User’s Manual of MGSW-MGSD Series
10Gbps SFP+ (10GBASE-BX, Single Fiber Bi-directional SFP)
Model
Speed (Mbps)
Connector
Interface
Fiber Mode Distance
Wavelength (TX)
Wavelength (RX)
Operating Temp.
10G
WDM(LC) Single Mode
20km
1270nm
1330nm
0 ~ 60 degrees C
MTB-LA20
MTB-LB20
10G
WDM(LC) Single Mode
20km
1330nm
1270nm
0 ~ 60 degrees C
10G
WDM(LC) Single Mode
40km
1270nm
1330nm
0 ~ 60 degrees C
MTB-LA40
MTB-LB40
10G
WDM(LC) Single Mode
40km
1330nm
1270nm
0 ~ 60 degrees C
10G
WDM(LC) Single Mode
60km
1270nm
1330nm
0 ~ 60 degrees C
MTB-LA60
MTB-LB60
10G
WDM(LC) Single Mode
60km
1330nm
1270nm
0 ~ 60 degrees C
1. It is recommended to use PLANET SFP/SFP+ on the
Managed Switch
. If you insert an
SFP/SFP+ transceiver that is not supported, the
Managed Switch
will not recognize it.
2. Please choose the SFP/SFP+ transceiver which can be operated under -40~75 degrees C
temperature if the switch device is working in a 0~50 degrees C temperature environment.
1.
Before we connect the MGSW-MGSD series to the other network device, we have to make sure both sides of the SFP
transceivers are with the same media type, for example, 1000BASE-SX to 1000BASE-SX, 1000Bas-LX to 1000BASE-LX.
2.
Check whether the fiber-optic cable type matches with the SFP transceiver requirement.
To connect to 1000BASE-SX SFP transceiver, please use the multi-mode fiber cable with one side being the male
duplex LC connector type.
To connect to 1000BASE-LX SFP transceiver, please use the single-mode fiber cable with one side being the male
duplex LC connector type.
Connect the Fiber Cable
1.
Insert the duplex LC connector into the SFP/SFP+ transceiver.
2.
Connect the other end of the cable to a device with SFP/SFP+ transceiver installed.
3.
Check the LNK/ACT LED of the SFP/SFP+ slot on the front of the Managed Switch. Ensure that the SFP/SFP+
transceiver is operating correctly.
4. Check the Link mode of the SFP/SFP+ port if the link fails. To function with some fiber-NICs or Media Converters, user has
to set the port link mode to
“10G Force”
,
“1000M Force”
or
“100M Force”
.
2.3.2 Removing the Module
1.
Make sure there is no network activity by checking with the network administrator, or through the management interface of
the switch/converter (if available) to disable the port in advance.
2.
Remove the Fiber Optic Cable gently.
3.
Lift up the lever of the MGB module and turn it to a horizontal position.
4.
Pull out the module gently through the lever.
39
Содержание MGSD-10080F
Страница 1: ...User s Manual of MGSW MGSD Series 1 ...
Страница 107: ...User s Manual of MGSW MGSD Series Figure 4 4 6 Mirror Configuration Page Screenshot 107 ...
Страница 286: ...User s Manual of MGSW MGSD Series Figure 4 12 1 Port Limit Control Configuration Overview Page Screenshot 286 ...
Страница 297: ...User s Manual of MGSW MGSD Series Figure 4 12 8 DHCP Snooping Configuration Screen Page Screenshot 297 ...
Страница 332: ...User s Manual of MGSW MGSD Series Figure 4 15 3 Remote IP Ping Test Page Screenshot 332 ...