![Planet Networking & Communication MGSW-28240F Скачать руководство пользователя страница 245](http://html.mh-extra.com/html/planet-networking-and-communication/mgsw-28240f/mgsw-28240f_command-manual_1563905245.webp)
Command Guide of MGSW-28240F
one-zero
Test pattern is set to 10101010.
rate
The TST frame transmission bit rate - in Mega bits pr. second. Limit on Caracal is 400 Mbps. Limit on Serval is
1Gbps. This is the bit rate of a standard frame without any encapsulation. If 1 Mbps rate is selected in a EVC
MEP, the added tag will give a hi
<Rate : uint>
Transmission rate value
size
The TST frame size. This is entered as the wanted size (in bytes) of a un-tagged frame containing TST OAM PDU
- including CRC (four bytes). Example when 'Size' = 64 => Un-tagged frame size = DMAC(6) + SMAC(6) +
TYPE(2) + TST PDU LENGTH(46) + CRC(4) = 64
<Size : uint>
Frame size value
Default:
Usage Guide:
To enable
Test Signal
of
MEP
.
Example:
To enable
Test Signal
of
MEP 1
as below table
Switch# configure terminal
Switch (config)#
mep 1 tst 3 dei mep-id 2 sequence one-zero rate 10 size 68
4.2.135 mep <Instance> up
Command:
mep <Instance> [mip]
up domain { port | evc | vlan } [ vid <vid> ] flow <flow> level
<level> interface <port_type> <port>
mep
Maintenance Entity Point
<Instance>
The MEP instance number.
mip
This MEP instance is a half-MIP
up
This MEP is a Up-MEP
domain
The domain of the MEP
evc
This MEP is a EVC domain MEP.
port
This MEP is a Port domain MEP.
vlan
This MEP is a VLAN domain MEP.
flow
The flow instance that the MEP is related to.
-245-