![Planet Networking & Communication MGSW-28240F Скачать руководство пользователя страница 238](http://html.mh-extra.com/html/planet-networking-and-communication/mgsw-28240f/mgsw-28240f_command-manual_1563905238.webp)
Command Guide of MGSW-28240F
lb
Loop Back
<Prio : 0-7>
Priority in case of tagged OAM. In the EVC domain this is the COS-ID.
count
The number of LBM PDU to send in one loop test. The value 0 indicate infinite transmission (test behavior). This
is HW based LBM/LBR and Requires VOE.
<Count : uint>
Number of LBM PDU to send value
size
The number of bytes in the LBM PDU Data Pattern TLV
<size>
The LBM frame size. This is entered as the wanted size (in bytes) of a un-tagged frame containing LBM OAM
PDU - including CRC (four bytes). Example when 'Size' = 64 => Un-tagged frame size = DMAC(6) + SMAC(6) +
TYPE(2) + LBM PDU LENGTH(46) + CRC(4) = 64
interval
The number of bytes in the LBM PDU Data Pattern TLV
<interval>
The interval between transmitting LBM PDU. in case 'count' != 0 this is in 10ms and max is 100. In case
'count' == 0 this is in 1us and max is 10.000.
dei
Drop Eligible Indicator in case of tagged OAM
.
multi
OAM PDU is transmitted with multicast MAC.
uni
OAM PDU is transmitted with unicast MAC. The MAC is taken from
peer MEP MAC database.
mac
Loop Back unicast MAC to be used in case of LB against MIP.
<Mac : mac_addr>
Loop Back target unicast MAC value
mep-id
Peer MEP-ID for unicast LB. The MAC is taken from peer MEP MAC database.
<Mepid : uint>
Peer MEP-ID value
Default:
None
Usage Guide:
To configure
Loop Back
of
MEP
.
Example:
To configure
Loop Back
of
MEP 2
as below table
Switch# configure terminal
Switch (config)#
mep 2 lb 1 dei count 10 size 64 interval 100