Getting Started

14

RS232 / RS485 Connections

The 

kryo-connect 

is provided with a 9 way D-Type plug that can be

configured for both RS232 and RS485 interfaces.  The actual configuration is
determined by dip-switches inside the unit and is normally factory
configured.  The information below can be used if the configuration needs to
be changed or if interconnecting cables need to be made.

It is important that the kryo-connect is connected to ground to
prevent charge build up.  On RS232 connections this is achieved
through the cable screen and signal ground.  On RS485
connections, if no ground is provided through the cable, the

chassis ground 

 should be connected to a suitable ground

reference.

Pin outs

Port type

DIP switch *

1

2

3

4

5

6

7

8

9

RS232 –

Wired as

DTE.

Requires null
modem cable

to connect to a

PC

-

R

X

T

X

-

G
N

D

-

R
T

S

C
T

S

-

RS485 full

duplex

tx

-

rx

-

tx

+

rx

+

RS485 Half

duplex

A

-

B

+

RS485

terminate RX

120 Ohms

Connects a 120 Ohm resistor across the RX

pair

RS485

terminate TX

120 Ohms

Connects a 120 Ohm resistor across the TX

pair

* grey switches means the setting does not matter or is determined by another
requirement such as termination

Содержание kryo connect

Страница 1: ...kryo connect Getting Started MA009170 issue 004...

Страница 2: ...and or other countries Java is a trademark or registered trademark of Sun Microsystems Inc in the United States and other countries IBM is a trademark or registered trademark of IBM Corporation in th...

Страница 3: ...o the network 6 Preparing for Configuration 7 Starting kryo connect Configurator software 8 On a PC running Windows 32 8 On a PC running Linux 8 Running kryo connect Configurator 9 Starting the web se...

Страница 4: ...ilure to follow these instructions could result in personal injury Ethernet 10 base T socket Chassis terminal DC power inlet socket Centre positive RESET Reset switch Press to reset the unit This will...

Страница 5: ...mation purposes only and must not be the sole means of monitoring alarm and fault conditions Introduction The kryo connect is a small desktop or wall mounted unit designed to convert an existing devic...

Страница 6: ...r network and accessible through your web browser you will be able to access the online manual from the unit s home page This manual provides details on how to connect the unit to your network so that...

Страница 7: ...100m 330 feet of the unit Client PC Microsoft Internet Explorer v6 with cookies enabled and Java Virtual Machine VM installed Administrator s PC Please note that this PC is only required when first c...

Страница 8: ...as there may be additional installation requirements that need to be considered Locate the RJ45 network connector located in the end panel of the web server RJ45 network connector If you are connectin...

Страница 9: ...n place Plug the power supply into an easily accessible mains power socket located close to the kryo connect The power supply provided is suitable for connection to an IT power distribution system Plu...

Страница 10: ...rights to install the program The CD should start the installation program automatically If the program does not start click on the Start button on the Windows task bar Select Run from the menu Click...

Страница 11: ...ork Mask The network mask allows the unit to determine whether it is a local device The correct setting for this parameter requires knowledge of the actual network system Default Gateway When a user a...

Страница 12: ...of MANAGER1 with a password of password NB the name and password are both case sensitive Select the User guide button from the main Welcome page and follow the instructions for setting up the unit and...

Страница 13: ...ion Details As you follow the instructions in this guide you should also complete the details of your kryo connect in the table below Serial number IP Address Network Mask Default Gateway DNS Server U...

Страница 14: ...ing Started 12 Contact Details Technical support E mail support planer co uk Telephone 44 0 1932 755006 Fax 44 0 1932 755001 Sales E mail sales planer co uk Telephone 44 0 1932 755005 Fax 44 0 1932 75...

Страница 15: ...h the clip downwards Standard Patch Cable Pin Colour 1 White Green White Green 2 Green Green 3 White Orange White Orange 4 Blue Blue 5 White Blue White Blue 6 Orange Orange 7 White Brown White Brown 8...

Страница 16: ...up On RS232 connections this is achieved through the cable screen and signal ground On RS485 connections if no ground is provided through the cable the chassis ground should be connected to a suitabl...

Страница 17: ...may be transferred to and then utilised on another machine provided that the Software is removed from the original machine ii The Software may be accessed concurrently via a network by any number of u...

Страница 18: ...T as expressly stated herein the Software is provided and licensed without warranty either express or implied including but not limited to any implied warranties in respect of merchantability or fitne...

Страница 19: ...the License to be otherwise enforceable If in Planer plc s opinion such deletion unreasonably compromises its rights Planer plc reserves the right to terminate the License and refund the fee paid by...

Страница 20: ...0 web server TCP IP UDP ICMP External Dimensions 115mm x 83mm x 35mm Weight 0 23kg Power supply External dimensions 30mm x 45m x 85mm excluding mains socket adaptor DC cord length 1 8m Connector 2 1mm...

Страница 21: ...Getting Started 19 This page left deliberately blank...

Страница 22: ...Getting Started 20 This page left deliberately blank...

Страница 23: ......

Отзывы: