Planar Systems (Planar) warrants that the goods sold hereunder will be free of
defects in materials and workmanship, and such goods will substantially conform
to the specifications furnished by Planar, and to any drawings or specifications
furnished to Planar by the Buyer if approved by Planar. This warranty shall be
effective only if Planar receives notice of such defect or nonconformance during
the period of the warranty. Planar's sole and exclusive liability for breach of
warranty shall be, at Planar's option, to repair or replace the Planar product(s)
with refurbished units or provide a credit to buyer in the amount of the purchase
price.

Commencement and Duration of Warranty

The warranty period begins on the date of shipment from Planar. The goods sold
hereunder are warranted for a period of eighteen months from date of shipment
unless otherwise agreed to by Buyer and Planar.  No extension of the warranty
will be given during the time the goods are in Planar’s possession.

Place of Repair or Replacement

In order to obtain service under this warranty, Buyer must notify Planar of the
defect before expiration of the warranty period, and request a “Return Material
Authorization Number.” If the configuration has been modified in any manner,
the product must be returned to its original configuration before any warranty
service will be performed by Planar. No goods are to be returned to Planar
without prior authorization.  Buyer will be responsible for packaging and
shipping the defective goods to the Planar Service Facility located at Beaverton,
Oregon, with shipping charges prepaid.

Limitation of Warranty

The foregoing warranty shall not apply to defects resulting from (a) improper or
inadequate maintenance by Buyer; (b) unauthorized modification of the goods;
(c) operation of the goods outside of the environmental specifications of the
goods; (d) neglect, misuse or abuse of the goods; or (e) modification or
integration with other goods not covered by Planar's warranty when such
modification or integration increases the likelihood of damage to the goods.

THE WARRANTY IS GIVEN BY PLANAR IN LIEU OF ANY OTHER
WARRANTIES, EXPRESS OR IMPLIED. PLANAR DISCLAIMS ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. PLANAR’S RESPONSIBILITY TO REPAIR OR REPLACE
DEFECTIVE PRODUCTS IS THE SOLE AND EXCLUSIVE REMEDY
PROVIDED TO THE BUYER FOR BREACH OF THIS WARRANTY. PLANAR
WILL NOT BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES IRRESPECTIVE OF WHETHER PLANAR HAS
ADVANCE NOTICE OF THE POSSIBILITY OF SUCH DAMAGES.

Содержание VitalScreen D6015TM

Страница 1: ...The Definition of Quality D6015TM SERIES MEDICAL MONITOR D6015TM 15 XGA D6015TM TS 15 XGA SAW TOUCHSCREEN D6015TM TR 15 XGA RESISTIVE TOUCHSCREEN Operations Manual...

Страница 2: ...g Systems are registered trademarks of GCX Corporation All other trademarks are the property of their respective owners This document is subject to change without notice Planar provides this informati...

Страница 3: ...The Display Controls 13 Adjusting the Medical Monitor s Display 14 On Screen Display Lockout 14 OSD Main Menu 15 Quick Adjustment Functions 17 Power Switch 17 Technical Information 18 Planar D6015TM...

Страница 4: ...gure 4 Screen Angle Settings 10 Figure 5 Connecting Power to the Monitor 10 Figure 6 Connecting the Monitor to Your System 11 Figure 7 Connecting the Stereo Speakers 11 Figure 8 Monitor Display Contro...

Страница 5: ...reatly reducing the radiation related health concerns associated with CRT monitors Functional Description The Planar D6015TM Series Medical Monitor consists of a low profile molded plastic monitor hea...

Страница 6: ...des cleaning with a damp wrung out mild soapy cloth Protection from various chemicals used for cleaning and protection from liquids consistent with these cleaning procedures is provided in accordance...

Страница 7: ...rd or cable is frayed or damaged immediately replace it with a another of the same type and rating as supplied by Planar See Ordering Information for part numbers Safety and regulatory listings and ce...

Страница 8: ...lass B computing devices in a typically configured system It is the system integrator or configurer s responsibility to test and ensure that the entire system complies with applicable EMC laws Planar...

Страница 9: ...an only be accomplished in the configured medical device or system and is the responsibility of the device or system manufacturer Planar has the necessary documentation such as IEC 60601 1 notified bo...

Страница 10: ...contact customer service for assistance Keep all packing material in case you need to ship or store the monitor in the future or in case of return After you unpack the monitor make sure the following...

Страница 11: ...nd lower button to increase or decrease the setting of the selected function See Quick Adjustment Functions on page 17 for additional features of these buttons 4 Power Switch On Screen Display OSD Pus...

Страница 12: ...for Optional Touchscreen Connect the cable provided with the touchscreen package to this port and to your system s 9 pin serial port 4 Audio Line in Port Connect the system s audio line out to this p...

Страница 13: ...nload Drivers page select the appropriate platform and download the driver file and the instruction file Following driver software installation you will need to calibrate your touchscreen to the compu...

Страница 14: ...the female end of the mains AC power cord into the AC power adapter then plug the power connector of the adapter into the power port on the monitor The port 12 Vdc is located at the rear of the monito...

Страница 15: ...until it receives a video signal from the system Connecting Optional Stereo Speakers Connect the supplied audio cable to the line out port of your computer s audio card Next connect the other end of t...

Страница 16: ...signal as shown in the table below Mode DC Input Power monitor only AC Input Power incl AC adapter LED Status On with audio On without audio 30 0 W max 28 0 W max 40 W max 37 W max Steady Green Steady...

Страница 17: ...es Medical Monitor are five buttons for operating the monitor and accessing the functions on the On Screen Display OSD Button 1 Function select up 2 Function select down 3 Adjustment increase 4 Adjust...

Страница 18: ...uick and easy When the OSD is on use the Function buttons and to scroll through the menu items Use the Adjustment buttons and to advance to the next sub menu and make changes to the selected menu item...

Страница 19: ...Change display size position clock and phase etc AUTO ADJUST Automatically adjust the picture quality and alignment It is recommended you use this function in Windows or similar environments this func...

Страница 20: ...o 6500 Kelvin USER Enable the User Color field and adjust individual RGB levels TO MAIN MENU Return to Main Menu Miscellaneous Menu AUDIO VOLUME Adjust the audio volume of the monitor s speakers on mo...

Страница 21: ...ness icon Use the Adjustment buttons to increase or decrease the Brightness level Press the upper or lower Adjustment button or to enable the small Volume icon Use the Adjustment buttons to increase o...

Страница 22: ...VGA compatible analog RGB 15 pin D Sub Separate Sync Composite Sync Scanning Frequency 24 61 kHz horizontal 50 90 Hz vertical Factory Preset Modes 25 Power Management Meets VESA DPMS EPA Power Consump...

Страница 23: ...NEC PC98 400 105 640x400 31 500 70 150 25 197 NEC PC98 400 106 640x350 31 469 70 087 25 175 VGA 350 107 640x350 37 861 85 080 31 500 VESA 350 108 640x480 31 469 59 940 25 175 VGA 480 109 640x480 35 00...

Страница 24: ...alent Description Pin Pin Description Red Video 1 9 NC Green Video 2 10 Logic Ground Blue Video 3 11 NC NC 4 12 SDA DDC1 2B Logic Ground 5 13 H sync Red Video Ground 6 14 V sync Green Video Ground 7 1...

Страница 25: ...Operations Manual OM700 02 21 Mechanical Outline Drawings All dimensions shown in the following drawings are specified in millimeters Figure 11 GCX VESA Mounting Option...

Страница 26: ...22 Operations Manual OM700 02 Figure 12 Desk Stand Option Figure 13 Display Front...

Страница 27: ...lay for more information PROBLEM Display is Unclear and Unstable It is best to adjust the display using an image of vertical lines In Windows load a wallpaper bitmap that has vertical lines in it or y...

Страница 28: ...sistance 3 Turn the monitor off and then turn it back on again Press the upper Function button once and then press the upper Adjustment button several times If there is still no display press the lowe...

Страница 29: ...st a Return Material Authorization Number If the configuration has been modified in any manner the product must be returned to its original configuration before any warranty service will be performed...

Страница 30: ...vice If your Medical Monitor needs service call Planar Customer Service at 1 503 690 6960 between 7 00 a m and 4 00 p m PST Monday through Friday or fax to 1 503 748 7085 You will need the unit s seri...

Страница 31: ...ical Monitor Resistive Touchscreen D6015TM TR 15 Inch XGA Medical Monitor Resistive w deskstand 996 0431 00 996 0432 00 996 0435 00 996 0436 00 996 0433 00 996 0434 00 Planar power adapter model PPA45...

Страница 32: ......

Страница 33: ...OR 97006 1992 Tel 1 503 690 1100 Fax 1 503 690 1493 sales planar com app_eng planar com Planar Systems Inc Olarinluoma 9 P O Box 46 FIN 02201 Espoo Finland Tel 358 9 420 01 Fax 358 9 420 0200 intlsal...

Отзывы: