![Planet Networking & Communication MGSD-10080F Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/planet-networking-and-communication/mgsd-10080f/mgsd-10080f_user-manual_1563904012.webp)
User’s Manual of MGSW-MGSD Series
Digital Input and Digital Output for External Alarm
PLANET MGSW-MGSD series supports Digital Input, and Digital Output on the front panel. This external alarm offers
technicians the ability to use Digital Input to detect and log external device status (such as door intrusion detector) for the alarm.
Digital Output could be used to alarm if the MGSW-MGSD series has port link down, link up or power failure.
AC and DC Redundant Power to Ensure Continuous Operation
PLANET MGSW-MGSD series is equipped with one
100~240V AC
power supply unit and one additional
36 ~ 60V
DC
power
supply unit for redundant power supply installation. A redundant power system is also provided to enhance the reliability with
either the 100~240V AC power supply unit or the DC 36 ~ 60V power supply unit. Redundant Power Systems are specifically
designed to handle the demands of high tech facilities requiring the highest power integrity. Furthermore, with the 36~ 60V DC
power supply implemented, the MGSW-MGSD series can be applied as the telecom level device that could be located in the
electronic room.
Optimized Design for Metropolitan Area Network Redundant Ring with Fast Recovery
The MGSW-28240F and MGSD-10080F support redundant ring technology and features strong rapid self-recovery capability to
prevent interruptions and external intrusions. It incorporates
ITU G.8032 Ethernet Ring Protection Switching
technology,
Spanning Tree Protocol (802.1w RSTP), and redundant power supply system into customer’s industrial automation network to
enhance system reliability and uptime in harsh environments. The MGSW-28240F and MGSD-10080F also protects customer’s
metro Ethernet network connectivity with switching recovery capability that is used for implementing fault tolerant ring and mesh
network architectures. If the metro Ethernet network was interrupted accidentally, the fault recovery times could be less than
50ms to quickly bring the network back to normal operation.
12
Содержание MGSD-10080F
Страница 1: ...User s Manual of MGSW MGSD Series 1 ...
Страница 107: ...User s Manual of MGSW MGSD Series Figure 4 4 6 Mirror Configuration Page Screenshot 107 ...
Страница 286: ...User s Manual of MGSW MGSD Series Figure 4 12 1 Port Limit Control Configuration Overview Page Screenshot 286 ...
Страница 297: ...User s Manual of MGSW MGSD Series Figure 4 12 8 DHCP Snooping Configuration Screen Page Screenshot 297 ...
Страница 332: ...User s Manual of MGSW MGSD Series Figure 4 15 3 Remote IP Ping Test Page Screenshot 332 ...