSE Up to 60 watts of power on 4 pair UTP Backward compatible with IEEE 802 3at af PD device 54V DC 60 watt PoE power output at maximum on each port 400 watt PoE budget UPOE 800G 52V DC 60 watt PoE power output at maximum on each port 600 watt PoE budget UPOE 1600G Auto detection of IEEE 802 3at af PoE equipment and device to avoid possible damage by incorrect ...

Страница 13: ...lity automatically finds PLANET devices on the network SNMP trap for alarm notification of events System log remote syslog Hardware 19 inch rack mountable 1U height Reset button for resetting to default setting and system reboot LED indicators for PoE ready and PoE activity LED indicators for power alert and fan alert LED indicators for PoE power usage status watts FCC Part 15 Class A CE ...

Страница 14: ...00 watts max 2729BTU Ventilation Fan x 3 Fan x 3 Dimensions W x D x H 440 x 300 x 44 5 mm 1U height 440 x 300 x 44 5 mm 1U height Enclosure Metal Metal Weight 4 2kg 4 8kg Power over Ethernet PoE Standard IEEE 802 3af Power over Ethernet IEEE 802 3at Power over Ethernet Plus 4 pair Ultra PoE PoE Power Supply Type End span Mid span UPoE Ultra PoE Power Pin Assignment Pair 1 end span 1 2 3 6 Pair 2 m...

Страница 15: ...vents Standards Conformance Regulatory Compliance FCC Part 15 Class A CE Standards Compliance IEEE 802 3 10BASE T Ethernet IEEE 802 3u 100BASE TX Fast Ethernet IEEE 802 3ab 1000BASE T Gigabit Ethernet IEEE 802 3at Power over Ethernet Plus IEEE 802 3af Power over Ethernet RFC 768 UDP RFC 791 IP RFC 2068 HTTP RFC 1157 SNMP v1 RFC 1902 SNMP v2c RFC 5424 Syslog Network Cable 10BASE T 4 pair UTP Cat5 u...

Страница 16: ...tion The section describes the hardware of the Ultra PoE Managed Injector Hub and gives a physical and functional overview 2 1 1 Injector Front Panel The unit front panel provides a simple interface monitoring the Ultra PoE Managed Injector Hub Figures 2 1 1 and 2 1 2 show the front panels of the Ultra PoE Managed Injector Hubs Front Panel of UPOE 800G Figure 2 1 1 UPOE 800G Front Panel Front Pane...

Страница 17: ...dministrator to monitor and troubleshoot when needed UPOE 800G System LED Color Function SYS Power Green Lights to indicate power on PoE Fail Red Lights to indicate PoE module failure FAN1 Fail Red Lights to indicate FAN1 stops FAN2 Fail Red Lights to indicate FAN2 stops 1000 Green Lights to indicate management port is working on 1000Mbps Ethernet speed 10 100 Orange Lights to indicate management ...

Страница 18: ... 60W PoE in Use Green Lights to indicate that the port is in use and supplying 52V DC power 802 3at af PoE in Use Orange Lights to indicate that the port is in use and supplying 52V DC power 2 1 3 Injector Rear Panel The rear panel of the Ultra PoE Managed Injector Hub indicates an AC inlet power socket which accepts input power from 100 to 240V AC 50 60Hz Figures 2 1 4 shows the rear panel of the...

Страница 19: ...nding objects Figure 2 2 1 Desktop Installation of the Ultra PoE Managed Injector Hub When choosing a location please keep in mind the environmental restrictions discussed in Chapter 1 Section 5 under Specifications Step 4 Connect your Ultra PoE Managed Injector Hub to network 60W 802 3at 802 3af powered devices PD and Switch A Connect one end of a standard network cable to the upper stack 10 100 ...

Страница 20: ...h the front panel positioned towards your front side Step 2 Attach a rack mount bracket to each side of the Ultra PoE Managed Injector Hub with supplied screws attached to the package Figure 2 2 2 shows how to attach brackets to one side of the Ultra PoE Managed Injector Hub Figure 2 2 2 Brackets attaching to the Ultra PoE Managed Injector Hub You must use the screws supplied with the mounting bra...

Страница 21: ...1600G Figure 2 2 3 Mounting the Ultra PoE Managed Injector Hub in a Rack Step 6 Proceed with steps 4 and 5 of session 2 2 1 Desktop Installation to connect the network cabling and supply power to your Ultra PoE Managed Injector Hub 21 ...

Страница 22: ... complete the following steps Step 1 Power on the Ultra PoE Managed Injector Hub and connect the RJ45 cable from the Data port to the Ethernet switch port Step 2 Connect the RJ45 cable from the Data Power ports to the PDs such as VoIP phone and IP camera Step 3 Check the link status on both PD and Ethernet switch Once the Injector starts to deliver 52V 54V power over RJ45 cables to PDs the PoE in ...

Страница 23: ...oE Splitter PoE Splitter splits the PoE DC over the Ethernet cable into 5 12 19 24V DC power output It frees the device deployment from restrictions due to power outlet locations which eliminate the costs for additional AC wiring and reduces the installation time 30 60 watts High Power Speed Dome This state of the art design is considerable to fit in various network environments like traffic cente...

Страница 24: ...ndard network UTP cables with RJ45 connectors Workstations running Windows XP 2003 Vista 7 8 2008 10 MAC OS X or later Linux UNIX or other platforms are compatible with TCP IP protocols Workstations are installed with Ethernet NIC Network Interface Card Ethernet Port Connection Network cables Use standard network UTP cables with RJ45 connectors The above PC is installed with Web browser and JAVA r...

Страница 25: ...IP address is set to factory default then your manager PC should be set to 192 168 0 x where x is a number between 1 and 254 except 100 with a subnet mask of 255 255 255 0 1 Use Internet Explorer 8 0 or above Web browser Enter IP address http 192 168 0 100 to access the Web interface Figure 3 1 1 IP Management Diagram 2 When the following login screen appears please enter the default username admi...

Страница 26: ...your Ethernet environment Planet Smart Discovery Utility from user s manual CD ROM is an ideal solution The following installation instructions guide you to running Planet Smart Discovery Utility Deposit Planet Smart Discovery Utility in administrator PC Run this utility and the following screen appears Figure 3 1 3 Planet Smart Discovery Utility Screen If there are two LAN cards or above in the s...

Страница 27: ... Device Update Multi or Update All button to take effect The definitions of the 3 buttons above are shown below Update Device Use current setting on one single device Update Multi Use current setting on multi devices Update All Use current setting on whole devices in the list The same functions mentioned above also can be found in Option tools bar By clicking the Control Packet Force Broadcast fun...

Страница 28: ... web screen is based on the UPOE 1600G The display of the UPOE 800G is the same as that of the UPOE 1600G 4 1 Main Menu After a successful login the main screen appears The main screen as shown in Figure 4 1 1 displays the product name the function menu and the main information in the center Figure 4 1 1 Web Main Menu screen The descriptions of the four items are as follows Object Description Prov...

Страница 29: ...ure 4 2 2 is shown below Figure 4 2 2 System Function Menu The page includes the following information Object Description Display the MAC address Software Version Hardware Version IP Address Subnet Mask Gateway and Description Explained in section 4 3 1 System Information Allow to change the IP subnet address of Ultra PoE Managed Injector Hub Explained in section 4 3 2 IP Configuration Allow to se...

Страница 30: ... Displays the Ultra PoE Managed Injector Hub model name MAC Address Displays the MAC address of Ultra PoE Managed Injector Hub Software Version Displays the current firmware version of Ultra PoE Managed Injector Hub Build Time Displays the firmware build time Hardware Version Displays the hardware version of Ultra PoE Managed Injector Hub Attain IP Protocol Displays the currently attained IP proto...

Страница 31: ...s of Ultra PoE Managed Injector Hub Subnet Mask Allows to input new Subnet Mask Address of Ultra PoE Managed Injector Hub Default Gateway Allows to input new Default Gateway Address of Ultra PoE Managed Injector Hub Apply Press this button to take effect Reset Press this button to reset IP Configuration to default mode Table 4 3 2 Descriptions of the IP Configuration Objects Screen If Ultra PoE Ma...

Страница 32: ...ion of Ultra PoE Managed Injector Hub Current Time Enable NTP Client Update Allow disable or enable time update from NTP server of Ultra PoE Managed Injector Hub Allow select the time zone according to current location of Ultra PoE Managed Injector Hub Time Zone Select Allow choose one list NTP server or assign one NTP server IP address manually for Ultra PoE Managed Injector Hub NTP Server Press ...

Страница 33: ...Injector Hub User Name Allows to input current Password of Ultra PoE Managed Injector Hub Old Password Allows to input new Password of Ultra PoE Managed Injector Hub New Password Allows to input new Password again for confirmation of Ultra PoE Managed Injector Hub Confirmed Password Press this button to take effect Apply Press this button to reset password setting to default mode Reset Table 4 3 4...

Страница 34: ...ts in your PC The screen in Figure 4 3 6 appears Figure 4 3 6 Firmware Upgrade Web Page Screen Press Upgrade to start the firmware upgrade process as the screen in Figure 4 3 7 appears Figure 4 3 7 Firmware Upgrade Web Page Screen 1 The firmware upgrade process needs 97 seconds to complete and system will reboot automatically After the Ultra PoE Managed Injector Hub power on is completed the lates...

Страница 35: ...tion Allow to save system configuration to a file and download to manager workstation Save Settings to File Allow to restore system configuration to Ultra PoE Managed Injector Hub Load Settings form File Allow to specify the system configuration file locate path Browse Upload system configuration file to Ultra PoE Managed Injector Hub Upload Table 4 3 5 Descriptions of the Configuration Setting Ob...

Страница 36: ...ave Screen Configuration Upload Click the Browse button of the Configuration Setting Web page and the system would pop up the file selection screen to choose saved configuration The screen in Figure 4 3 11 appears Figure 4 3 11 Windows File Selection Screen 36 ...

Страница 37: ...ears Figure 4 3 12 Configuration Upload Finished Screen When configuration has been uploaded please re login the system Figure 4 3 13 System Login Screen 4 3 7 Factory Default This section describes resetting the Ultra PoE Managed Injector Hub to factory default mode the screen appears in Figure 4 3 14 Figure 4 3 14 Factory Default Web Page Screen 37 ...

Страница 38: ... to continue the factory default process The screen appears in Figure 4 3 15 Figure 4 3 15 Factory Default Web Page Screen Then the reboot screen appears in Figure 4 3 16 and please wait for 60 seconds for rebooting the Ultra PoE Managed Injector Hub Figure 4 3 16 Factory Default Web Page Screen After 60 seconds the main menu Web page screen appears in Figure 4 3 17 Figure 4 3 17 Main Web Page Scr...

Страница 39: ...iption Disable or enable the system log function of Ultra PoE Managed Injector Hub Enable Log Allow to send system log to remote log server Enable Remote Log Allow to set IP address of remote log server Log Server IP Address Press this button to take effect Apply Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Auto Refresh Press this button to refresh curr...

Страница 40: ...ctor Hub as the screen in Figure 4 3 19 appears Figure 4 3 19 System Reboot Web Page Screen Press the Reboot button to reboot the Ultra PoE Managed Injector Hub as the screen in Figure 4 3 20 appears Figure 4 3 20 System Reboot Web Page Screen Wait for 60 seconds for completing the reboot process of Ultra PoE Managed Injector Hub 40 ...

Страница 41: ...ure 4 3 21 appears Figure 4 3 21 Logout Web Page Screen Press the Logout button and then the popup window with re login request appears as the screen in Figure 4 3 22 appears Figure 4 3 22 Logout Web Page Screen Please input the password for entering into Web main menu screen of Ultra PoE Managed Injector Hub as the screen in Figure 4 3 23 appears ...

Страница 42: ...User s Manual of UPOE 800G UPOE 1600G Figure 4 3 23 Main Web Page Screen 42 ...

Страница 43: ...NMP Management and SNMP Trap as shown in Figure 4 4 1 Figure 4 4 1 SNMP Function Menu The page includes the following information Object Description Allow to enable or disable SNMP Agent and Trap Receiver function It provides user to manage system information and SNMP Trap destination IP address Explained in section 4 4 1 SNMP Management Table 4 4 1 Descriptions of the System Log Objects Screen 4 ...

Страница 44: ...ut characters for System Name of Ultra PoE Managed Injector Hub The maximum length is 30 characters System Location Allows to input characters for System Location of Ultra PoE Managed Injector Hub The maximum length is 30 characters Contact Allows to input characters for contact of Ultra PoE Managed Injector Hub The maximum length is 30 characters Description Allows to input characters for descrip...

Страница 45: ... additional ports as long as the aggregated power of the system is lower than the power level at which additional PDs cannot be connected When this value is exceeded ports will be deactivated according to user defined priorities The power budget is managed according to the following user definable parameters maximum available power ports priority and maximum allowable power per port The Power over...

Страница 46: ...where PoE power is delivered as system default setting is in this mode Allocation Users allow to assign how much PoE power to each port and the system will reserve PoE power to PD Prevent system from being too hot that may cause damage When PoE unit temperature rises over the temperature threshold value PoE power budget will be reduced Over Temperature Protection Displays the current operating tem...

Страница 47: ...ir 1 in both T568A and T568B form one side of the DC supply and pins 7 8 pair 4 in both T568A and T568B provide the return Priority The Priority represents PoE ports priority There are three levels of power priority named Low High and Critical The priority is used in case the total power consumption is over the total power budget In this case the port with the lowest priority will be turned off an...

Страница 48: ...or disable PoE power feeding for PoE ports during specified time intervals and it is a powerful function to help SMBs or enterprises save power and money Scheduled Power Recycling The Ultra PoE Managed Injector Hub allows each of the connected PoE IP cameras to reboot at a specified time each week Therefore it will reduce the chance of IP camera crash resulting from buffer overflow 48 ...

Страница 49: ...chedule for enable PoE Schedule function of each port Schedule Indicates the scheduled profile mode Possible profiles are Profile1 Profile2 Profile3 Profile4 This function available when choose schedule on each port button Saves the current configuration button Refreshes the Web page and the current configuration if user doesn t save it Check this box to refresh the page automatically Automatic re...

Страница 50: ... 4 PoE Schedule Web Page Screen The page includes the following information Object Description Profile Set the schedule profile mode Possible profiles are Profile1 Profile2 Profile3 Profile4 Delete Check to delete the entry Week Day Allows user to set week day for defining PoE function by enabling it on the day Sun Sunday Mon Monday Tue Tuesday Wed Wednesday Thu Thursday Fri Friday Sat Saturday ...

Страница 51: ...eboot Only function This function offers administrator to reboot PoE device at an indicated time if administrator has this kind of requirement Reboot Enable Allows user to reboot PoE function by PoE reboot schedule Please note that if administrator enables this function PoE schedule will not set time to profile This function is just for PoE port to reset at an indicated time Reboot Only Allows use...

Страница 52: ...ction Once the PD stops working and without response the Ultra PoE Managed Injector Hub are going to restart PoE port power and bring the PD back to work It will greatly enhance the reliability and reduces administrator management burden This page provides you with how to configure PD Alive Check as the screen in Figure 4 5 5 appears Figure 4 5 5 PD Alive Check Configuration Screenshot ...

Страница 53: ... be reset Action Allows user to set which action will be apply if the PD is without any response The Ultra PoE Managed Injector Hub offers 3 actions as follows PD Reboot It means system will reset the PoE port that is connected to the PD PD Reboot Alarm It means system will reset the PoE port and issue an alarm message via Syslog Alarm It means system will issue an alarm message via Syslog Reboot ...

Страница 54: ...llowing fields Object Description Displays per port status Port Number Displays per port PoE usage Watt Indicates the end span PoE operation mode of that port Indicates the mid span PoE operation mode of that port Indicates the ultra PoE operation mode of that port Buttons Check this box to refresh the page automatically Automatic refresh occurs every 3 seconds Refreshes the Web page and the curre...

Страница 55: ...itch and the powered device Mid Span taps the unused wire pairs 4 5 and 7 8 to carry power the other four are for data transmission End Span End Span device is directly connected with power device End Span could also tap the wire 1 2 and 3 6 PoE system architecture The specification of PoE typically requires two devices the Powered Source Equipment PSE and the Powered Device PD The PSE is either a...

Страница 56: ... 2 Power Supplied over the Data Pins When to install PoE Consider the following scenarios You re planning to install the latest VoIP Phone system to minimize cabling building costs when your company moves into new office next month The company staff has been clamoring for a wireless access point in the picnic area behind the building so they can work on their laptops through lunch but the cost of ...

Страница 57: ...as the correct signature resistance of 15 33 kΩ 2 7 10 0 1 8 10 0 Classification Measure which power level class the resistor indicates 14 5 20 5 12 5 25 5 Startup Where the powered device will start up 42 37 2 38 Normal operation Supply power to device 44 57 50 57 25 0 60 0 6 1 Line Detection Before power is applied safety dictates that it must first be ensured that a valid PD is connected to the...

Страница 58: ...ile limiting current drain during this period to protect the cabling infrastructure Immediate voltage drop is avoided to prevent shutdown due to random fluctuations 6 5 Power Disconnection Scenarios The IEEE 802 3af IEEE 802 3at standard requires that devices powered over Ethernet be disconnected safely i e power needs to be shut down within a short period of time following disconnection of a PD f...

Страница 59: ...o the 52 VDC operating voltage The returned AC signal amplitude is monitored by the PSE at the port terminals During normal operation the PD s relatively low impedance lowers the returned AC signal while a sudden disconnection of this PD will cause a surge to the full AC signal level and will indicate PD disconnection ...

Страница 60: ...ive 2 Vport Negative 3 Vport Positive 4 Vport Positive 5 Vport Positive 6 Vport Positive 7 Vport Negative 8 Vport Negative Table 1 Alternative Table Delivering power through an RJ45 connector s center tap Phantom Feeding guarantees that bi directional data flow is maintained regardless of a module s power status A 2 Power Device Classification Values Class PD Current Classification Period mA PD Po...

Страница 61: ...af 802 3at Standard PD with PoE Mid span PD Pin out of Cisco non 802 3af standard PD Pin out of POE Mid span PIN NO SIGNAL 1 RX 2 RX 3 TX 4 VCC 5 VCC 6 TX 7 VCC 8 VCC PIN NO SIGNAL 1 RX 2 RX 3 TX 4 VCC 5 VCC 6 TX 7 VCC 8 VCC Before you power PD please check whether the RJ45 connector pin assignment follows IEEE 802 3af IEEE 802 3at standard otherwise you may need to change one of the RJ45 connecto...

Отзывы: