<10-2000>
Guard time in ms
Default:
500
Usage Guide:
To configure the
Guard Time
for
ERPS.
Example:
To configure the
Guard Time
(178 ms) for
ERPS
(Profile 1)
Switch# configure terminal
Switch (config)#
erps 1 guard 178
4.2.41 erps <1-64> holdoff
Command:
erps <1-64> holdoff <
0-10000>
<1-64>
ERPS group number
<
0-10000>
Holdoff time in ms
Default:
0
Usage Guide:
To configure the
Hold Off Time
for
ERPS
Example:
To configure the
Hold Off Time
(178 ms) for
ERPS
(Profile 1)
Switch# configure terminal
Switch (config)#
erps 1 holdoff 900
4.2.42 erps <1-64> major
Command:
erps <1-64> major port0 interface {10GigabitEthernet, GigabitEthernet} <PORT0_ID>